background image

©2017 Ingersoll Rand

4A-V8-SF-1G-EN

SAFETY SECTION — OUTDOOR

IIm

mp

po

orrtta

an

ntt

— This document contains a wiring diagram

and service information. This is customer property and
is to remain with this unit. Please return to service
information pack upon completion of work.

W

WA

AR

RN

NIIN

NG

G

H

HA

AZ

ZA

AR

RD

DO

OU

US

S V

VO

OL

LT

TA

AG

GE

E!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w tth

hiiss W

Wa

arrn

niin

ng

g cco

ou

ulld

d rre

essu

ulltt iin

n

p

prro

op

pe

errtty

y d

da

am

ma

ag

ge

e,, sse

ev

ve

erre

e p

pe

errsso

on

na

all iin

njju

urry

y,, o

orr

d

de

ea

atth

h..

D

Diisscco

on

nn

ne

ecctt a

allll e

elle

eccttrriicc p

po

ow

we

err,, iin

nccllu

ud

diin

ng

g rre

em

mo

otte

e

d

diisscco

on

nn

ne

eccttss b

be

effo

orre

e sse

errv

viicciin

ng

g.. F

Fo

ollllo

ow

w p

prro

op

pe

err

llo

occkko

ou

utt//tta

ag

go

ou

utt p

prro

occe

ed

du

urre

ess tto

o e

en

nssu

urre

e tth

he

e p

po

ow

we

err

cca

an

nn

no

ott b

be

e iin

na

ad

dv

ve

errtte

en

nttlly

y e

en

ne

errg

giizze

ed

d..

W

WA

AR

RN

NIIN

NG

G

R

RE

EF

FR

RIIG

GE

ER

RA

AN

NT

T O

OIIL

L!!

A

An

ny

y a

atttte

em

mp

ptt tto

o rre

ep

pa

aiirr a

a cce

en

nttrra

all a

aiirr cco

on

nd

diittiio

on

niin

ng

g

p

prro

od

du

ucctt m

ma

ay

y rre

essu

ulltt iin

n p

prro

op

pe

errtty

y d

da

am

ma

ag

ge

e,, sse

ev

ve

erre

e

p

pe

errsso

on

na

all iin

njju

urry

y,, o

orr d

de

ea

atth

h..

T

Th

he

esse

e u

un

niittss u

usse

e R

R--4

41

10

0A

A rre

effrriig

ge

erra

an

ntt w

wh

hiicch

h o

op

pe

erra

atte

ess

a

att 5

50

0 tto

o 7

70

0%

% h

hiig

gh

he

err p

prre

essssu

urre

ess tth

ha

an

n R

R--2

22

2.. U

Usse

e o

on

nlly

y

R

R--4

41

10

0A

A a

ap

pp

prro

ov

ve

ed

d sse

errv

viicce

e e

eq

qu

uiip

pm

me

en

ntt.. R

Re

effrriig

ge

erra

an

ntt

ccy

ylliin

nd

de

errss a

arre

e p

pa

aiin

ntte

ed

d a

a “

“R

Ro

osse

e”

” cco

ollo

orr tto

o iin

nd

diicca

atte

e

tth

he

e tty

yp

pe

e o

off rre

effrriig

ge

erra

an

ntt a

an

nd

d m

ma

ay

y cco

on

ntta

aiin

n a

a “

“d

diip

p”

ttu

ub

be

e tto

o a

allllo

ow

w ffo

orr cch

ha

arrg

giin

ng

g o

off lliiq

qu

uiid

d rre

effrriig

ge

erra

an

ntt iin

ntto

o

tth

he

e ssy

ysstte

em

m.. A

Allll R

R--4

41

10

0A

A ssy

ysstte

em

mss w

wiitth

h v

va

arriia

ab

blle

e

ssp

pe

ee

ed

d cco

om

mp

prre

esssso

orrss u

usse

e a

a P

PV

VE

E o

oiill tth

ha

att rre

ea

ad

diilly

y

a

ab

bsso

orrb

bss m

mo

oiissttu

urre

e ffrro

om

m tth

he

e a

attm

mo

ossp

ph

he

erre

e.. T

To

o lliim

miitt

tth

hiiss “

“h

hy

yg

grro

osscco

op

piicc”

