background image

13592 Desmond St., Pacoima, CA 91331   818.897.0808 tel  888.753.9898 toll free   www.americanrange.com

1

Owner’s Manual

  ARRB,  AERB,  AECB,  ARKB,  ADJ,  AHS

Installation of the equipment should be performed by qualified, certified, licensed and/or authorized personnel who are familiar with 

the functions of the equipment and experienced with state/local installation codes.

Operation of the equipment should be performed by qualified or authorized personnel who have read this manual and are familiar 

with the functions of the equipment.
Service of the equipment should be performed by qualified personnel who are knowledgeable with American Range equipment.

The gas pressure regulator provided with the equipment must be installed when the appliance is connected to the gas supply. 
The area around the appliance must be kept free and clear of combustibles such as solvents, cleaning liquids, brooms, rags, etc. 
Proper clearances must be provided at the front of the appliances for servicing and proper operation.
Provisions shall be incorporated in the design of the kitchen, to ensure an adequate supply of fresh air and adequate clearance for 

air openings into the combustion chamber, for proper combustion and ventilation.  For proper operation of the appliance, do not 

obstruct the flow of combustion and ventilation air.
The installation must conform with local codes, or in the absence of local codes, with the national fuel gas code, ANSI Z223.1 - 1988 

(or latest addenda).
The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of 

that system in excess of 1/2 PSI.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure 

testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI.
The gas supply line must be at least 3/4" NPT.

SHIPPING DAMAGE CLAIM PROCEDURE
 
The equipment is crafted and inspected carefully by skilled personnel before leaving the factory.  The transportation company 
assumes full responsibility for the safe delivery upon acceptance of the equipment. 

If you receive a damaged product, immediately contact your delivery company, your dealer, your builder or installer.  Do not 
install or attempt to operate a damaged appliance.

1.  Note any visible loss or damage on the freight bill or express delivery and have the note signed by the person making 
     the delivery.
2.  File claim for damages immediately regardless of the extent of damages.
3.  For damage noticed after unpacking (concealed loss or damage), notify the transportation company immediately and file  
  a "Concealed Damage" claim with them.  This should be done within fifteen (15) days from the date that delivery  
  is made to you.  Retain the shipping container for inspection.

IMPORTANT

INSTALLATION INSTRUCTIONS

CALIFORNIA PROPOSITION 65 WARNING

The burning of gas cooking fuel generates some by-products which are on the list of substances known by the State of California to 

cause cancer or reproductive harm.  California law requires businesses to warn customers of potential exposure to such substances.  

To minimize exposure to these substances, always operate this unit according to the Owners Manual, ensuring you provide proper 

ventilation when cooking with gas.

Summary of Contents for ADJ

Page 1: ...3 9898 toll free www americanrange com OWNER S MANUAL FOR PROFESSIONAL SERIES COUNTERTOP BROILERS MODEL NUMBERS ARRB AERB AECB ARKB ADJ AHS PROFESSIONAL QUALITY COOKING EQUIPMENT DESIGN CLASS FUNCTION...

Page 2: ..._____________ Serial Number ___________________________________________ Purchase Date ___________________________________________ Installed By __________________________ Install Date __________ Gas Ty...

Page 3: ...you should encounter any sort of problem turn to the section of the manual entitled Troubleshooting for a quick solution or guidance regarding the next step required to get back to tip top condition T...

Page 4: ...Shipping Damage Claim Procedure 1 INSTALLATION 1 3 Instructions 1 Gas Standards and Codes 2 Gas Connection 2 Manual Shut OffValve 2 Rating Plate 3 Operating 3 4 Check for Gas Leaks 3 Open Burner Gridd...

Page 5: ...piping system during any pressure testing of that system in excess of 1 2 PSI The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during an...

Page 6: ...The blue air vent cap on the top of the regulator is part of the regulator and should not be removed Any adjustment to the regulator must be made only by qualified and licensed service personnel with...

Page 7: ...t adjustment screw clockwise to shut off gas to the pilots PILOT ADJUSTMENT SCREW MORE GAS LESS GAS RATING PLATE The information on the rating plate defines the model serial number gas type natural or...

Page 8: ...RKB ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 4 ARRB 1 O N O F F O N O F F O N O F F O N O F F O N O F F O N O F F 2 3 4 7 8 9 10 11 12 13...

Page 9: ...Plug 1 8 Pipe Hex Black All Manifolds 9 A29203 Pilot Tip Assembly ARRB ARRB ARKB 10242 10 A29301 Valve Dual Gas Pilot 1 8 x 3 16C 10432 11 A29004 Hood Orifice 50 1 2 Brass 11050 A29008 Hood Orifice 5...

Page 10: ...J AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 6 AERB 23 22 21 18 17 16 15 13 14 7 4 23 O N O F F O N O F F O N O F F O N O F F O N O F F O N O F...

Page 11: ...Quality Commercial Chrome 14 A44003 Nut Speed 6 Push Black 10601 15 A32001 Knob Gas On Off Glossy Black Flat Down 16 A80109 Valve Gas Manual On Off UL 10419 AR ARKB ARRB AECB 18 A29301 Valve Dual Gas...

Page 12: ...Owner s Manual ARRB AERB AECB ARKB ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 8 AECB 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 20 11...

Page 13: ...63 Manifold AECB 44 Char Broiler 2019 44 Counter Top 7 A44003 Nut Speed 6 Push Black 10601 8 A38000 Name Plate American Range 8 10499 Quality Commercial Chrome 10 A29301 Valve Dual Gas Pilot 1 8 x 3 1...

Page 14: ...CB ARKB ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 10 ARKB 1 O F F O N O F F O N O F F O N O F F O N O F F O N O F F O N 2 3 4 5 6 7 8 9 10...

Page 15: ...3 16C 10432 8 A44003 Nut Speed 6 Push Black 10601 10 A80154 Crumb Tray ARKB 24 1602 24 A80155 Crumb Tray ARKB 30 1602 30 A80156 Crumb Tray ARKB 36 1602 36 A80157 Crumb Tray ARKB 48 1602 48 11 A38000...

Page 16: ...B ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 12 ADJ 22 O N O F F O N O F F O N O F F O N O F F O N O F F O N O F F 23 20 19 21 11 10 9 3 2...

Page 17: ...Owner s Manual ARRB AERB AECB ARKB ADJ AHS 13592 Desmond St Pacoima CA 91331 818 897 0808 tel 888 753 9898 toll free www americanrange com 13 ADJ 24 25 26 27 28 26 29 30 31 32 33 34...

Page 18: ...AR ARKB ARRB AECB 14 A29004 Orifice Hood 50 1 2 Brass 11050 A29008 Orifice Hood 57 1 2 Brass 11057 A37154 Conversion Kit ADJ 48 LP Gas A37155 Conversion Kit ADJ 48 Nat Gas 15 A29301 Valve Dual Gas Pi...

Page 19: ...cal service company to perform maintenance and repairs For ARRB AERB ADJ AHS 1 DO NOT place any char rock charcoal or woodchips inside the unit 2 DO NOT use any acidic abrasive cleaners Such cleaners...

Page 20: ...certified licensed contractor Failure to comply will void any written or implied warranty Should the equipment require service during the standard warranty period the receipt proving certified instal...

Reviews: