INSTALLATION, OPERATION AND SERVICE PERSONNEL

Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel who are experienced 

in state/local installation codes.

Operation of the equipment should be performed by qualified or authorized personnel who have read this manual and understand 

and are familiar with the functions of the equipment.

Service of the equipment should be performed by qualified personnel who are knowledgeable with American Range products.

VENTILATION HOODS

A ventilation exhaust hood must be provided for any commercial, heavy-duty cooking appliance to exhaust combustion waste 

products to the outside of the building.  Usual practice is to place the unit under an exhaust hood.  Filters and drip troughs should be 

part of any industrial hood.  Consult local codes before constructing and installing a hood.

Room air movement should be monitored during installation.  Strong exhaust fans in the hood or in the overall air conditioning 

system can produce a slight vacuum in the room and/or cause air drafts – either may interfere with the pilot or main burner 

performance and can also be hard to diagnose.  If pilot burner or main burner outage problems persist – make up air openings or 

baffles may have to be provided in the room.

INSTALLATION - GAS STANDARDS AND CODES

IMPORTANT - 

The installation of this appliance must conform to local codes or, in the absence of local codes, with the National Fuel 

Gas Code ANSI Z223.1 Natural Gas Installation Code, CAN/CGA-B149-1 or the Propane Installation Code, CAN/CGA-B149-2 

as applicable, including:

1.  The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any 

  pressure testing of that system at test pressure in excess of 1/2 psi (3.45 kPa). 

2.  The appliance must be isolated from the gas supply piping system by closing the individual manual shut-off 

     valve during any pressure testing of the gas supply piping system.

The appliance, when installed, must be wired and electrically grounded in accordance with local codes, or in the absence of local 

codes, with the National Electric Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2 as applicable.

1.  A manual gas shut-off valve must be installed in the gas supply (service) line ahead of the appliance and gas pressure 
  regulator in the gas stream for safety and ease of future maintenance/service.
2.  The gas pressure regulator supplied with the appliance must be installed prior to connecting the equipment to the gas 
  supply line.  Failure to install a regulator will void the equipment warranty and result in a potentially hazardous condition.
3.  Please contact the factory, a factory representative, or local service company to perform maintenance and repairs.

DANGER

!

INSTALLATION

Owner’s Manual

      

Wood Chip Smoker

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

5

Summary of Contents for ARWCS-36

Page 1: ...91331 818 897 0808 tel 888 753 9898 toll free www americanrange com RETAIN THIS MANUAL FOR FUTURE REFERENCE DESIGN CLASS FUNCTION OWNER S MANUAL FOR WOOD CHIP SMOKER MODEL NUMBER ARWCS 36 Shown with...

Page 2: ...______________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date ________...

Page 3: ...you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for a quick solution or guidance regarding the next step required to get back to tip top condition T...

Page 4: ...10 Gas Utility Connections Standards Codes 4 Instructions 4 Ventilation Hood 5 Gas Standard Codes 5 Manual Shut offValve 6 Rating Plate 6 Gas Connection 7 Fuel Supply Pressure Link LeakTesting 7 Quic...

Page 5: ...tructions for local inspectors and for future use WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Page 6: ...product immediately contact your delivery company your dealer your builder or installer Do not install or attempt to operate a damaged appliance 1 Note any visible loss or damage on the freight bill o...

Page 7: ...ht the pilot and set frying temperatures The Care and Maintenance and Troubleshooting and Service Sections discuss how to keep your product in good operating condition how to identify what might be go...

Page 8: ...n Code CSA B149 1 as applicable including 1 The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pr...

Page 9: ...f this appliance must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Natural Gas Installation Code CAN CGA B149 1 or the Propane Installation Code...

Page 10: ...as pressure regulator must be installed in the gas line failure to install a pressure regulator will void the equipment warranty The regulators supplied with ranges have 3 4 NPT connections the regula...

Page 11: ...pped to operate on one certain fuel type The type of fuel with which the appliance is intended to operate is stamped on the data plate which is attached to the inside of the door FUEL SUPPLY AND PRESS...

Page 12: ...vel cakes casseroles and any other liquid or semi liquid batter will not bake evenly burner combustion may become erratic and the unit will not function properly If the kitchen floor is relatively smo...

Page 13: ...oven so chances of ignition are zero Knobs Heavy duty die cast knobs are provided so the operator can dial in the exact cooking temperatures needed for today s hot menu recipes Turning the knobs cloc...

Page 14: ...ent and accessible 0 Gas Supply line properly sized 0 Gas Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been develo...

Page 15: ...section for creating smoke from wood chips and directing it above the broiler burners but below the grates for best uptake by the meats poultry fish or vegetables you are cooking The Broiler Section o...

Page 16: ...Range Wood Chip Smoker Smoker Section is equipped with two wood chip trays and dedicated gas burners and control valves After the chips have been used up the tray can be pulled out of the unit using t...

Page 17: ...been operating long enough Unit preheats to 350 F quickly Too little gas pressure dirty gas line Call for authorized service SYMPTOM General broiler smoker problems Temperature surface too low or too...

Page 18: ...www americanrange com 14 1 2 3 4 8 9 10 7 6 5 12 13 14 16 17 15 18 19 20 21 22 23 11 Wood Chip Smoker ITEM NO PART NO DESCRIPTION 1 A32001 Knob 2 A32120 Handle 3 A17007 Grate 4 A17001 Grate 5 A17004 R...

Page 19: ...Notes 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com...

Page 20: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...