1 Installation
1.1
Unpacking Filter System
NOTE: Filter components may be attached to sides of crate or packed in boxes within
shipping crate. Be sure to remove all components before disposing of crate.
DO NOT LIFT OR PULL FILTER VESSELS BY SIDE PORTS; INTERNAL COMPONENTS MAY BE
DAMAGED!
a) Inspect shipping crate(s) and packages for damage. Before signing bill of lading,
report any damage to AmeriWater 800.535.5585.
b) Remove top of crate then break down sides as necessary to remove contents.
Report any damage immediately to AmeriWater 800.535.5585l
c) Unpack filter system as close as possible to installation location.
d) Flange gaskets, bolts, and pipe stand hangers (if applicable) are contained in
cardboard boxes packed in crate(s).
1.2
Rigging
a) Pallets should be lifted by a forklift or crane. Filter systems should be rigged
from lift points.
Do not allow rigging straps to contact system components.
1.3 Locating Filter System
a) Filter should be located on a level floor or housekeeping pad.
b) Vibration pads (not included) may be used under components and pipe stands for
vibration isolation.
NOTE: Vibration pads, if used, should be placed under all components to ensure
proper alignment.
c) Floor load rating must be sufficient to accept filter weight. (Ref: Drawing CW)
d) Place system in close proximity to water to be filtered. Factory representative should
be consulted if filter will be over 20 feet from water source.
e) Protect system from water temperatures below 32 degrees F and above 140
degrees F unless filter is designed for those temperature applications.
Summary of Contents for CW130 Series
Page 1: ...Rev 6 07 High Efficiency Sand Filters CW130 Series ...
Page 21: ...18 6 07 2 4 Startup Data Sheet ...
Page 22: ...19 6 07 2 5 Filter Log Sheet ...
Page 31: ...28 6 07 ...
Page 36: ...33 CP Control Panel Enclosure with Labeled Components ...
Page 37: ...34 ...
Page 38: ......
Page 39: ...36 TBIO Input output strips on Terminal block labeled to indicate connection points ...
Page 40: ...37 CPIO Input output strips on PLC labeled to indicate connection points ...
Page 42: ......
Page 44: ...41 6 System Component Cut Sheets ...
Page 45: ...Model MCC INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS INSTRUCTION MANUAL IM060R04 ...