Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your 
installation proceeds smoothly--please read these instructions carefully before you begin.

Remove the Flush Valve items from the carton. The illustration below shows all items after they have been 
removed from the carton. Some items may be packaged partially assembled to other items.     

UNPACKING

All American Standard Products Are Water Tested At Our Factory. 
Some Residual Water May Remain In The Valve During Shipping.

 

1. Installation Instructions
2. Flush Valve Body Assembly
3. Vacuum Breaker Tube
4. Spud Coupling Nut and Washers
5. Spud Flange

6. Wall Escutcheon 

7. Cover Tube
 

8. Sweat Adapter

 9. Stop Valve

CARE INSTRUCTIONS:

DO: CLEAN THE PRODUCT WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

1

DO NOT REMOVE PROTECTIVE FILM FROM SENSOR

EYE UNTIL INSTALLATION IS COMPLETE.

2

3

4

5

8

6

9

7

NOTE TO INSTALLER: Please give this manual to the customer after installation.

To learn more about American Standard Selectronic

®

 Products visit our website at: 

www.americanstandard-us.com

or e-mail us at: 

[email protected]

For Parts, Service, Warranty or other Assistance, 
please call (844) CRT-TEAM / (844) 278-8326  (In Canada: 1-800-387-0369)
                                                                  (In Toronto Area only: 1-905-306-1093)
)

SELECTRONIC

®

DC POWERED PROXIMITY EXPOSED 

URINAL FLUSH VALVE  

0.125, 0.25, 0.5 & 1.0 GPF

Ins

tall

a

ti

o

n Inst

ruction

s

© 2017 AS America, Inc.

CAUTION: Use only American Standard supplied  
transformers and cable sets. Using non-AS supplied  
cables, or cutting, splicing or modifying any components  
will void the warranty.

Exposed Flushometer
for 3/4
" Top Spud Urinals

MODEL NUMBERS

6063.013

6062.601

6063.025

6063.505

6063.051

6063.510

6063.101

6063.513

Summary of Contents for SELECTRONIC 6062.601

Page 1: ...278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0 125 0 25 0 5 1 0 GPF Installation Inst ru ct io n s Certified to co...

Page 2: ...TH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE 1 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 2 3 4...

Page 3: ...8 134 mm 4 1 4 TO 5 1 4 FOR 3 4 TOP SPUD FIXTURES MANUAL OVERRIDE BUTTON DETECTION ZONE 400 800 mm 15 3 4 TO 31 1 2 C L 152 mm MIN 6 MIN Note The Critical Line C L on Vacuum Breaker must typically be...

Page 4: ...s All piping behind the walls should be properly secured and fastened Water supply lines must be sized to provide an adequate volume of water for each fixture Flush all water lines prior to operation...

Page 5: ...from finished wall to first thread of Adapter or threaded supply pipe dimension X Cut COVER TUBE 1 to length X Apply Teflon Tape to the threaded end of the Adapter or supply pipe 2 Push WALL ESCUTCHEO...

Page 6: ...Lubricate the O RING 3 with water if necessary Lightly tighten COUPLING NUT 4 Fig 8 Important Do not use lubricants other than water or any type of thread sealing paste or tape 2 Align the FLUSH VALV...

Page 7: ...ly 3 seconds 4 Adjust STOP VALVE 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace STOP VALVE...

Page 8: ...move old BATTERY from BATTERY HOLDER 5 Install the new BATTERY 7 making sure the shape of the BATTERY follows the shape of the BATTERY HOLDER 5 Fig 11a 6 Insert BATTERY HOLDER 5 with BATTERY into BATT...

Page 9: ...he program code after power connection is made 5 While the SENSOR CONTROL LED 1 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the sensor Fig 14 6 When the LED 1 stops blinking and s...

Page 10: ...RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS PUSH MANUAL OVERRIDE BUTTON WILL THE UNIT FLUSH REPLACE PISTON ASSEMBLY CLOSE ANGLE STOP AND OPEN AGAIN TO PRIME THE VALVE DOES FLUSHING STOP...

Page 11: ...BLY M964802 0070A SOLENOID PISTON SUBASSEMBLY Standard Battery 6063 Series A917376 0070A SET SCREW A912809 0070A O RING M964075 0070A 3 4 SWEAT ADAPTER M962926 0070A 1 SWEAT ADAPTER M964347 0020A STOP...

Reviews: