S-4000 LT
1-20
Revised 10/2004
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
5 . T E S T S
WARNING! ONLY PROFESSIONAL SERVICE TECHNICIANS SHOULD PERFORM THESE TESTS!
The main screen appears on the display. Press
,
appears on the display.
To enter the tests menu, press
key. The follwing screen appears on the display
. To scroll this menu down, press
key, to scroll this menu up, press
key.
NOTE:
Before performing the tests, press and release the Emergency Stop button to disconnect the motor.
INPUTS
1.
Z-phase Pls
-
Z-phase Pls off
appears on the display. Very slowly rotate the handwheel.
When the z-phase pulse is activated, the
Z-phase Pls on
appears on the display.
Servo S1 is tested by this parameter.
2.
Home senzor
-
the end position sensor.
Home sensor off
appears on the display. Activate the
sensor using a metal tool.
Home sensor on
appears on the display. Switch BQ1 is
tested by this parameter.
3.
Voltage Rly
-
Voltage Rly off
appears on the display. If the power supply drops below 165 V,
the
Voltage Rly on
appears on the display. Relay VC 1 min is tested by this
parameter.
4.
Pedal 1 step
-
Pedal 1 step off
appears on the display. When the foot pedal is pressed to its first
position, the
Pedal 1 step on
appears on the display. Switch SB4 is tested by this
parameter.
5.
Pedal 2 step
-
Pedal 2 step off
appears on the display. When the foot pedal is pressed to its
second position, the
Pedal 2 step on
appears on the display. Switch SB5 is tested
by this parameter.
6.
Em Stop
-
after the Emergency Stop button is pressed, the
Em Stop off
appears on the
display. After the Emergency Stop button is released, the
Em Stop on
appears
on the display. Switch SA1 is tested by this parameter.
7.
Clamp Button
-
Clamps button off
appears on the display. When the clamp Up/Down button is
pressed, the
Clamp button on
appears on the display. Switch SB3 is tested by this
parameter.
D - MACHINE CONTROLS