13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

8

WARNING

!

When water is at a high temperature and high pressure, excessive splashing of 
hot water may occur that could result in injury.

CASTER INSTALLATION

When installing provided casters, match holes on the caster with holes on the oven bottom base and fasten with the hardware 

provided.  Locking-type casters must be installed in the front.

Ovens with casters

 

must  be  installed  with  the  locking  front  casters  supplied,  a  flexible  connector  complying  with ANSI  Z21.69.

CGA6.16 and a quick-disconnect device complying with ANSI Z21.41CGA 6.9.  Adequate means must be provided to limit the 

movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit the 

appliance movement.

LEVELING 

A carpenter’s spirit level should be placed on the oven floor, and the unit leveled both front-to-back and side-to-side.  If the unit is not 

level, cakes, casseroles and any other liquid or semi-liquid batter will not bake evenly, burner combustion may become erratic, and the 

unit will not function properly.

If the kitchen floor is relatively smooth and level, the unit may be leveled by turning the "foot" section of the leg, since casters are not 

adjustable.  Identify the high corner and level the unit if the adjustment required exceeds the 1-1/4" limit use metal shims.

CHECK OPERATION

All American Range Corporation appliances are adjusted and tested before leaving the factory, effectively matching them to 

appropriate atmospheric conditions.  We recommend that adjustments and calibrations are performed upon installation to assure 

proper operation of the unit and avoid possible problems caused by rough handling or vibration during shipment.  This work must be 

performed only by qualified service personnel.  These adjustments are the responsibility of the customer and/or dealer and are not 

covered by warranty.

Check all gas connections for leaks with a soapy water solution before lighting the oven.  

DO NOT USE AN OPEN FLAME TO 

CHECK FOR LEAKS!  

Putting an open flame beside a new gas connection is extremely dangerous and may result in serious injury 

or death.

Summary of Contents for ARWCS-36

Page 1: ...91331 818 897 0808 tel 888 753 9898 toll free www americanrange com RETAIN THIS MANUAL FOR FUTURE REFERENCE DESIGN CLASS FUNCTION OWNER S MANUAL FOR WOOD CHIP SMOKER MODEL NUMBER ARWCS 36 Shown with...

Page 2: ...______________________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date ________...

Page 3: ...you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for a quick solution or guidance regarding the next step required to get back to tip top condition T...

Page 4: ...10 Gas Utility Connections Standards Codes 4 Instructions 4 Ventilation Hood 5 Gas Standard Codes 5 Manual Shut offValve 6 Rating Plate 6 Gas Connection 7 Fuel Supply Pressure Link LeakTesting 7 Quic...

Page 5: ...tructions for local inspectors and for future use WHATTO DO IFYOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Page 6: ...product immediately contact your delivery company your dealer your builder or installer Do not install or attempt to operate a damaged appliance 1 Note any visible loss or damage on the freight bill o...

Page 7: ...ht the pilot and set frying temperatures The Care and Maintenance and Troubleshooting and Service Sections discuss how to keep your product in good operating condition how to identify what might be go...

Page 8: ...n Code CSA B149 1 as applicable including 1 The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pr...

Page 9: ...f this appliance must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 Natural Gas Installation Code CAN CGA B149 1 or the Propane Installation Code...

Page 10: ...as pressure regulator must be installed in the gas line failure to install a pressure regulator will void the equipment warranty The regulators supplied with ranges have 3 4 NPT connections the regula...

Page 11: ...pped to operate on one certain fuel type The type of fuel with which the appliance is intended to operate is stamped on the data plate which is attached to the inside of the door FUEL SUPPLY AND PRESS...

Page 12: ...vel cakes casseroles and any other liquid or semi liquid batter will not bake evenly burner combustion may become erratic and the unit will not function properly If the kitchen floor is relatively smo...

Page 13: ...oven so chances of ignition are zero Knobs Heavy duty die cast knobs are provided so the operator can dial in the exact cooking temperatures needed for today s hot menu recipes Turning the knobs cloc...

Page 14: ...ent and accessible 0 Gas Supply line properly sized 0 Gas Supply pressure checked 0 Operating pressure checked 0 All connections checked for leaks INSTALLATION CHECKLIST This checklist has been develo...

Page 15: ...section for creating smoke from wood chips and directing it above the broiler burners but below the grates for best uptake by the meats poultry fish or vegetables you are cooking The Broiler Section o...

Page 16: ...Range Wood Chip Smoker Smoker Section is equipped with two wood chip trays and dedicated gas burners and control valves After the chips have been used up the tray can be pulled out of the unit using t...

Page 17: ...been operating long enough Unit preheats to 350 F quickly Too little gas pressure dirty gas line Call for authorized service SYMPTOM General broiler smoker problems Temperature surface too low or too...