   OWNER’S MANUAL

    INSTALLATION

Q U A L I T Y   P R O F E S S I O N A L   C O O K I N G   E Q U I P M E N T

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

NOTICE

!

NOTICE

!

NOTICE

!

NOTICE

!

NOTICE

!

NOTICE

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

The appliance is NOT jet stream approved. DO NOT clean the appliance with a 

water jet.

DO NOT use an open flame to check for gas leaks!

Installation must conform with local codes, or in the absence of local codes, with 

the National Fuel Gas Code. ANSI Z223.1, National Gas Installation Code. CAN/

CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2, CE Gas 

Appliance Directive’s 2009/142/EC (ex-90/396/EEC) Annex II, AU AS/NZS 5601, 

as applicable.

Post in a prominent location the instructions to be followed in the event that 

an operator smells gas. Obtain this information from your local gas supplier. 

Installation and servicing of the equipment should be performed by authorized 

personnel only and to AS/NZS 5601.

Completely shut the appliance down when shortening /oil is being drained from the 

appliance. This will prevent the appliance from heating up during the draining and 

filing process. Serious injury can occur.

The appliance is intended for indoor use only.

There is an open flame inside the appliance. The unit may get hot enough to set 

nearby materials on fire. Keep the area around the appliance free from combustibles.

• Hot oil and hot surfaces can cause sever burns. Use caution when operating the fryer.

• Do not attempt to move the fryer when filled with hot oil or shortening

• Drain hot oil into metal containers. Do not use plastic buckets or glass containers.

• Do not operate this unit without oil in vessel.

• Do not stand on fryer to clean overhead equipment.

• Do not go near the area directly above the flue when the fryer is in operation. Sever

burns may be caused.

When this appliance is installed with casters, it must be installed with the casters 

supplied, a connector complying with either ANSI Z21.69 CSA 6.16 and a quick-

disconnect device complying with ANSI Z21.41 CSA 6.9. It must also be installed with 

restraining means to guard against transmission of strain to the connector, as specified 

in the appliance manufacturer instructions. CE Gas Appliance Directive’s 2009/142/EC 

(ex-90/396/EEC) Annex II, AU AS/NZS 5601, as applicable.

These installations procedures must be followed by qualified personnel or warranty will 

be void. Local codes regarding installation vary greatly from one area to another. The 

National Fire Protection Association, Inc. States in its NFPA 96 latest edition that local 

codes are the “authority having jurisdiction” when it comes to installation requirements 

for equipment.

Ensure the appliance can get enough air to keep the flame burning correctly. If the 

flame is starved for air it can give off a dangerous carbon monoxide gas. Carbon 

Monoxide is a clear odorless gas that can cause suffocation.

Never add water to hot oil. Violent boiling can occur causing severe injury

Never add oil to the appliance when it is at operation temperature. Splashing hot 

oil can cause severe injuries.

This appliance is intended for professional use only and should be operated by 

fully trained and qualified personnel.

If disconnection of the restraint is necessary to move the appliance for cleaning 

etc., reconnect it when the appliance is moved to its original installed position

Units must be level to assure maximum performance. Improper leveling may void 

warranty.

All gas appliances vented through a ventilation hood or exhaust system with a 

damper or with a power means of exhaust shall comply AV AS/NZS 5601.

3

 

13592 Desmond St. Pacoima CA 91331 
Tel: 818.897.0808 

www.americanrange.com

 

Imported by Tom Stoddart Pty Ltd 

1300 79 1954 

www.stoddart.com.au

 

Summary of Contents for AAF-25W

Page 1: ...ained by consulting the local gas supplier All ULPG fryers must have a regulator installed between the gas tank H P and the fryer To be supplied by others If a the fryer is installed without the corre...

Page 2: ...13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au OWNER S MANUAL...

Page 3: ...an replacement parts are installed Be sure this Operator s Manual and important papers are given to the proper authority to retain for future reference DANGER WARNING CAUTION NOTICE Fire Hazard for yo...

Page 4: ...fryer is in operation Sever burns may be caused When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and...

Page 5: ...t cleaning If the unit is to be set on non combustible flooring such as a concrete slab 76 mm minimum toe room must be provided to prevent restriction of the air opening in the bottom of the unit WARN...

Page 6: ...will be needed Manometer DigitalThermometer Temperature Probe DC Millivolt Meter Installation and servicing of the equipment should be performed by authorized personnel only and to AS5600 STEP 4 GAS...

Page 7: ...shortening 9 Once the fry pot is filled with oil or shortening set the thermostat to the desired temperature 10 Close door 11 For complete shut down repeat steps 2 4 FILLING THE FRYPOT 1 Close drain...

Page 8: ...as high as 475 F or 246 C In the event the fryer shuts down due to this condition the oil must be cooled to below 400 F or 204 C before the pilot burner can be re ignited When the oil has cooled use t...

Page 9: ...th a clean cloth 5 Close drain valve and strain the oil back into the fry pot through several thicknesses of cheesecloth or filter it out using a filter machine 6 Replace the basket support frame if a...

Page 10: ...scouring in the direction of the polish lines using SCOTCH BRITE scouring pads or a STAINLESS scouring pad in combination with a powered cleanser Heat tint action may be lessened by not applying or by...

Page 11: ...s are carefully calibrated at the factory i e the dial is properly set to control appliance temperatures accurately Only a qualified appliance service technician should perform this adjustment 1 To ch...

Page 12: ...ded hooks to the mounted bracket on the wall Step 2 and the other to the eye bolt Steps 3 4 Cock Dial OFF PILOT ON Safety Magnet Pilot Outlet 1 4Tubing Pilot Adjuster Inlet Max Rated Pressure 14 W C 1...

Page 13: ...bination gas valve is in OFF position Pilot gas not adjusted properly Gas supply to unit off Bad thermopile Dirty thermopile connections at combination gas valve or high limit Clogged orifice Draft co...

Page 14: ...separate inlet and regulator which is incorporated with combination flame failure valves The unit is supplied with four adjustable legs x 150mm high or casters EXTERIOR PANELS 304 X 1 2 Stainless Stee...

Page 15: ...tween burner tubes x 125 from left hand of pan Floor Heat shield located on base of unit 670 x 380 1 2 aluminized steel Thermostat Capillary 750mm from top edge of pan Location Centered between burner...

Page 16: ...Y P R O F E S S I O N A L C O O K I N G E Q U I P M E N T AAF SERIES SPECIFICATIONS AAF 25W 40W 45W 15 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart...

Page 17: ...TLE 13592 DESMOND ST PACOIMA CA 91331 82154 01 10 2017 DATE 2342 REVISIONS ECN REV DESCRIPTION DATE APPROVED 2342 C INITIAL RELEASE 1 24 2019 MS 29 30 28 5 3 27 26 25 24 22 23 21 20 19 18 17 16 15 11...

Page 18: ...EMBLY 14 A23054 DRAIN PIPE EXTENSION 1 1 2 NPT 15 A13110 CIRCUIT INTERRUPTOR 16 A32048 KNOB TCTHERMOSTAT 17 82151 BRACKET T STAT HI LIMIT HOLDER CE 18 A10007 HI LIMITTHERMOSTAT 19 A50400 RXTHERMOSTAT...

Page 19: ...OWNER S MANUAL 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au...

Page 20: ...A70699 01292019 REV N 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au...

Reviews: