MEGAPOWER CPU
8200-0421-03, REV. G
ADMINISTRATOR’S GUIDE
62 of 82
2. Click
OK
to save your contact choices or
Cancel
to close the dialog box without saving your
choices.
Deleting Contacts
To delete contacts assigned to a monitor defined in
the Contact Arming tab, do the following:
1. In the upper screen, click on the monitor that
contains the contact(s) to be deleted.
2. Click on the contact(s) in the lower screen to be
deleted, and then click
Remove
on the right side
of the screen.
Event Timers
The Event Timers tab allows you to view or delete
event timer information that is associated with
selected monitors.
Note:
Event timers displayed in this screen are for
information only, and they cannot be added or edited
here, but they can be deleted. You must define event
timers in the Switching – Event Timer screen as
described on page 35.
Viewing Event Timers
To view event timer information from the Partitions –
Monitors to Cameras screen:
1. Click on a monitor in the upper screen.
2. Click the Event Timers tab in the lower screen.
Figure 136. Event timers screen
Deleting Event Timers
To delete an event timer definition:
1. Click on a monitor in the upper screen.
2. Click the header of the row in the lower screen
that contains the event timer definition to be
deleted.
3. Press the keyboard
Delete
key of the PC
running
EASY CPU. The Delete Rows dialog box
appears.
Figure 137. Delete Rows dialog
4. Click
Yes
to delete the event timer definition or
No
to close the dialog box without deleting the
definition.
Performing a Ping Test
A ping test checks and verifies the state of
communications between camera domes and the
MegaPower CPU. The ping test also reports
configuration information from the camera dome for
display on the EASY CPU camera status screen.
Refer to
Camera Status
on page 25 for detailed
information on the camera status screen.
To initiate a ping test, enter the special function key
29-F1
on your keyboard. Refer to
APPENDIX E:
Auxiliary Key Code Functions
on page 69 for a
listing of keyboard special function keys.
•
At the start of a ping test, the mnemonic and flash
version number data are displayed on a selected
monitor for a few seconds before the ping test
data is collected and displayed for the remainder
of the test.
•
As the test progresses, the monitor displays the
number of transmission attempts and the number
of failure counts (up to 6 digits) of the attempts
that failed to receive a reply from the dome.
A ping test allows concurrent testing of up to ten
domes to different monitors.
Summary of Contents for MegaPower ADMPCPU
Page 1: ...8200 0421 03 G MegaPower CPU ADMPCPU Administrator s Guide...
Page 2: ......
Page 85: ......