” a

accttiio

on

n,, tth

he

e ssy

ysstte

em

m ssh

ho

ou

ulld

d

rre

em

ma

aiin

n sse

ea

alle

ed

d w

wh

he

en

ne

ev

ve

err p

po

ossssiib

blle

e.. IIff a

a ssy

ysstte

em

m h

ha

ass

b

be

ee

en

n o

op

pe

en

n tto

o tth

he

e a

attm

mo

ossp

ph

he

erre

e ffo

orr m

mo

orre

e tth

ha

an

n 4

4

h

ho

ou

urrss,, tth

he

e cco

om

mp

prre

esssso

orr o

oiill m

mu

usstt b

be

e rre

ep

plla

acce

ed

d.. N

Ne

ev

ve

err

b

brre

ea

akk a

a v

va

accu

uu

um

m w

wiitth

h a

aiirr a

an

nd

d a

allw

wa

ay

yss cch

ha

an

ng

ge

e tth

he

e

d

drriie

errss w

wh

he

en

n o

op

pe

en

niin

ng

g tth

he

e ssy

ysstte

em

m ffo

orr cco

om

mp

po

on

ne

en

ntt

rre

ep

plla

acce

em

me

en

ntt..

C

CA

AU

UT

TIIO

ON

N

H

HO

OT

T S

SU

UR

RF

FA

AC

CE

E!!

M

Ma

ay

y cca

au

usse

e m

miin

no

orr tto

o sse

ev

ve

erre

e b

bu

urrn

niin

ng

g.. F

Fa

aiillu

urre

e tto

o

ffo

ollllo

ow

w tth

hiiss C

Ca

au

uttiio

on

n cco

ou

ulld

d rre

essu

ulltt iin

n p

prro

op

pe

errtty

y

d

da

am

ma

ag

ge

e o

orr p

pe

errsso

on

na

all iin

njju

urry

y..

D

Do

o n

no

ott tto

ou

ucch

h tto

op

p o

off cco

om

mp

prre

esssso

orr..

C

CA

AU

UT

TIIO

ON

N

C

CO

ON

NT

TA

AIIN

NS

S R

RE

EF

FR

RIIG

GE

ER

RA

AN

NT

T!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w p

prro

op

pe

err p

prro

occe

ed

du

urre

ess cca

an

n rre

essu

ulltt iin

n

p

pe

errsso

on

na

all iilllln

ne

essss o

orr iin

njju

urry

y o

orr sse

ev

ve

erre

e e

eq

qu

uiip

pm

me

en

ntt

d

da

am

ma

ag

ge

e..

S

Sy

ysstte

em

m cco

on

ntta

aiin

nss o

oiill a

an

nd

d rre

effrriig

ge

erra

an

ntt u

un

nd

de

err h

hiig

gh

h

p

prre

essssu

urre

e.. R

Re

ecco

ov

ve

err rre

effrriig

ge

erra

an

ntt tto

o rre

elliie

ev

ve

e p

prre

essssu

urre

e

b

be

effo

orre

e o

op

pe

en

niin

ng

g ssy

ysstte

em

m..

C

CA

AU

UT

TIIO

ON

N

G

GR

RO

OU

UN

ND

DIIN

NG

G R

RE

EQ

QU

UIIR

RE

ED

D!!

F

Fa

aiillu

urre

e tto

o iin

nssp

pe

ecctt o

orr u

usse

e p

prro

op

pe

err sse

errv

viicce

e tto

oo

ollss m

ma

ay

y

rre

essu

ulltt iin

n e

eq

qu

uiip

pm

me

en

ntt d

da

am

ma

ag

ge

e o

orr p

pe

errsso

on

na

all iin

njju

urry

y..

