TROUBLESHOOTING
e-mail. [email protected]; [email protected]; website: www.amfreece.com
Phone: +420 582 309 286; Fax: +420 582 360 606
Released 05/2010
2. E R R O R M E S S A G E S O F T H E C O N T R O L P A N E L D I S P L AY
SYMPTOM
POSSIBLE CAUSE
PROBABLE SOLUTION
Low air pressure
Emergency stop
Service mode
Low voltage
Motor isn‘t ready
Hand valve of the regulator
switched off - it assembled
The air pressure in the air
supply piping below 0.5 MPa
Emergency Stop button is
switched on
The machine is in the operation
mode, motor is disconnected
The power supply is below
185V - relay HRN-35 is
installed
The power supply is below
185V - relay HRN-35 is not
installed
Open the hand valve
Increase the air pressure
Release the Emergency Stop
button and press F6 key on the
control panel
Press F6 key on the control
panel
Call electroengineer in a plant
Call electroengineer in a plant