Installation, Operation and Maintenance Manual
OXYvisor Optical Oxygen Analyzer
5.10 Overall Menu Flowchart
Figure 29 - Programming Menu Flowchart
Measurement
& Units
Oxygen
Sensor Type
BOS1
BOS2
BOS3
User Defined
Constants
f1
dPhi1
dPhi2
dKsv1
dKsv2
m
Media
Gas Phase Oxygen
Measurement
Aqueous Liquids
(Contains Water)
Non-Aqueous Liquids
(No Water)
Humidity Present (> 50%)
Std Pressure Compensation
(Ideal Gas Law)
**AGI Compressibility
(Natural Gas Only)
**Equations of State
Correction For Dissolved Salts
ppm Oxygen (gas)
%Oxygen (gas)
Oxygen Units
hPa (gas)
% Air Saturation (gas)
Compensation Units
Temperature Units
Process Pressure Units
(Absolute)
Non-Compressible Liquids
Fahrenheit
Celsius
mBar
inches H2O
Bar
Torr
PSI
Oxygen
Sample Rate
Auto Adjust
Manual
Adjust
Normal Sample Rate
Max Sample Rate
Change for Max Sample Rate
10 - 100%
*Automatic
*Manual Adjust
*Pulse Length
Signal
Intensity
Salinity Concentration Input
ppm Oxygen (Liquid)
ppb Oxygen (Liquid)
hPa (gas)
**Compressible Liquids
** Only Accessible in Software
* Only accessible in advanced
Calibration
Basic Setup
Advanced
Setup
Factory O2
Sensor
Calibration
Last Cal
Status
Enter Zero Phase Angle
Enter Span Calibration Point
Enter Span Cal Phase Angle
Enter Calibration Temperature
Enter Atmospheric Pressure
Send Factory Cal Data
Manual O2
Calibration
Cal-Temp On
Cal-Temp Off
Enter Temp
Single Point Calibration
Two Point Calibration
Zero Gas Calibration
Span Gas Calibration
Input Span
Gas
Zero Gas Calibration
Span Gas Calibration
Input Span
Gas
Is Humidity Present During Cal
Use Ambient Pressure Sensor
Manual Pressure Input
*Auto O2
Calibration
Setup
Description
Schedule (1
st
, 2
nd
, 3
rd
, 4
th
)
Calibration
Yes / No
Calibration
Frequency
Calibration Time and Interval Time Calibration Should Occur
Time Calibration Should Occur
Interval Between Calibrations
Time to Next
Calibration
Is Humidity Present During Cal
Use Ambient Pressure Sensor
Manual Pressure Input
Enter Span Gas Value
Zero Cal Drift Tolerance
Span Cal Drift Tolerance
Zero Gas Purge Time
Span Gas Purge Time
Calibration Recovery Time
Enable Auto Calibration
*Initiate O2
Auto
Calibration
Start Auto Calibration – 1
st
Time
Start Auto Calibration
Press Esc to Stop AutoCal
*Temperature
Sensor
Calibration
PT100 / PT1000 RTD
Calibration
Pressure Sensor Analog Input
Calibration
*Pressure
Sensor
Calibration
Ambient Temperature Sens
Calibration
OR
* Only accessible in advanced
Error Log
Data Log
.csv File
.txt Delimited File
Data Trend
Setup
Stop data logging
Start data logging
Datalogging
Status
Download
Log File
Last 10 errors
Calibration
Log
Parameter to
log
Signal Intensity
Phase Angle
Oxygen
Process Temperature
Process Pressure
Section 5
Operations