Page 3–32
UPLC™ Application Manual
Figure 3–29c. GE T
ype EM Relays with UPLC™
.
U
P
L
C
T
e
rm
in
a
ls
Jumper
T
able
T
B
1
-1
(D
C
)
T
B
1
-3
(A
U
X
+
)
T
B
3
-4
(
S
T
O
P
)
T
B
3
-3
(L
L
)
T
B
3
-5
(
S
T
A
R
T
)
T
B
1
-4
(A
U
X
-)
T
B
4
-
5
(O
U
T
P
U
T
)
T
B
4
-1
0
(O
U
T
P
U
T
)
T
B
3
-8
(L
L
)
T
B
3
-9
(
S
T
O
P
)
T
B
1
-2
(D
C
)
T
B
3
-1
0
(
S
T
A
R
T
)
C
h
a
s
s
is
G
ro
u
n
d
UPLC
Universal
Power
Line
Carrier
B
A
T
T
E
R
Y
P
O
S
IT
IV
E
C
A
R
R
IE
R
S
T
O
P
+
R
R
A
M
A
C
A
R
R
IE
R
L
O
W
L
E
V
E
L
T
E
S
T
C
A
R
R
IE
R
H
IG
H
L
E
V
E
L
T
E
S
T
C
A
R
R
IE
R
S
T
A
R
T
B
A
T
T
E
R
Y
N
E
G
A
T
IV
E
C
A
R
R
IE
R
A
U
X
.
R
E
L
A
Y
0
–
3
0
m
A
0
–
3
0
0
m
A
Module
Function
Software
Selection
Hardware
Selection
Label
on
board
Recommendation
Backplane
Coax
Setting
2
wire/4
wire
JMP3/JMP5
2
Wire
#o
fP
A
s
1P
A/2P
A
JMP2/JMP6
Per
factory
Coax
Impedance
50/75
ohms
JMP1/JMP4
50
ohms*
Power
Supply
Power
PwrOn/
PwrOf
f
JMP3
PwrOn
Alarm
Contact
NO/NC
JMP1/JMP2
Per
Engineering
Aux
Power
Supply
Holding
current
20
mA/200
mA
8V(200
mA)
or
46/20V(20
mA)
JMP1/JMP2
Per
carrier
relay
requirement
(JMP3
is
used
only
for
46/20V
outputs
when
JMP1/JMP2
is
in
46/20V
position)
Input/Output
Input
1
Carrier
Start
Removal
of
V
oltage
15/48/125/250
Vdc
Input
1
Station
Battery
Input
2
Carrier
Stop
Application
of
V
oltage
15/48/125/250
Vdc
Input
2
Station
Battery
Input
3
Low
Level
Key
Removal
of
V
oltage
15/48/125/250
Vdc
In
put
3
Station
Battery
Input
4
15/48/125/250
Vdc
Input
4
Per
Engineering
Input
5
15/48/125/250
Vdc
Input
5
Per
Engineering
LL
Output
1
Blcoking
NO
0.1/1.0
A
LLO1
1.0
A
LL
Output
2
0.1/1.0
A
LLO2
Per
Engineering
LL
Output
3
0.1/1.0
A
LLO3
Per
En
gineering
LL
Output
4
0.1/1.0
A
LLO4
Per
Engineering
LL
Output
5
0.1/1.0
A
LLO5
Per
Engineering
LL
Output
6
0.1/1.0
A
LLO6
Per
Engineering
LL
Output
7
0.1/1.0
A
LLO7
Per
Engineering
LL
Output
8
NO/NC
LLO8
Per
Engineering
LL
Output
9
NO/NC
LLO9
Per
Engineering
LL
Output
10
General
Alarm
NO
NO/NC
LLO10
Per
Engineering
*O
r
per
engineering
’s
recommendation
Inputs
Carrier
Start
Carrier
Stop
Low
Level
IN
1
IN
2
IN
3
IN
4
4
IN
5
Low
Level
Outputs
TB5-10
TB5-9
TB5-8
TB5-7
TB5-6
TB5-5
TB5-4
TB5-3
TB5-2
TB5-1
TB1-6
TB1-5
TB4-10
TB4-9
TB4-8
TB4-7
TB4-6
TB4-5
TB4-4
TB4-3
TB4-2
TB4-1
TB3-10
TB3-9
TB3-8
TB3-7
TB3-6
TB3-5
TB3-4
TB3-3
TB3-2
TB3-1
Gen
Alarm
PS
Alarm
LL
Blocking
Output
01
LL
02
LL
03
LL
04
LL
NOTES:
1.
All
contacts
are
link
selectable
for
normally
open
or
closed.
05
LL
06
LL
07
LL
08
LL
09
LL
10
Summary of Contents for UPLC CU44-VER04
Page 2: ......
Page 20: ...Page 2 4 UPLC Application Manual Figure 2 3 Chassis Dimensions ...
Page 78: ...Page 4 2 UPLC Application Manual USER NOTES ...
Page 126: ...Page 8 16 UPLC Application Manual USER NOTES ...
Page 129: ......