![background image](http://html1.mh-extra.com/html/american-fire-glass/ob-afpp-18eips-lp/ob-afpp-18eips-lp_installation-and-operating-instructions-manual_2924459013.webp)
12
Converting To A Different Gas Type (continued)
Figure 3
Disconnect propane hose and regulator (do not
discard)
Figure 5
Air shutter (Used only with natural
gas. Removed for propane gas.)
Figure 6
Re-connect 3/8” Natural Gas hose
and regulator (not included)
Orifice
(Remove to change to a different
gas type)
2.30mm-propane
3.78mm-natural gas
Burner Tube
Figure 4
Natural Gas Orifice and Natural Gas Air Shutter
(Included)