R

Re

ecco

on

nn

ne

ecctt a

allll g

grro

ou

un

nd

diin

ng

g d

de

ev

viicce

ess.. A

Allll p

pa

arrttss o

off tth

hiiss

p

prro

od

du

ucctt tth

ha

att a

arre

e cca

ap

pa

ab

blle

e o

off cco

on

nd

du

uccttiin

ng

g e

elle

eccttrriicca

all

ccu

urrrre

en

ntt a

arre

e g

grro

ou

un

nd

de

ed

d.. IIff g

grro

ou

un

nd

diin

ng

g w

wiirre

ess,, ssccrre

ew

wss,,

ssttrra

ap

pss,, cclliip

pss,, n

nu

uttss,, o

orr w

wa

assh

he

errss u

usse

ed

d tto

o cco

om

mp

plle

ette

e a

a

p

pa

atth

h tto

o g

grro

ou

un

nd

d a

arre

e rre

em

mo

ov

ve

ed

d ffo

orr sse

errv

viicce

e,, tth

he

ey

y m

mu

usstt

b

be

e rre

ettu

urrn

ne

ed

d tto

o tth

he

eiirr o

orriig

giin

na

all p

po

ossiittiio

on

n a

an

nd

d p

prro

op

pe

errlly

y

ffa

asstte

en

ne

ed

d..

W

WA

AR

RN

NIIN

NG

G

S

SE

ER

RV

VIIC

CE

E V

VA

AL

LV

VE

ES

S!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w tth

hiiss w

wa

arrn

niin

ng

g w

wiillll rre

essu

ulltt iin

n a

ab

brru

up

ptt

rre

elle

ea

asse

e o

off ssy

ysstte

em

m cch

ha

arrg

ge

e a

an

nd

d m

ma

ay

y rre

essu

ulltt iin

n

p

pe

errsso

on

na

all iin

njju

urry

y a

an

nd

d//o

orr p

prro

op

pe

errtty

y d

da

am

ma

ag

ge

e..

E

Ex

xttrre

em

me

e cca

au

uttiio

on

n ssh

ho

ou

ulld

d b

be

e e

ex

xe

errcciisse

ed

d w

wh

he

en

n

o

op

pe

en

niin

ng

g tth

he

e L

Liiq

qu

uiid

d L

Liin

ne

e S

Se

errv

viicce

e V

Va

allv

ve

e.. T

Tu

urrn

n v

va

allv

ve

e

sstte

em

m cco

ou

un

ntte

errccllo

occkkw

wiisse

e o

on

nlly

y u

un

nttiill tth

he

e sstte

em

m

cco

on

ntta

accttss tth

he

e rro

olllle

ed

d e

ed

dg

ge

e.. N

No

o tto

orrq

qu

ue

e iiss rre

eq

qu

uiirre

ed

d..

W

WA

AR

RN

NIIN

NG

G

B

BR

RA

AZ

ZIIN

NG

G R

RE

EQ

QU

UIIR

RE

ED

D!!

F

Fa

aiillu

urre

e tto

o iin

nssp

pe

ecctt lliin

ne

ess o

orr u

usse

e p

prro

op

pe

err sse

errv

viicce

e tto

oo

ollss

m

ma

ay

y rre

essu

ulltt iin

n e

eq

qu

uiip

pm

me

en

ntt d

da

am

ma

ag

ge

e o

orr p

pe

errsso

on

na

all

iin

njju

urry

y..

iiff u

ussiin

ng

g e

ex

xiissttiin

ng

g rre

effrriig

ge

erra

an

ntt lliin

ne

ess m

ma

akke

e cce

errtta

aiin

n tth

ha

att

a

allll jjo

oiin

nttss a

arre

e b

brra

azze

ed

d,, n

no

ott sso

olld

de

erre

ed

d..

