C

    

REPLACE BATTERY; Fig. 11, 11a

1.   Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in 

back of FLUSH VALVE COVER 

(3)Fig. 11

2.   Rotate COVER (3) to the right and pull off. Fig. 11
3.   Turn COVER (3) over and disconnect the SENSOR (4)  

from the BATTERY HOLDER 

(5). Remove the BATTERY 

CONTAINER 

(6) with BATTERY HOLDER (5) and  

BATTERY 

(7) inside. Fig. 11a.

4.   Remove BATTERY HOLDER (5) from BATTERY  

CONTAINER 

(6)Fig. 11a.

5.   Remove old BATTERY from BATTERY HOLDER (5).  

Install the new BATTERY 

(7) making sure the shape  

of the BATTERY follows the shape of the BATTERY  

HOLDER 

(5)Fig. 11a.

6.   Insert BATTERY HOLDER (5) with BATTERY into  

BATTERY CONTAINER 

(6). Insert BATTERY  

CONTAINER 

(6) into flush valve COVER (3)Fig. 11a.

7.   Connect BATTERY HOLDER (5) to SENSOR (4) and  

reverse the above steps to assemble flush valve. 

Fig. 11a.  

3

3

4

8

3

1

Fig. 11

Fig. 11a

Fig. 11b

REMOVE OLD

BATTERY

REMOVE

BATTERY

HOLDER

INSTALL

NEW

BATTERY

2

5

4

5

CR-P2

CR-P2

5

7

6

6

REMOVE OLD

LONG LIFE

POWER PACK

LONG LIFE POWER PACK

STANDARD BATTERY

INSTALL NEW

LONG LIFE

POWER PACK

8

Summary of Contents for SELECTRONIC 6062.601

Page 1: ...278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0 125 0 25 0 5 1 0 GPF Installation Inst ru ct io n s Certified to co...

Page 2: ...TH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE 1 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 2 3 4...

Page 3: ...8 134 mm 4 1 4 TO 5 1 4 FOR 3 4 TOP SPUD FIXTURES MANUAL OVERRIDE BUTTON DETECTION ZONE 400 800 mm 15 3 4 TO 31 1 2 C L 152 mm MIN 6 MIN Note The Critical Line C L on Vacuum Breaker must typically be...

Page 4: ...s All piping behind the walls should be properly secured and fastened Water supply lines must be sized to provide an adequate volume of water for each fixture Flush all water lines prior to operation...

Page 5: ...from finished wall to first thread of Adapter or threaded supply pipe dimension X Cut COVER TUBE 1 to length X Apply Teflon Tape to the threaded end of the Adapter or supply pipe 2 Push WALL ESCUTCHEO...

Page 6: ...Lubricate the O RING 3 with water if necessary Lightly tighten COUPLING NUT 4 Fig 8 Important Do not use lubricants other than water or any type of thread sealing paste or tape 2 Align the FLUSH VALV...

Page 7: ...ly 3 seconds 4 Adjust STOP VALVE 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace STOP VALVE...

Page 8: ...move old BATTERY from BATTERY HOLDER 5 Install the new BATTERY 7 making sure the shape of the BATTERY follows the shape of the BATTERY HOLDER 5 Fig 11a 6 Insert BATTERY HOLDER 5 with BATTERY into BATT...

Page 9: ...he program code after power connection is made 5 While the SENSOR CONTROL LED 1 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the sensor Fig 14 6 When the LED 1 stops blinking and s...

Page 10: ...RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS PUSH MANUAL OVERRIDE BUTTON WILL THE UNIT FLUSH REPLACE PISTON ASSEMBLY CLOSE ANGLE STOP AND OPEN AGAIN TO PRIME THE VALVE DOES FLUSHING STOP...

Page 11: ...BLY M964802 0070A SOLENOID PISTON SUBASSEMBLY Standard Battery 6063 Series A917376 0070A SET SCREW A912809 0070A O RING M964075 0070A 3 4 SWEAT ADAPTER M962926 0070A 1 SWEAT ADAPTER M964347 0020A STOP...

Reviews: