temperature Measurement
Measure temperature from -40
°
F to 1832
°
F (-40
°
C to 1000
°
C).
1. Connect red (+) end of Thermocouple
(included) to the
V
Ω
Hz input
Jack and the black (-) end to
the
mAμA
input
Jack.
2. Turn Rotary Switch to the
°c°F
position. The Display will show the
current ambient temperature.
3. Press
Blue
Button to switch
between Celsius and Fahrenheit.
4. Touch the tip of the Thermocouple
to the object being tested.
5. After a few seconds the measured
temperature will display.
6. When testing is complete, turn
Rotary Switch to
OFF
, remove
Thermocouple and store with Meter.
note:
To avoid measurement errors at
very low temperatures, the operating
temperature must not exceed 10~28°F
.
WarninG!
to prevent electric
shock, remove thermocouple before
switching between testing modes.
resistance Measurement
Measure resistance up to 60M Ohms.
WarninG!
to prevent electric shock,
turn off all power and fully
discharge capacitors in the circuit
under test before measuring.
note:
When measuring Ohms,
start with the lowest range if the
resistance is unknown.
1. Plug black test lead into
cOM
Jack.
Plug red test lead into
V
Ω
Hz
input
Jack.
2. Turn the Rotary Switch to
the
position.
3. Press Blue Button until the Display
indicates Ohms
Ω
is being measured.
4. Carefully touch exposed
conductors with tips of probes.
5. Read measured resistance
on the Display.
6. When testing is complete, turn
Rotary Switch to
OFF
, remove
Test Leads and store with Meter.
note:
Sometimes the resistor value and
measured resistance differ. This is due
to the Meter’s output test current going
through all possible paths between leads.
• Keep test leads as
short as possible.
• Resistors should be
measured out of circuit.
note:
For resistance measurements
above 1MΩ, allow a few seconds
to get a steady reading.
note:
When leads are disconnected
or measurement is out of
range,
OL
is displayed.