American Standard SELECTRONIC 6062.601 Installation Instructions Manual Download Page 5

5

   M965647 REV. 1.6 (5/17)

CENTER LINE OF

FIXTURE SPUD

FINISHED WALL

FILE EDGES

SOLDER

ADAPTER

Fig. 3 

ADAPTER

32mm

(1-1/4")

A

(A-B)=

B

C

CLEAN

Fig. 4a

Fig. 4b

Fig. 4c

1

1

4

2

3

Fig. 4

TEFLON TAPE

FINISHED WALL

X

X

2

1

2

3

4

5

Fig. 5

3/4" TOP SPUD

FLUSH VALVE INSTALLATION

1

    

INSTALL SWEAT ADAPTER; Fig. 3

Note:  Install Optional Sweat Adapter (Supplied) for  

copper pipe supply line.
1.  Measure the distance (A) from the finished wall to the      

center of the inlet spud on the fixture.

2.  Cut the supply pipe 1-1/4" (A-B=C) shorter than the 

measurement taken in Step 1. File any rough edges  

off the end of the supply pipe.

3.  Clean the end of the supply pipe. Push the threaded      

Adapter until it is seated against the internal stop. 

Sweat the Adapter to the pipe.

2

    

 INSTALL COVER TUBE, WALL 

ESCUTCHEON and STOP VALVE;  

Fig. 4

1.  Measure from finished wall to first thread of Adapter or 

threaded supply pipe (dimension “X”). Cut COVER TUBE  

(1) to length (X). Apply Teflon Tape to the threaded end of 

the Adapter or supply pipe.  

2.  Push WALL ESCUTCHEON (2) onto the COVER TUBE (1).        

Slide both onto the SUPPLY PIPE 

(3).

3.  Push the COVER TUBE (1) in to expose the threads of      

the supply pipe. With a wrench thread the STOP VALVE  

(4) onto the SUPPLY PIPE (3). Align and tighten.

4.  Pull COVER TUBE (1) against STOP VALVE (4) and push 

WALL ESCUTCHEON 

(2) against finished wall. 

3

    

 INSTALL  VACUUM  BREAKER   

TUBE;  Fig. 5

1.  Place the SPUD FLANGE (1) over the spud on  

the Fixture.

2.  Place FRICTION WASHER (3) and SEAL WASHER 

(4) inside SPUD COUPLING NUT (2) and thread  

onto Spud. Do not tighten fully.

3.  Insert the VACUUM BREAKER TUBE (5) into the  

SPUD COUPLING NUT 

(2) and push it down.

Note: If cutting VACUUM BREAKER TUBE (5) to size, note 

that Critical Line (C/L) on Vacuum Breaker must typically 

be 6" (152mm) above fixture. Consult Code for details.

CAUTION

Turn water supplies off before 

beginning

Summary of Contents for SELECTRONIC 6062.601

Page 1: ...278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0 125 0 25 0 5 1 0 GPF Installation Inst ru ct io n s Certified to co...

Page 2: ...TH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE 1 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 2 3 4...

Page 3: ...8 134 mm 4 1 4 TO 5 1 4 FOR 3 4 TOP SPUD FIXTURES MANUAL OVERRIDE BUTTON DETECTION ZONE 400 800 mm 15 3 4 TO 31 1 2 C L 152 mm MIN 6 MIN Note The Critical Line C L on Vacuum Breaker must typically be...

Page 4: ...s All piping behind the walls should be properly secured and fastened Water supply lines must be sized to provide an adequate volume of water for each fixture Flush all water lines prior to operation...

Page 5: ...from finished wall to first thread of Adapter or threaded supply pipe dimension X Cut COVER TUBE 1 to length X Apply Teflon Tape to the threaded end of the Adapter or supply pipe 2 Push WALL ESCUTCHEO...

Page 6: ...Lubricate the O RING 3 with water if necessary Lightly tighten COUPLING NUT 4 Fig 8 Important Do not use lubricants other than water or any type of thread sealing paste or tape 2 Align the FLUSH VALV...

Page 7: ...ly 3 seconds 4 Adjust STOP VALVE 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace STOP VALVE...

Page 8: ...move old BATTERY from BATTERY HOLDER 5 Install the new BATTERY 7 making sure the shape of the BATTERY follows the shape of the BATTERY HOLDER 5 Fig 11a 6 Insert BATTERY HOLDER 5 with BATTERY into BATT...

Page 9: ...he program code after power connection is made 5 While the SENSOR CONTROL LED 1 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the sensor Fig 14 6 When the LED 1 stops blinking and s...

Page 10: ...RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS PUSH MANUAL OVERRIDE BUTTON WILL THE UNIT FLUSH REPLACE PISTON ASSEMBLY CLOSE ANGLE STOP AND OPEN AGAIN TO PRIME THE VALVE DOES FLUSHING STOP...

Page 11: ...BLY M964802 0070A SOLENOID PISTON SUBASSEMBLY Standard Battery 6063 Series A917376 0070A SET SCREW A912809 0070A O RING M964075 0070A 3 4 SWEAT ADAPTER M962926 0070A 1 SWEAT ADAPTER M964347 0020A STOP...