American Standard SELECTRONIC 6062.601 Installation Instructions Manual Download Page 11

11

M950354-0020A

MANUAL VALVE

M952261-0020A

3/4" INLET PIPE ASSEMBLY

M964412-0020A

3/4" VACUUM

BREAKER ASSEMBLY

M964402-0070A

VACUUM BREAKER KIT

M955062-0020A

1-1/4" VACUUM

BREAKER ASSEMBLY

FOR (6062.601)

M955058-0020A

3/4" STOP VALVE KIT

A955056-0020A

1" STOP VALVE KIT

M950319-0070500A

SENSOR ASSEMBLY (0.5 gpf)

M950319-0070300A

SENSOR ASSEMBLY (0.25 gpf)

M950319-0071000A

SENSOR ASSEMBLY (1.0 gpf)

M962801-0070A

FLOW REGULATOR

(Before July 2015)

M923189-0070A

FLOW REGULATOR

(After July 2015)

M964945-0020A

ADJUSTABLE TAILPIECE

(4-1/4" to 5-1/4" Rough-in)

OPTIONAL ADJUSTABLE TAILPIECE

(Purchased Separately)

M962836-0020A (8-1/4" to 9-1/4" Rough-in)
M962835-0020A (7-1/4" to 8-1/4" Rough-in)
M962834-0020A (6-1/4" to 7-1/4" Rough-in)
M962833-0020A (5-1/4" to 6-1/4" Rough-in)

A955057-0020A

1" INLET PIPE ASSEMBLY

FOR (6062.601)

M950319-0070130A

SENSOR ASSEMBLY (0.125 gpf)

M950514-0070A

BATTERY HOLDER

A923654-0070A

BATTERY 6V CR-P2

CR-P2

Standard Battery

6063. Series

Power Source

M906684-0070A

BONNET NUT

M964942-0020500A

COVER ASSEMBLY (0.5 gpf) 

M964942-0020250A

COVER ASSEMBLY (0.25 gpf) 

M964942-0021000A

COVER ASSEMBLY (1.0 gpf)

M964942-0020130A

COVER ASSEMBLY (0.125 gpf)

M964801-0070A

PISTON ASSEMBLY

M964302-0070A

SOLENOID ASSEMBLY

M964802-0070A

SOLENOID & PISTON

SUBASSEMBLY

Standard Battery  (6063. Series)

A917376-0070A

SET SCREW

A912809-0070A

O-RING

M964075-0070A

3/4" SWEAT ADAPTER

M962926-0070A

1" SWEAT ADAPTER

M964347-0020A

STOP VALVE CAP

M952262-0020A

3/4" SPUD ASSEMBLY

M952208-0020A

1-1/4" SPUD ASSEMBLY

FOR (6062.601)

M906684-0070A

BONNET NUT

M970343-0020500A

COVER ASSEMBLY (0.5 gpf) 

M970343-0020250A

COVER ASSEMBLY (0.25 gpf) 

M970343-0021000A

COVER ASSEMBLY (1.0 gpf)

M970343-0020130A

COVER ASSEMBLY (0.125 gpf)

M964801-0070A

PISTON ASSEMBLY

M964302-0070A

SOLENOID ASSEMBLY

M964802-0070A

SOLENOID & PISTON

SUBASSEMBLY

Standard Battery  (6063. Series)

A917376-0070A

SET SCREW

BEFORE NOVEMBER 2017

AFTER NOVEMBER 2017

SELECTRONIC

®

DC POWERED PROXIMITY EXPOSED  

URINAL FLUSH VALVE

0.125, 0.25, 0.5 & 1.0 GPF

   M965647 REV. 1.6 (5/17)

HOT LINE FOR  HELP

For toll-free information and answers to your questions, call:

(844) CRT-TEAM / (844) 278-8326

IN CANADA  1-800-387-0369   (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

IN MEXICO  01-800-839-1200

Product names listed herein are trademarks of AS America, Inc. ©2017

To learn more about American Standard Selectronic® Products visit our website at:

www.americanstandard-us.com or e-mail us at: [email protected]

Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST  Saturday 10:00 a.m. to 4:00 p.m. EST

BEFORE NOVEMBER 2017

MODEL NUMBERS

6063.013 6062.601

6063.025 6063.505
6063.051 6063.510

6063.101 6063.513

Summary of Contents for SELECTRONIC 6062.601

Page 1: ...278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 SELECTRONIC DC POWERED PROXIMITY EXPOSED URINAL FLUSH VALVE 0 125 0 25 0 5 1 0 GPF Installation Inst ru ct io n s Certified to co...

Page 2: ...TH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE 1 DO NOT REMOVE PROTECTIVE FILM FROM SENSOR EYE UNTIL INSTALLATION IS COMPLETE 2 3 4...

Page 3: ...8 134 mm 4 1 4 TO 5 1 4 FOR 3 4 TOP SPUD FIXTURES MANUAL OVERRIDE BUTTON DETECTION ZONE 400 800 mm 15 3 4 TO 31 1 2 C L 152 mm MIN 6 MIN Note The Critical Line C L on Vacuum Breaker must typically be...

Page 4: ...s All piping behind the walls should be properly secured and fastened Water supply lines must be sized to provide an adequate volume of water for each fixture Flush all water lines prior to operation...

Page 5: ...from finished wall to first thread of Adapter or threaded supply pipe dimension X Cut COVER TUBE 1 to length X Apply Teflon Tape to the threaded end of the Adapter or supply pipe 2 Push WALL ESCUTCHEO...

Page 6: ...Lubricate the O RING 3 with water if necessary Lightly tighten COUPLING NUT 4 Fig 8 Important Do not use lubricants other than water or any type of thread sealing paste or tape 2 Align the FLUSH VALV...

Page 7: ...ly 3 seconds 4 Adjust STOP VALVE 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 5 When adjustment is complete replace STOP VALVE...

Page 8: ...move old BATTERY from BATTERY HOLDER 5 Install the new BATTERY 7 making sure the shape of the BATTERY follows the shape of the BATTERY HOLDER 5 Fig 11a 6 Insert BATTERY HOLDER 5 with BATTERY into BATT...

Page 9: ...he program code after power connection is made 5 While the SENSOR CONTROL LED 1 is blinking slowly place your hand 1 to 2 in 30 50mm in front of the sensor Fig 14 6 When the LED 1 stops blinking and s...

Page 10: ...RECONNECT BATTERY TO SENSOR FLASH ON SENSOR FOR 5 SECONDS PUSH MANUAL OVERRIDE BUTTON WILL THE UNIT FLUSH REPLACE PISTON ASSEMBLY CLOSE ANGLE STOP AND OPEN AGAIN TO PRIME THE VALVE DOES FLUSHING STOP...

Page 11: ...BLY M964802 0070A SOLENOID PISTON SUBASSEMBLY Standard Battery 6063 Series A917376 0070A SET SCREW A912809 0070A O RING M964075 0070A 3 4 SWEAT ADAPTER M962926 0070A 1 SWEAT ADAPTER M964347 0020A STOP...