TROUBLESHOOTING GUIDE
PROBLEM
POSSIBLE CAUSE
WHAT TO DO
Burners do not come on
Gas supply to unit off. Combination gas valve is in
“OFF” or “PILOT” position. Pilot not ignited, or
adjusted. Thermostat not “ON”.
Pilot will not stay ignited
Combination gas valve is in “OFF” position. Pilot
gas not adjusted properly. Gas supply to unit off.
Bad thermopile. Dirty thermopile connections at
combination gas valve or high limit . Clogged orifice.
Draft condition. Air in gas line. Improper ventilation
system.
Pilot Produces carbon deposits
Unit connected to wrong gas supply. Pressure to
adjusted correctly. Pilot gas not adjusted correctly.