8
3.2.2 Installation Environment
Do not install the inverter in the place with poor ventilation.
Ensure that there has sufficient fresh-air supply around the inverter.
To ensure long service life and stable operation, avoid direct sunshine, rain or snow on the
inverter. It is recommended to install the inverter in the place where has cover, as shown in
Figure3-2.
Recommended installation direction: do not install the inverter under directly sunshine. The
countries in southern hemisphere (such as Australia, New Zealand) cannot install the inverter
towards north, the countries in northern hemisphere (such as the Netherlands, Spain) cannot
install the inverter towards south.
Figure3-2 Recommended installation site
The inverter must be installed on the wall or supporter with enough bearing capacity.
Consider the visibility of indicators and LCD.
3.2.3 Installation Space
Keep at least 500mm from the left and right side of the inverter to other objects or inverters,
keep at least 600mm from the top of the inverter to ceiling and keep at least 600mm from
bottom of the inverter to ground, which is good for heat dissipation or maintenance, as shown
in Figure3-3.
Figure3-3 Installation space (unit: mm)