TROUBLESHOOTING
9-2 April 3, 2000
Charging current much less than DC Max Amps stamped on charger data plate.
Battery is nearly fully charged.
Charger is performing properly.
Charger set for wrong AC input service – 208/240 or 220/380 volts input models only – see AC input
volts information on charger data plate.
Reconnect as described in the INSTALLATION chapter of this manual.
Battery is sulfated or has developed high resistance connection (s).
Have battery serviced by a qualified service person.
Defective charger.
Have charger serviced by an authorized service person.
Charging current much greater than DC Max Amps stamped on charger data plate.
Battery number of cells less than no. cells stated on charger data plate. (e.g.; A 6 cell battery has
been connected to a 12 cell charger.
Connect battery to properly sized charger.
Charger set for wrong AC input service – 208/240 or 220/380 volts input models only – see AC input
volts information on charger data plate.
Reconnect as described in the INSTALLATION chapter of this manual.
Battery is defective.
Have battery serviced by a qualified service person.
Branch AC power circuit protection operates repeatedly. (Fuse (s) “blow” or circuit
breaker trips repeatedly.)
Branch circuit protection and/or wiring not rated for charger requirements as stated on charger data
plate.
Have a qualified electrician review the branch circuit installation.
Branch circuit, circuit breaker defective.
Have a qualified electrician replace circuit breaker.
Defective charger.
Have charger serviced by an authorized service person.