background image

SERVICE

5

Clogged CARTRIDGE outlets or inlets may cause reduced flow.

To clean, first turn off water supply then:

7

If faucet drips, operate HANDLE several times from "off" to "on." Do not

apply excessive force.

Reverse procedure to reinstall SPOUT 

(9)

.

Remove INDEX BUTTON 

(1)

, loosen HANDLE SCREW 

(2)

 and remove HANDLE 

(3)

.

Unthread the ESCUTCHEON CAP 

(4)

. Unthread three MOUNTING SCREWS 

(5)

.

Lift CARTRIDGE 

(6)

 off MANIFOLD 

(7)

.

Replace ESCUTCHEON CAP 

(4)

, HANDLE 

(3)

, tighten HANDLE SCREW 

(1)

 and install INDEX BUTTON 

(2)

.

Clean MANIFOLD 

(7)

 and CARTRIDGE 

(6)

 ports.

Place CARTRIDGE 

(6)

 onto MANIFOLD 

(7)

 and tighten MOUNTING SCREWS 

(5)

 alternately.

 

CARE:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

M 9 6 5 4 7 3   R ev.  1. 1

REMOVE

INSTALL

Spout leakage

. If fitting leaks above or below spout RETAINING COVER 

(8)

 remove SPOUT 

(9)

 as follows

and check SPOUT O-RING. First turn off water supply.

Unthread spout RETAINING COVER 

(8)

.

Remove SPOUT 

(9)

 by pulling up gently while moving SPOUT 

(9)

 side to side.

Check SPOUT O-RING 

(10)

 for damage. Replace if necessary.

The DIVERTER 

(11)

 can be cleaned by unthreading from faucet body. Rinse the DIVERTER 

(9) 

clean and

thread DIVERTER 

(11)

 back into faucet body.

1

3

12

9

8

11

10

2

4

5

6

7

REMOVE

RETAING RING

CLIP RING

INSTALL

Reduced flow

. If the flow gradually reduces over a

number of months, the AERATOR 

(12)

 may have

collected debris.To clean, remove AERATOR 

(12)

and rinse with water and remove any debris. Turn

on faucet to wash any debris out of the faucet.

Thread AERATOR 

(12)

 back into spout.

Operate faucet.

Summary of Contents for Portsmouth 4285.051

Page 1: ...ECK ESCUTCHEON Assemble RUBBER WASHER 4 BRASS WASHER 5 and threaded LOCKNUT 6 onto SHANK 3 from underside of sink or mounting surface Hand tighten LOCKNUT 6 Use a screwdriver to tighten SCREWS 7 on LOCKNUT 6 Work your way around LOCKNUT 6 tightening the screws slightly each time until all are snug to ensure even pressure Make certain the SEAL 9 is properly seated in recess of spout base A Installa...

Page 2: ...tion and replace AERATOR 1 6 3 4 CONNECT HOSE SPRAY Feed SPRAY HOSE 5 through SPRAY HOLDER 1 and attach COUPLING NUT 6 of HOSE 5 to SPRAY HOSE CONNECTION 3 on valve body Tighten COUPLING NUT 6 firmly 2 SPRAY HOSE CONNECTION MAKE WATER SUPPLY CONNECTIONS Turn off hot and cold water supplies before beginning Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3...

Page 3: ...EAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE M965473 Rev 1 1 REMOVE INSTALL Spout leakage If fitting leaks above or below spout RETAINING COVER 8 remove SPOUT 9 as follows and check SPOUT O RING First turn off water supply Unthread spout RETAINING COVER 8 Remove SPOUT 9 by pulling up gently while moving SPOUT 9 side to side Check SPOUT O RING 10 ...

Page 4: ...01 800 839 1200 P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c A S A m e r i c a I n c 2 0 1 3 HOT LINE FOR HELP 4285 051 PORTSMOUTH M953040 YYY0A SPRAY HOLDER M953668 YYY0A HANDSPRAY HOSE M964396 YYY0A HANDLE KIT M964397 0070A BUTTON AND SCREW KIT M907315 YYY0A ESCUTCHEON CAP M951483 0070A CARTRIDGE M964509 0070A RETAINER SEAL K...

Reviews: