11
MODEL (A)BCG365T2508_, (A)BCG3100T2508_
Input: 250,000, 251,000
Total Vent Height (Feet)
Draft Hood: 6”
6
8
10
15
20
30
50
100
Input Btuh
Rise
Vent Connector Diameter (in inches)
250/251,000
1 Ft.
-
-
-
-
-
-
8
8
250/251,000
-
-
-
8
8
8
8
8
250/251,000
3 Ft.
-
8
8
8
-
8
7
7
Number
Combined Input
of Heaters
in Thousands of Btuh
Manifold and Common Vent Diameter (In inches)
2
480
14
12
12
10
10
10
8
8
500/502
14
12
12
10
10
10
10
8
3
720
14
14
14
12
12
12
10
10
750/753
16
14
14
14
12
12
10
10
4
960/1000/1004
18
16
16
14
14
14
12
12
MODEL (A)BCG3100T2758_
Input: 275,000 Btuh
Total Vent Height (Feet)
Draft Hood: 6”
6
8
10
15
20
30
50
100
Input Btuh
Rise
Vent Connector Diameter (in inches)
275,000
2 Ft.
-
-
-
-
-
8
8
8
275,000
3 Ft.
-
-
-
8
8
8
8
8
Numbers
Combined Input
of Heaters
in Thousands of Btuh
Manifold and Common Vent Diameter (in inches)
2
550
-
-
-
12
10
10
10
10
3
825
-
-
-
14
14
12
12
12
4
1100
-
-
-
16
14
14
12
12
MODEL (A)BCG365T3008_
Input: 305,000 Btuh
T otal Vent Height (Feet)
Draft Hood: 8”
6
8
10
15
20
30
50
100
Input Btuh
Rise
Vent Connector Diameter (in inches)
315,000
1 Ft.
-
-
10
10
10
10
10
10
305,000
2 Ft.
10
10
10
10
10
10
8
8
365,000
3 Ft.
10
10
10
10
10
8
8
8
Number of
Combined Input
Heaters
in Thousands of Btuh
Manifold & Common Vent Diameter
2
610
14
14
12
12
12
10
10
10
3
915
16
16
16
14
14
12
12
12
4
1220
18
18
16
16
16
14
14
12
MODEL (A)BCG385T3608_, (A)BCG3100T3908_
Input: 365,000, 399,000
Total Vent Height (Feet)
Draft Hood: 8”
6
8
10
15
20
30
50
100
Input Btuh
Rise
Vent Connector Diameter (in inches)
365,000
1 Ft.
-
-
-
-
-
10
10
10
400,000
-
-
-
-
-
-
10
10
365,000
2 FT.
12
12
10
10
10
10
10
10
400,000
12
12
12
12
10
10
10
10
365,000
3 FT.
10
10
10
10
10
10
10
10
400,000
12
10
10
10
10
10
10
10
Number of
Combined Input
Heaters
in Thousands of Btuh
Manifold & Common Vent Diameter (inches)
2
730
14
14
14
12
12
12
10
10
800
16
14
14
14
12
12
10
10
3
1095
18
18
16
16
14
14
12
12
1200
18
18
18
16
16
14
14
12
4
1460
20
20
18
18
16
16
14
12
1600
22
20
20
18
18
16
14
14
TECHNICAL DATA VENTING, TABLE 3 (Continued)