19
NOTES:
Before reestablishing power to the dryer, visually check the following (refer to the
illustration
):
1. The flame electrode, ignitor electrode, and ground rod are
ALL
on the same line axis.
2. There
should be
a 1/8” gap (+/- 1/32”) between the ignitor electrode and ground rod.
3.
DO NOT
wrap the red high voltage (HV) wire and the flame electrode wire together.
Improper operation may result. They may run alongside each other.
To Replace Gas Valve (refer to the burner
illustration
on
page 18
)
1. Discontinue electrical power to the dryer.
2. Close shutoff valve(s) in gas supply line.
3. Disconnect gas valve wiring.
NOTE:
Identify location of each wire for correct reinstallation.
4. Break union connection before gas valve.
5. Loosen and remove screws (4) securing pipe brackets to burner.
6. Remove gas valve/manifold assembly from dryer.
7. Remove valve mounting bracket, manifold, and piping from gas valve.
8. Reverse procedure for installing new gas valve.
WARNING:
Test
ALL
connections for leaks by brushing on a soapy water solution. NEVER TEST
FOR LEAKS WITH A FLAME.
To Replace Main Burner Orifices
1. Refer to “To Replace Gas Valve” and follow steps 1 through 6.
Summary of Contents for AD-758