OWNER’S MANUAL
SERVICE
Q U A L I T Y P R O F E S S I O N A L C O O K I N G E Q U I P M E N T
CHECKING AND ADJUSTING AUTO SAFETY PILOT
The pilot flame should surround the thermopile for 1/2”. It must be larger and sharp enough to cause the thermopile to glow a dull red, or sufficient to hold the safety
valve open.
1. Remove pilot adjustment cap.
2. Adjust pilot to provide properly sized flame shown in diagram B.
Diagram A shows an improperly adjusted pilot.
3. Replace pilot adjustment cap.
1. Restraining device should be installed parallel (in line) with the gas appliance
connector
2. Attach the staple bracket to a stud in the wall, using the four 1” #10 screws and
the plastic anchors, if needed.
3. Locate a structural area (frame) on the rear side of the equipment that is
in line with the wall attachment. Drill a small hole 1/4” (per manufacturer’s
recommendation). Please use caution when drilling hole, so that internal
components are not damaged.
4. Thread the hex nut and slide one washer onto the eye-bolt. Slide the eye-bolt
through the drilled hole and place a washer and the nylon lock nut onto the
eye-bolt on the inside frame of the equipment and tighten securely.
5. Attach one of the spring loaded hooks to the mounted bracket on the wall
(Step 2) and the other to the eye bolt (Steps 3 & 4).
Cock Dial: OFF-PILOT-ON
Safety Magnet
Pilot Outlet: 1/4 Tubing
Pilot Adjuster
Inlet (Max Rated Pressure)
14” W.C. (1/2 PSI)
Regulator
Terminal Seat
Operator
Upper Cap
Outlet
Outlet Pressure Test: 1/8” NPT
Side Outlet
Body
A
X
B
!
NOTICE
This procedure requires a DC millivolt meter set to scale of 0-1000mV. Using test leads with sharp probes will help in taking
the required readings.
A53223 Rev. A
This Restraining Device Must Always Be
Connected When The Appliance Is In Service
The restraining device should be disconnected for movement,
such as, servicing or cleaning,
ONLY AFTER GAS HAS
BEEN SHUT OFF AND THE CONNECTOR HAS
BEEN DISCONNECTED!
Reconnect restraining cable
BEFORE
reconnecting the gas
connector and moving back to its original position.
NOTE: For adjustable restraining devices, the cable is manufactured to be shorter than the length of the gas connector. The length of the chain shall
not exceed 80% of the length of the hose assembly. No warranty, representation or condition of any kind, express or implied (including any warranty
of merchantability or of fitness) and none shall be implied by law. Shall not be liable for incidental or consequential damages.
1
1
13592 Desmond St. Pacoima CA 91331
Tel: 818.897.0808
www.americanrange.com
Imported by Tom Stoddart Pty Ltd
1300 79 1954