background image

Owner’s Manual

        

Wood Chip Smoker

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

2

Appliances must be connected only to the type of gas identified 
on the rating plate.

WARNING

!

•  Before beginning, please read all the instructions carefully.

•  DO NOT remove permanently affixed labels, warnings, or plates from product.  This will void the warranty.

•  All local and national codes and ordinances must be observed; installation must conform with local codes.

•  The Installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.

•  Installation and service must be performed by a qualified installer, service agency or gas supplier.

•  Please ensure that the product is properly grounded.

IMPORTANT -  PLEASE READ AND FOLLOW!

SHIPPING DAMAGE CLAIM PROCEDURE
 
The equipment is crafted and inspected carefully by skilled personnel before leaving the factory.  The transportation company 
assumes full responsibility for the safe delivery upon acceptance of the equipment. 

If you receive a damaged product, immediately contact your delivery company, your dealer, your builder or installer.  Do not 
install or attempt to operate a damaged appliance.

1.  Note any visible loss or damage on the freight bill or express delivery and have the note signed by the person making 
     the delivery.
2.  File claim for damages immediately regardless of the extent of damages.
3.  For damage noticed after unpacking (concealed loss or damage), notify the transportation company immediately and file  
  a "Concealed Damage" claim with them.  This should be done within fifteen (15) days from the date that delivery  
  is made to you.  Retain the shipping container for inspection.

CALIFORNIA PROPOSITION 65 WARNING

The burning of gas cooking fuel generates some by-products which are on the list of substances known by the State of 

California to cause cancer or reproductive harm.  California law requires businesses to warn customers of potential exposure 

to such substances.  To minimize exposure to these substances, always operate this unit according to the Owners Manual, 

ensuring you provide proper ventilation when cooking with gas.

Your safety and the safety of others is very important.  We have provided many important safety messages in this manual and on 

your appliance.  Always read and obey all safety messages.

Summary of Contents for ARWCS-36

Page 1: ...91331 818 897 0808 tel 888 753 9898 toll free www americanrange com RETAIN THIS MANUAL FOR FUTURE REFERENCE DESIGN CLASS FUNCTION OWNER S MANUAL FOR WOOD CHIP SMOKER MODEL NUMBER ARWCS 36 Shown with...

Page 2: ...______________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date ________...

Page 3: ...you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for a quick solution or guidance regarding the next step required to get back to tip top condition T...

Page 4: ...10 Gas Utility Connections Standards Codes 4 Instructions 4 Ventilation Hood 5 Gas Standard Codes 5 Manual Shut offValve 6 Rating Plate 6 Gas Connection 7 Fuel Supply Pressure Link LeakTesting 7 Quic...

Page 5: ...tructions for local inspectors and for future use WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Page 6: ...product immediately contact your delivery company your dealer your builder or installer Do not install or attempt to operate a damaged appliance 1 Note any visible loss or damage on the freight bill o...

Page 7: ...ht the pilot and set frying temperatures The Care and Maintenance and Troubleshooting and Service Sections discuss how to keep your product in good operating condition how to identify what might be go...

Page 8: ...n Code CSA B149 1 as applicable including 1 The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pr...

Page 9: ...f this appliance must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Natural Gas Installation Code CAN CGA B149 1 or the Propane Installation Code...

Page 10: ...as pressure regulator must be installed in the gas line failure to install a pressure regulator will void the equipment warranty The regulators supplied with ranges have 3 4 NPT connections the regula...

Page 11: ...pped to operate on one certain fuel type The type of fuel with which the appliance is intended to operate is stamped on the data plate which is attached to the inside of the door FUEL SUPPLY AND PRESS...

Page 12: ...vel cakes casseroles and any other liquid or semi liquid batter will not bake evenly burner combustion may become erratic and the unit will not function properly If the kitchen floor is relatively smo...

Page 13: ...oven so chances of ignition are zero Knobs Heavy duty die cast knobs are provided so the operator can dial in the exact cooking temperatures needed for today s hot menu recipes Turning the knobs cloc...

Page 14: ...ent and accessible 0 Gas Supply line properly sized 0 Gas Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been develo...

Page 15: ...section for creating smoke from wood chips and directing it above the broiler burners but below the grates for best uptake by the meats poultry fish or vegetables you are cooking The Broiler Section o...

Page 16: ...Range Wood Chip Smoker Smoker Section is equipped with two wood chip trays and dedicated gas burners and control valves After the chips have been used up the tray can be pulled out of the unit using t...

Page 17: ...been operating long enough Unit preheats to 350 F quickly Too little gas pressure dirty gas line Call for authorized service SYMPTOM General broiler smoker problems Temperature surface too low or too...

Page 18: ...www americanrange com 14 1 2 3 4 8 9 10 7 6 5 12 13 14 16 17 15 18 19 20 21 22 23 11 Wood Chip Smoker ITEM NO PART NO DESCRIPTION 1 A32001 Knob 2 A32120 Handle 3 A17007 Grate 4 A17001 Grate 5 A17004 R...

Page 19: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 20: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...