W

WA

AR

RN

NIIN

NG

G

H

HIIG

GH

H L

LE

EA

AK

KA

AG

GE

E C

CU

UR

RR

RE

EN

NT

T!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w tth

hiiss W

Wa

arrn

niin

ng

g cco

ou

ulld

d rre

essu

ulltt iin

n

p

prro

op

pe

errtty

y d

da

am

ma

ag

ge

e,, sse

ev

ve

erre

e p

pe

errsso

on

na

all iin

njju

urry

y,, o

orr

d

de

ea

atth

h..

E

Ea

arrtth

h cco

on

nn

ne

eccttiio

on

n e

esssse

en

nttiia

all b

be

effo

orre

e cco

on

nn

ne

eccttiin

ng

g

e

elle

eccttrriicca

all ssu

up

pp

plly

y..

Summary of Contents for 4A6V8024A1000B

Page 1: ...injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment August 2017 4 4A A V V8 8 S SF F 1 1G G E EN N Var...

Page 2: ...Do o n no ot t t to ou uc ch h t to op p o of f c co om mp pr re es ss so or r C CA AU UT TI IO ON N C CO ON NT TA AI IN NS S R RE EF FR RI IG GE ER RA AN NT T F Fa ai il lu ur re e t to o f fo ol ll...

Page 3: ...with variable speed outdoor units Important Use caution when cleaning outdoor coil to ensure no water enters the electrical control compartment When cleaning coil from inside the compressor compartmen...

Page 4: ...4 4A V8 SF 1G EN Table 1 Operating Range Cooling 55 F to 120 F Table 1 Operating Range continued Heating 10 F to 66 F S SA AF FE ET TY Y S SE EC CT TI IO ON N O OU UT TD DO OO OR R...

Page 5: ...0 A R410 A LBS R 410A O D UNIT g 7 lb 6 oz 8 lb 3 oz 9 lb 8 oz FACTORY SUPPLIED YES YES YES LINE SIZE IN O D GAS h 5 8 3 4 3 4 LINE SIZE IN O D LIQ h 3 8 3 8 3 8 CHARGING SPECIFICATIONS SUBCOOLING 10...

Page 6: ...i LINE SIZE IN O D LIQ h 3 8 3 8 3 8 CHARGING SPECIFICATIONS SUBCOOLING 10 10 10 DIMENSIONS H X W X D H X W X D H X W X D CRATED IN 46 4 x 35 1 x 38 7 46 4 x 35 1 x 38 7 51 X 35 1 X 38 7 WEIGHT SHIPPI...

Page 7: ...lb 14 oz 9 lb 6 oz FACTORY SUPPLIED YES YES YES LINE SIZE IN O D GAS 5 8 h 3 4 h 3 4 h LINE SIZE IN O D LIQ h 3 8 3 8 3 8 CHARGING SPECIFICATIONS SUBCOOLING 10 10 10 DIMENSIONS H X W X D H X W X D H...

Page 8: ...RGING SPECIFICATIONS SUBCOOLING 10 10 DIMENSIONS H X W X D H X W X D CRATED IN 46 4 X 35 1 X 38 7 51 X 35 1 X 38 7 WEIGHT SHIPPING LBS 270 284 NET LBS 245 258 a Certified in accordance with the Air So...

Page 9: ...4 Locate the designated subcooling target from the unit nameplate 5 At startup or whenever charge is removed or added the system must be operated for a minimum of 20 minutes to stabilize before accur...

Page 10: ...00 110 120 130 140 150 60 50 40 30 20 50 40 30 25 15 10 0 REFRIGERANT LINE LIFT FEET Figure 4 Subcool Charging Corrections 5 0 Ton Add 2 Refrigerant Charging Chart R 410A REFRIGERANT CHARGING CHART LI...

Page 11: ...d record the resulting value This is the amount of refrigerant to weigh in prior to opening the service valves New Installation Weigh In Method Worksheet 1 Line Length ft ________________________ 2 Va...

Page 12: ...12 4A V8 SF 1G EN Wiring D157619P04...

Page 13: ...1G EN 13 Integrated Variable Speed Control IVSC Inputs Outputs A Al ls so o R Re ef fe er rr re ed d t to o a as s T Th he e D Dr ri iv ve e F AN ALUMINUM COVERPLATE T4 T3 10 1 18 9 J1 J4 D B J3 J10...

Page 14: ...ump Heat ON At power up when outdoor temperature is below 85 F When outdoor temperature is below 80 F and compressor dome temperature is less than the outdoor ambient temperature Sump Heat OFF When th...

Page 15: ...lue or stage demand the outdoor system will start and ramp to a target startup speed and hold steady for a minimum dwell period to ensure proper oil return This dwell period will typically last for 1...

Page 16: ...g defrost The Defrost Mode will be terminated after the OD coil temperature reaches 47 F or the maximum time override of 15 minutes has lapsed At Defrost termination the compressor will be commanded t...

Page 17: ...fr ro os st t I In ni it ti ia at ti io on n The calculated temperature difference between the outdoor temperature sensor and the coil temperature sensor is called Delta T Defrost can occur once the c...

Page 18: ...85 00 1071 0 80 190 87 78 982 0 74 195 90 56 901 0 70 200 93 33 828 0 65 205 96 11 762 0 61 210 98 89 702 0 57 215 101 67 647 0 53 TEMP F TEMP C THERMISTOR RESISTANCE OHMS VOLTS DC PIN TO PIN 220 104...

Page 19: ...0 0 38 105 40 56 5227 0 35 110 43 33 4695 0 31 115 46 11 4224 0 29 120 48 89 3808 0 26 125 51 67 3439 0 24 130 54 44 3111 0 21 135 57 22 2820 0 20 140 60 00 2559 0 18 Figure 7 Ambient Temperature Sens...

Page 20: ...r control has an NTC thermistor input for sensing the coil temperature This reading is used by the defrost algorithm on heat pump units The thermistor has a nominal resistance of 10k ohms at 75 F The...

Page 21: ...re Transducer Pins 7 White 8 Black 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 A working Suction Pressure Sensor is required for the following Start Up Pressure Limits Low Pressure Loss of Charge Pro...

Page 22: ...mpressor speed is limited to 2400 RPM Ramp up to demand speed and resume normal operation Dome Temperature Sensor is faulted in Heating mode Dome Sensor out of range Open Shorted Missing SUCT T SENSE...

Page 23: ...t has been exceeded and a 5 minute time out has been enforced Restart is allowed but with reduced capacity Overcharged Cooling Mode Outdoor Fan Failure clogged coil recirculation excessive high ambien...

Page 24: ...e occurs and allows control within the EEV range of operation EEV migrated to open position but superheat is not at the desired set point Valve is not responding to a change in position Possible stuck...

Page 25: ...r the technician should cycle power to the ODU If error 176 00 returns replace the Drive If replacement Drive has the same issue investigate for EMI and source 177 Drive Current Failure CUR DER 0 N A...

Page 26: ...ll clear the fault and retry every 5 minutes Resume normal operation DC bus voltage is less than 220VDC Low line voltage Verify supply voltage is between 187VAC and 253VAC This error can occur after a...

Page 27: ...erter temperature greater than the Derate threshold High Load condition heat sink performance loss check thermal grease cold plate torque INV T EX DER 4 Err 179 04 Compressor speed Derated This alert...

Page 28: ...connection or motor winding problem Verify wiring and windings Run Drive Diagnostics to confirm failure mode Reverse Rotation Protection Hard Lockout REV ROT LO 3 Err 181 03 Can t start system without...

Page 29: ...mode for warranty claim before replacing Drive ADC current range error ADC CUR EX 15 Wait Emergency shutdown Control will clear the fault and retry every 5 minutes Resume normal operation Control wil...

Page 30: ...o thermostat send Alert to CDA home screen menu and history Resume normal operation after compressor cutout time has elapsed CO 5 minutes Low Suction Pressure Protection in Heating Mode Less than 13 P...

Page 31: ...r speed to prevent higher load Compressor Dome Temperature Protection Limit compressor speed Low speed heating with high indoor ambient CMPR LUBE 5 N A Compressor Lubrication cycle Low speed operation...

Page 32: ...via Technician log in 950 history Drive output current is high High compressor speed with high Drive output current Limit compressor speed In heating mode high indoor coil load or high outdoor ambient...

Page 33: ...e for warranty claim before replacing Drive Hardware Variant Read Failure HW VAR RD F 3 Err 188 03 Shutdow Cycle Power to clear hard lockout condition Internal Error Cycle Power If error does not clea...

Page 34: ...1 Wait Shutdown and retry after 5 minutes Resume normal operation Control board temperature is high Shutdown and retry after 5 minutes High ambient conditions recirculation discharge air blocked coil...

Page 35: ...4A V8 SF 1G EN 35 Refrigeration Circuits for Heating and Cooling Figure 11 2 Ton HP 024 Models Figure 12 3 Ton HP 036 and 37 Models...

Page 36: ...4A V8 SF 1G EN Figure 13 4 Ton HP 048 Models Figure 14 4 Ton HP 049 Models R Re ef fr ri ig ge er ra at ti io on n C Ci ir rc cu ui it ts s f fo or r H He ea at ti in ng g a an nd d C Co oo ol li in n...

Page 37: ...8 SF 1G EN 37 Figure 15 5 Ton HP 060 Models Figure 16 2 TON A C 024 Models R Re ef fr ri ig ge er ra at ti io on n C Ci ir rc cu ui it ts s f fo or r H He ea at ti in ng g a an nd d C Co oo ol li in n...

Page 38: ...SF 1G EN Figure 17 3 Ton A C 036 and 037 Models Figure 18 4 Ton A C 048 Models R Re ef fr ri ig ge er ra at ti io on n C Ci ir rc cu ui it ts s f fo or r H He ea at ti in ng g a an nd d C Co oo ol li...

Page 39: ...4A V8 SF 1G EN 39 Figure 19 5 Ton A C 060 Models R Re ef fr ri ig ge er ra at ti io on n C Ci ir rc cu ui it ts s f fo or r H He ea at ti in ng g a an nd d C Co oo ol li in ng g...

Page 40: ...ompressor operation and closed contacts will enable compressor operation The Factory Default configuration is INACTIVE Upon enabling this feature the 950 850 will provide notification when this featur...

Page 41: ...4A V8 SF 1G EN 41 Communication Loss Yes Yes No Yes No No Yes No...

Page 42: ...42 4A V8 SF 1G EN Breaker Trip Procedure...

Page 43: ...4A V8 SF 1G EN 43 Start Compressor...

Page 44: ...44 4A V8 SF 1G EN Compressor Verification Parameters...

Page 45: ...4A V8 SF 1G EN 45 Run Drive Diagnostic Test e t...

Page 46: ...46 4A V8 SF 1G EN Compressor Verification Short...

Page 47: ...4A V8 SF 1G EN 47 Compressor Verification Open No Yes...

Page 48: ...48 4A V8 SF 1G EN Inverter Temperature e e...

Page 49: ...oling mode refrigerant flow is controlled by the expansion device in the indoor unit Therefore any ooperational problems observed in cooling mode are not caused by the outdoor EEV The following flow c...

Page 50: ...bout the CDA Home Screen Communicating Display Assembly Table 6 Status Menu Home Screen The System Status is shown continuously on the Home Screen The System Status will alternate with Fault Informati...

Page 51: ...he e M Mo on ni it to or r M Me en nu u d di is sp pl la ay ys s i in nf fo or rm ma at ti io on n o on n S Sy ys st te em m s st ta at tu us s D Dr ri iv ve e s st ta at ts s a an nd d t th he e S S...

Page 52: ...52 4A V8 SF 1G EN T Te ec ch hn ni ic ci ia an n M Mo on ni it to or r M Me en nu u...

