background image

   OWNER’S MANUAL

    SAFETY PRECAUTIONS

Q U A L I T Y   P R O F E S S I O N A L   C O O K I N G   E Q U I P M E N T

Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of precautions. Accidents and problems that can be 

caused by failure to follow fundamental rules and precautions.

The following symbols, found throughout this manual, alert you to potentially dangerous conditions to the operator, service personnel, or to the equipment.

!

This is the SAFETY ALERT SYMBOL. This symbol alerts you to hazards which will result in severe injury or death.

This symbol warn of immediate hazards or unsafe practices which will result in severe personal injury or death.

This symbol warn of immediate hazards or unsafe practices which will result in severe personal injury or death.

This symbol refers to potential hazards or unsafe practices which may result in minor personal injury or property damage.

American Range Fryers are intended for commercial use only. Not for household use. Warranty will be void if service 

work is performed by other than a qualified technician, or if other than genuine American replacement parts are installed. 

Be sure this Operator’s Manual and important papers are given to the proper authority to retain for future reference.

!

DANGER

!

WARNING

!

CAUTION

!

NOTICE

Fire Hazard for your safety. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or 

any other appliance. Keep area around appliances free and clear of combustibles. Purchaser of equipment must post in a 

prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from 

the local gas supplier.

Burn Hazard. Contact with hot oil will cause severe burns. Always use caution. Oil at 200°F is more dangerous than boiling 

water.

In the event a gas odor is detected, shut down equipment at the combination gas valve and contact the local gas company 

or gas supplier for service.

It is recommended that this appliance be inspected by a qualified service technician for proper performance and 

operation on a yearly basis.

This appliance is intended for professional use only and should be operated by fully trained and qualified personnel.

DO NOT spray aerosol while the unit is in operation.

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

13592 Desmond St. Pacoima CA 91331 
Tel: 818.897.0808 

www.americanrange.com

 

Imported by Tom Stoddart Pty Ltd 

1300 79 1954 

www.stoddart.com.au

 

Summary of Contents for AAF-25W

Page 1: ...ained by consulting the local gas supplier All ULPG fryers must have a regulator installed between the gas tank H P and the fryer To be supplied by others If a the fryer is installed without the corre...

Page 2: ...13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au OWNER S MANUAL...

Page 3: ...an replacement parts are installed Be sure this Operator s Manual and important papers are given to the proper authority to retain for future reference DANGER WARNING CAUTION NOTICE Fire Hazard for yo...

Page 4: ...fryer is in operation Sever burns may be caused When this appliance is installed with casters it must be installed with the casters supplied a connector complying with either ANSI Z21 69 CSA 6 16 and...

Page 5: ...t cleaning If the unit is to be set on non combustible flooring such as a concrete slab 76 mm minimum toe room must be provided to prevent restriction of the air opening in the bottom of the unit WARN...

Page 6: ...will be needed Manometer DigitalThermometer Temperature Probe DC Millivolt Meter Installation and servicing of the equipment should be performed by authorized personnel only and to AS5600 STEP 4 GAS...

Page 7: ...shortening 9 Once the fry pot is filled with oil or shortening set the thermostat to the desired temperature 10 Close door 11 For complete shut down repeat steps 2 4 FILLING THE FRYPOT 1 Close drain...

Page 8: ...as high as 475 F or 246 C In the event the fryer shuts down due to this condition the oil must be cooled to below 400 F or 204 C before the pilot burner can be re ignited When the oil has cooled use t...

Page 9: ...th a clean cloth 5 Close drain valve and strain the oil back into the fry pot through several thicknesses of cheesecloth or filter it out using a filter machine 6 Replace the basket support frame if a...

Page 10: ...scouring in the direction of the polish lines using SCOTCH BRITE scouring pads or a STAINLESS scouring pad in combination with a powered cleanser Heat tint action may be lessened by not applying or by...

Page 11: ...s are carefully calibrated at the factory i e the dial is properly set to control appliance temperatures accurately Only a qualified appliance service technician should perform this adjustment 1 To ch...

Page 12: ...ded hooks to the mounted bracket on the wall Step 2 and the other to the eye bolt Steps 3 4 Cock Dial OFF PILOT ON Safety Magnet Pilot Outlet 1 4Tubing Pilot Adjuster Inlet Max Rated Pressure 14 W C 1...

Page 13: ...bination gas valve is in OFF position Pilot gas not adjusted properly Gas supply to unit off Bad thermopile Dirty thermopile connections at combination gas valve or high limit Clogged orifice Draft co...

Page 14: ...separate inlet and regulator which is incorporated with combination flame failure valves The unit is supplied with four adjustable legs x 150mm high or casters EXTERIOR PANELS 304 X 1 2 Stainless Stee...

Page 15: ...tween burner tubes x 125 from left hand of pan Floor Heat shield located on base of unit 670 x 380 1 2 aluminized steel Thermostat Capillary 750mm from top edge of pan Location Centered between burner...

Page 16: ...Y P R O F E S S I O N A L C O O K I N G E Q U I P M E N T AAF SERIES SPECIFICATIONS AAF 25W 40W 45W 15 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart...

Page 17: ...TLE 13592 DESMOND ST PACOIMA CA 91331 82154 01 10 2017 DATE 2342 REVISIONS ECN REV DESCRIPTION DATE APPROVED 2342 C INITIAL RELEASE 1 24 2019 MS 29 30 28 5 3 27 26 25 24 22 23 21 20 19 18 17 16 15 11...

Page 18: ...EMBLY 14 A23054 DRAIN PIPE EXTENSION 1 1 2 NPT 15 A13110 CIRCUIT INTERRUPTOR 16 A32048 KNOB TCTHERMOSTAT 17 82151 BRACKET T STAT HI LIMIT HOLDER CE 18 A10007 HI LIMITTHERMOSTAT 19 A50400 RXTHERMOSTAT...

Page 19: ...OWNER S MANUAL 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au...

Page 20: ...A70699 01292019 REV N 13592 Desmond St Pacoima CA 91331 Tel 818 897 0808 www americanrange com Imported by Tom Stoddart Pty Ltd 1300 79 1954 www stoddart com au...

Reviews: