12
American Dryer Corporation
113549 - 8
a. Reassembly Instructions For Non-Tilt Gas Dryers:
Lift the tumbler section onto the base.
1) The dryer has four (4) support posts assemblies, which are located in each corner of the base. On top of
each post assembly is a clevis block, which must be bolted to the tumbler section. Use the
4-1/2” diameter x 1-1/8” long bolts and lock washers to bolt each clevis block to the tumbler section.
(Refer to View 1 on the previous page.)
2) Tumbler power cable reconnection:
a) A plug and cable is located in the right of the base. This must be lifted up and reconnected into the
mating socket located at the bottom of the right tumbler section.
b) Pull the tumbler section power cable up from the left side of the base through the hole in the bottom of
the tumbler section. Reconnect the wires of this cable into the 2-inch x 4-inch (5.08 cm x 10.16 cm)
tumbler junction box located at the bottom of the tumbler section. (Refer to the illustration on the
previous page.)
c) Drop the control cable connector from the rear right side of the tumbler section into the base. Reconnect
the industrial grade plug in to its mating socket.
3) Bolt the 20-inch (50.8 cm) diameter exhaust duct transition piece to the dryers rectangular exhaust duct.
The exhaust duct exits the dryer from the rear of the base. (Refer to the illustration on the previous
page.) Use the 1/4-20 self-drilling screws supplied with the dryer.