42
NOTE:
Once the Phase 5 OPL microprocessor controller (computer) detects a problem in the heat
circuit, it updates every 30-seconds. If the problem was a loose connection in this circuit
which corrected itself, the “dSFL” condition would automatically be cancelled.
3. “
SEFL
” - Indicates rotational sensor circuit failure meaning that there is a fault somewhere in the basket
(tumbler) rotation detection circuit, or the Phase 5 OPL microprocessor controller (computer) program
related to this circuit (Program Location 2) is set incorrectly in the active mode (
SEn
) where the dryer is
not equipped with the optional rotational sensor and
should be
set in the nonactive mode (
nSEn
).
4. “
Hot
” - Indicates a possible overheating condition. The Phase 5 OPL microprocessor controller (computer)
monitors the temperature in the dryer at
ALL
times. If the microprocessor controller (computer) detects
that the temperature in the dryer has exceeded 220º F (104º C), it will disable
ALL
outputs (shut the dryer
down), the tone (
bUZ
) will sound for approximately 5-seconds, and the light emitting diode (L.E.D.) display
will read “Hot” until the temperature has dropped to 220º F (104º C) or lower and the Phase 5 OPL
microprocessor controller (computer) is manually reset by pressing the “Clear/Stop” key.
B. L.E.D. DISPLAY INDICATORS
The L.E.D. indicator dots located at the top portion of the L.E.D. display (as shown in the
illustration below
)
indicate the Phase 5 OPL microprocessor controller (computer) output functions while a cycle is in progress.
These indicator dots
DO NOT
necessarily mean that the outputs are functioning. They are only indicating that
the function (output)
should be
active (on).
1. Blower Motor Circuit Indicator - Indicator dot is on whenever a cycle is in progress.
2. Heat Controller Indicator - Indicator dot is on whenever the Phase 5 OPL microprocessor controller
(computer) is calling for the heating circuit to be active (on).
3. Reversing Indicator - Indicator dot is on when the drive basket (tumbler) motor is operating in the reverse
mode (counterclockwise [CCW] direction).
4. Reversing Indicator - Indicator dot is on when the drive basket (tumbler) motor is operating in the forward
mode (clockwise [CW] direction).
Summary of Contents for AD-758