background image

7 3 0 2 010 - 10 0   Rev. A

6

7

     INSTALL TOILET

a.  Position toilet squarely to wall and, with a rocking  
     motion, press bowl down fully on wax ring and flange.

Alternately tighten nuts until toilet is firmly seated on floor.

  

 CAUTION: 

DO NOT OVERTIGHTEN NUTS 

 

 

         OR BASE MAY BE DAMAGED!

b.  Install caps on washers. (If necessary, cut bolt height   
     to size before installing caps.)  

c.  Smooth off the bead of sealant around base. Remove  
     excess sealant.

INSTALL TOILET SEAT  

Install toilet seat in accordance with manufacturer's directions.

!

-   2   -

8a

8b

Before continuing, determine the type of water supply connecation you have from 
the chart below and use the appropriate assembly parts required to properly 
reconnect the water supply. DO NOT use plumber's putty to seal these fittings.

CAUTION: DO NOT USE 
CONE WASHER WITH 
PLASTIC SUPPLY LINE.

These parts must be used as 
illustrated to insure water-tight 
connection. Use of existing 
coupling nut may result in 
water leakage. Water supply 
tube or pipe must extend at 
least 1/2" inside threaded 
shank of valve (does not apply 
to flanged tubing).

Use existing 
coupling nut 
and washer.

Use existing spiral 
cone washer. 
Fluidmaster cone 
washer may not 
seal completely on 
spiral type supply 
line.

Captive cone 
washers already 
included. No 
additional washers 
needed.

CAUTION: Overtightening of 
LOCK NUT or COUPLING NUT 
could result in breakage and 
potential flooding.

METAL/COPPER

FLARED TUBING

METAL FLANGED

TUBING

METAL SPIRAL

TUBING

VINYL/BRAIDED

CONNECTOR

LOCK NUT

LOCK NUT

LOCK NUT

LOCK NUT

COUPLING
NUT

COUPLING
NUT

EXISTING
COUPLING
NUT

COUPLING
NUT

WATER
SHUT-OFF

WATER
SHUT-OFF

WATER
SHUT-OFF

WATER
SHUT-OFF

CONE
WASHER

EXISTING
CONE
WASHER

EXISTING
WASHER

With correct washers in place 
(see Step 8a), tighten COUPLING 
NUT 1/4 turn beyond hand tight. 
DO NOT OVERTIGHTEN.

BOLTS

CLOSET FLANGE

BOLT CAP

!

WARNING:

 Do not use plumber’s putty, pipe dope, or any other sealant on the water supply connection 

to this tank. If the connection leaks after hand tightening, replace the supply line. If the connection 
continues to leak with the new supply line, replace the fill valve. 

Warranty is void if any type of sealant is used on the water supply connection.

Summary of Contents for LOFT 2535

Page 1: ...d below 5 4 INSTALL WAX SEAL Invert toilet on floor cushion to prevent damage and install wax ring evenly around waste flange horn with tapered end of ring facing toilet Apply a thin bead of sealant a...

Page 2: ...t least 1 2 inside threaded shank of valve does not apply to flanged tubing Use existing coupling nut and washer Use existing spiral cone washer Fluidmaster cone washer may not seal completely on spir...

Page 3: ...VE MAY NOT TURN ON IF TOP IS NOT FULLY TURNED TO THE LOCKED POSITION For troubleshooting information please contact TROUBLESHOOTING IF FILL VALVE SHUTS OFF BUT CONTINUESTO LEAK SLOWLY repeat Step 12 I...

Page 4: ...low d Normal supply pressure must be at least 20 psi Toilet leaks a Poor supply line connection a Review Step 8 of installation procedure b Poor bowl to tank floor connection b Review Step 4 through 6...

Page 5: ...DE QUE USTED SE LASTIME NOTA Es posible que las ilustraciones no definan exactamente el contorno de la pieza y sus componentes 5 4 INSTALACI N DEL SELLO DE CERA Invierta el inodoro en el piso prot ja...

Page 6: ...ber as con brida Utilice la tuerca de acoplamiento y la arandela existentes Utilice la arandela c nica en espiral existente Es posible que la arandela c nica Fluidmaster no selle por completo en la l...

Page 7: ...lizar sello de reemplazo Fluidmaster Modelo 242 Visite nuestro sitio web en www fluidmaster com para consultar otras soluciones a los problemas de inodoro Para obtener informaci n sobre la soluci n de...

Page 8: ...un plomero si es necesario d La presi n del suministro est demasiado baja d La presi n del suministro normal debe ser de 20 psi por lo menos Fugas del inodoro a Mala conexi n de la l nea del suministr...

Page 9: ...S America Inc AS America Inc 2013 NOTE Les dessins peuvent ne pas correspondre exactement aux contours de l appareil ou des composantes 5 4 INSTALLER LE JOINT EN CIRE Renverser la toilette sur le plan...

Page 10: ...BLOQUANT CROU AUTO BLOQUANT CROU DE RACCORDEMENT CROU DE RACCORDEMENT CROU DE RACCORDEMENT D J EN PLACE CROU DE RACCORDEMENT ROBINET D ARR T D EAU ROBINET D ARR T D EAU ROBINET D ARR T D EAU ROBINET...

Page 11: ...ERVOIR D EAU SE FAIT TROP LENTEMENT apr s que la valve ait t en usage pendant un certain temps il faudrait songer opter pour le scellant de remplacement mod le 242 de Fluidmaster tout probl me de cuve...

Page 12: ...capuchon et nettoyer comme montr la fig 12 Chasse faible ou lente a Niveau d eau de la cuvette trop bas a V rifier si le tuyau de remplissage est raccord la commande d eau et ins r dans le trop plein...

Reviews: