background image

   OWNER’S MANUAL

    SERVICE

Q U A L I T Y   P R O F E S S I O N A L   C O O K I N G   E Q U I P M E N T

CHECKING AND ADJUSTING AUTO SAFETY PILOT

The pilot flame should surround the thermopile for 1/2”. It must be larger and sharp  enough to cause the thermopile to glow a dull red, or sufficient to hold the safety 

valve open.

1.  Remove pilot adjustment cap.

2.  Adjust pilot to provide properly sized flame shown in diagram B. 

Diagram A shows an improperly adjusted pilot.

3.  Replace pilot adjustment cap.

1.  Restraining device should be installed parallel (in line) with the gas appliance

connector

2.  Attach the staple bracket to a stud in the wall, using the four 1” #10 screws and

the plastic anchors, if needed.

3.  Locate a structural area (frame) on  the rear side of the equipment that is

in line with the wall attachment. Drill a small hole 1/4” (per manufacturer’s

recommendation). Please use caution when drilling hole, so that internal

components are not damaged.

4.  Thread the hex nut and slide one washer onto the eye-bolt. Slide the eye-bolt

through the drilled hole and place a washer and the nylon lock nut onto the

eye-bolt on the inside frame of the equipment and tighten securely.

5.  Attach one of the spring loaded hooks to the mounted bracket on the wall

(Step 2) and the other to the eye bolt (Steps 3 & 4).

Cock Dial: OFF-PILOT-ON

Safety Magnet

Pilot Outlet: 1/4 Tubing

Pilot Adjuster

Inlet (Max Rated Pressure) 

14” W.C. (1/2 PSI)

Regulator

Terminal Seat

Operator

Upper Cap

Outlet

Outlet Pressure Test: 1/8” NPT

Side Outlet

Body

A

X

B

!

NOTICE

This procedure requires a DC millivolt meter set to scale of 0-1000mV. Using test leads with sharp probes will help in taking 

the required readings.

A53223 Rev. A

This Restraining Device Must Always Be 

Connected When The Appliance Is In Service

The restraining device should be disconnected for movement, 

such as, servicing or cleaning, 

ONLY AFTER GAS HAS 

BEEN SHUT OFF AND THE CONNECTOR HAS 

BEEN DISCONNECTED!

Reconnect restraining cable

 BEFORE 

reconnecting the gas 

connector and moving back to its original position.

NOTE: For adjustable restraining devices, the cable is manufactured to be shorter than the length of the gas connector. The length of the chain shall 

not exceed 80% of the length of the hose assembly. No warranty, representation or condition of any kind, express or implied (including any warranty 

of merchantability or of fitness) and none shall be implied by law. Shall not be liable for incidental or consequential damages. 

1

1

 

13592 Desmond St. Pacoima CA 91331 
Tel: 818.897.0808 

www.americanrange.com

 

Imported by Tom Stoddart Pty Ltd 

1300 79 1954 

www.stoddart.com.au

 

Summary of Contents for AAF-25W

Page 1: ...ained by consulting the local gas supplier All ULPG fryers must have a regulator installed between the gas tank H P and the fryer To be supplied by others If a the fryer is installed without the corre...

Page 2: ...13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au OWNER S MANUAL...

Page 3: ...an replacement parts are installed Be sure this Operator s Manual and important papers are given to the proper authority to retain for future reference DANGER WARNING CAUTION NOTICE Fire Hazard for yo...

Page 4: ...fryer is in operation Sever burns may be caused When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and...

Page 5: ...t cleaning If the unit is to be set on non combustible flooring such as a concrete slab 76 mm minimum toe room must be provided to prevent restriction of the air opening in the bottom of the unit WARN...

Page 6: ...will be needed Manometer DigitalThermometer Temperature Probe DC Millivolt Meter Installation and servicing of the equipment should be performed by authorized personnel only and to AS5600 STEP 4 GAS...

Page 7: ...shortening 9 Once the fry pot is filled with oil or shortening set the thermostat to the desired temperature 10 Close door 11 For complete shut down repeat steps 2 4 FILLING THE FRYPOT 1 Close drain...

Page 8: ...as high as 475 F or 246 C In the event the fryer shuts down due to this condition the oil must be cooled to below 400 F or 204 C before the pilot burner can be re ignited When the oil has cooled use t...

Page 9: ...th a clean cloth 5 Close drain valve and strain the oil back into the fry pot through several thicknesses of cheesecloth or filter it out using a filter machine 6 Replace the basket support frame if a...

Page 10: ...scouring in the direction of the polish lines using SCOTCH BRITE scouring pads or a STAINLESS scouring pad in combination with a powered cleanser Heat tint action may be lessened by not applying or by...

Page 11: ...s are carefully calibrated at the factory i e the dial is properly set to control appliance temperatures accurately Only a qualified appliance service technician should perform this adjustment 1 To ch...

Page 12: ...ded hooks to the mounted bracket on the wall Step 2 and the other to the eye bolt Steps 3 4 Cock Dial OFF PILOT ON Safety Magnet Pilot Outlet 1 4Tubing Pilot Adjuster Inlet Max Rated Pressure 14 W C 1...

Page 13: ...bination gas valve is in OFF position Pilot gas not adjusted properly Gas supply to unit off Bad thermopile Dirty thermopile connections at combination gas valve or high limit Clogged orifice Draft co...

Page 14: ...separate inlet and regulator which is incorporated with combination flame failure valves The unit is supplied with four adjustable legs x 150mm high or casters EXTERIOR PANELS 304 X 1 2 Stainless Stee...

Page 15: ...tween burner tubes x 125 from left hand of pan Floor Heat shield located on base of unit 670 x 380 1 2 aluminized steel Thermostat Capillary 750mm from top edge of pan Location Centered between burner...

Page 16: ...Y P R O F E S S I O N A L C O O K I N G E Q U I P M E N T AAF SERIES SPECIFICATIONS AAF 25W 40W 45W 15 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart...

Page 17: ...TLE 13592 DESMOND ST PACOIMA CA 91331 82154 01 10 2017 DATE 2342 REVISIONS ECN REV DESCRIPTION DATE APPROVED 2342 C INITIAL RELEASE 1 24 2019 MS 29 30 28 5 3 27 26 25 24 22 23 21 20 19 18 17 16 15 11...

Page 18: ...EMBLY 14 A23054 DRAIN PIPE EXTENSION 1 1 2 NPT 15 A13110 CIRCUIT INTERRUPTOR 16 A32048 KNOB TCTHERMOSTAT 17 82151 BRACKET T STAT HI LIMIT HOLDER CE 18 A10007 HI LIMITTHERMOSTAT 19 A50400 RXTHERMOSTAT...

Page 19: ...OWNER S MANUAL 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au...

Page 20: ...A70699 01292019 REV N 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au...

Reviews: