AREA CLASSIFICATION
Area Classification ___________________________ US/Canada:
Class I, Division 1, Groups B-D, T4
Class I Zone 0/1, AEx ia op is/db IIB+H2 T4 Ga/Gb
Ex ia op is/db IIB+H2 T4 Ga/Gb
-20°C
≤
Tamb
≤
+65°C
IECEX:
Ex ia op is/db IIB+H2 T4 Ga/Gb
-20°C
≤
Tamb
≤
+65°C
ATEX:
II 1/2 G Ex ia op is/db IIB+H2 T4 Ga/Gb
-20°C
≤
Tamb
≤
+65°C
UKCA
Ex ia op is/db IIB+H2 T4 Ga/Gb
-20°C
≤
Tamb
≤
+65°C
Environmental Conditions_______________________OVII, PD2, Wet Location
POWER
Requirements ______________________________ 10 – 24 VDC, Um 24 VDC, 1.00 A max
100 – 240 VAC, 50/60Hz, Um 240 VAC, 500 mA max
Use only approved Class 2 or limited energy circuits