Page 53: ...SF 1G EN 53 Technician Alert Menu The Alert Menu displays active alerts N No ot te e Clearing Alert History will also clear Active Alerts and will reset the Outdoor Control without the need to cycle...

Page 54: ...54 4A V8 SF 1G EN Technician Alert History Menu N No ot te e Clearing Alert History will also clear Active Alerts and will reset the Outdoor Control without the need to cycle power...

Page 55: ...chnician Configuration Menu S Sy ys st te em m p pa ar ra am me et te er rs s a an nd d o op pt ti io on ns s a ar re e r re ep po or rt te ed d a an nd d s se et t f fr ro om m t th he e C Co on nf f...

Page 56: ...chnician Control Menu Forced Defrost EEV LSOV Evacuation Run Drive and Run Outdoor Fan tests are initiated and performed from the Technician Control Menu N No ot te e If system is in Lockout Unit Test...

Page 57: ...4A V8 SF 1G EN 57 T Te ec ch hn ni ic ci ia an n C Co on nt tr ro ol l M Me en nu u...

Page 58: ...58 4A V8 SF 1G EN TECH CONTROL Charge Check Charge Modes...

Page 59: ...4A V8 SF 1G EN 59 Pressure Curves Figure 20 4A6V8024A...

Page 60: ...60 4A V8 SF 1G EN Figure 21 4A6V8036A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 61: ...4A V8 SF 1G EN 61 Figure 22 4A6V8037A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 62: ...62 4A V8 SF 1G EN Figure 23 4A6V8048A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 63: ...4A V8 SF 1G EN 63 Figure 24 4A6V8049A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 64: ...64 4A V8 SF 1G EN Figure 25 4A6V8060A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 65: ...4A V8 SF 1G EN 65 Figure 26 4A7V8024A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 66: ...66 4A V8 SF 1G EN Figure 27 4A7V8036A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 67: ...2 FIND INTERSECTION OF OD TEMP ID W B 3 READ LIQUID 4 OR SUCTION 5 PRESSURE IN LEFT COLUMN 1 OUTDOOR TEMP 82 F 2 INDOOR WET BULB 67 F 3 AT INTERSECTION 4 LIQUID PRESSURE 400 CFM IS 295 PSIG 5 SUCTION...

Page 68: ...68 4A V8 SF 1G EN Figure 29 4A7V8048A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 69: ...4A V8 SF 1G EN 69 Figure 30 4A7V8060A P Pr re es ss su ur re e C Cu ur rv ve es s...

Page 70: ...at Max 74 78 7 70 3 76 3 73 0 68 7 61 1 57 3 53 6 4A6V8048A Cool Min 61 70 6 55 0 55 9 55 8 59 0 49 9 41 1 42 9 Cool Max 74 75 7 71 9 73 0 74 2 68 5 63 4 59 1 54 3 Heat Min 62 72 1 59 3 58 7 60 3 58 6...

Page 71: ...00 Hz 4A7V8024A Cool Min 57 71 2 49 8 51 4 58 3 51 6 44 2 37 4 41 2 Cool Max 66 74 8 64 1 61 3 66 2 61 2 56 3 49 4 46 5 4A7V8036A Cool Min 55 71 0 53 4 51 2 53 5 51 5 44 6 40 3 41 0 Cool Max 70 73 1 7...

Page 72: ...codes found on the 950 comfort control Record all Alert texts found on the Communicating Display Assembly CDA Run the Drive Diagnostics found in the Technicians Control Menu of the CDA when possible W...

Page 73: ...4A V8 SF 1G EN 73 N No ot te es s...

Page 74: ...74 4A V8 SF 1G EN N No ot te es s...

Page 75: ...4A V8 SF 1G EN 75 N No ot te es s...

Page 76: ...d protect food and perishables and increase industrial productivity and efficiency We are a global business committed to a world of sustainable progress and enduring results ingersollrand com Ingersol...

Reviews: