40
American Dryer Corp.
113289 - 6
REVERSING TIMER SPIN / DWELL ADJUSTMENTS
Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left
rear area of the dryer.
Both the dwell (stop) time and the tumbler spin time are adjustable by mode selection switches located on the
electronic timer (as noted in the
illustration below
).
TIMING LEGEND
SPIN TIME
Adjustment Position Number
1
2
3
4
5
Time in Seconds*
30
60
90
120
150
DWELL (STOP) TIME
Adjustment Position Number
1
2
3
4
5
Time in Seconds*
5
6.3
7.6
8.9
10.2
* Values shown are +/- 1-second.
L. COMPRESSED AIR REQUIREMENTS
This model dryer requires an external supply of compressed air (3.5 cfh at 80 psi [0.09 cmh at 5.51 bar] for gas
models and 4.25 cfh at 80 psi [0.12 cmh at 5.51 bar] for steam models). For steam models, compressed air is
necessary for the air (standard) operated steam damper. (No damper is provided with [optional] steam solenoid
valve.) On both the steam models as well as the gas models, compressed air is necessary/required for blower air
jet operation to clean lint from the impellor/fan (squirrel cage).
1. Air Requirements
a. Microprocessor Controller (Computer) Dryers
Shaded areas are stated in metric equivalents
2. Air Regulation
No air regulation or air filtration is provided with the dryer. External regulation/filtration of 80 psi (5.51 bar)
must be
provided. It is suggested that a filter/regulator/gauge arrangement be added to the compressed
air line just before the dryer connection. This is necessary to ensure that correct and clean air pressure is
achieved.
Compressed
Air Supply
Air Pressure
Normal
80 psi
5.51 bar
Minimum Supply
70 psi
4.82 bar
Maximum Supply
90 psi
6.21 bar
Summary of Contents for AD-202
Page 10: ...6 American Dryer Corp 113289 6 202 SPECIFICATIONS WITH MANUAL VERTICAL DOOR ...
Page 11: ...113289 6 www adclaundry com 7 202 SPECIFICATIONS STEAM WITH OPTIONAL STEEL STEAM COIL ...
Page 13: ...113289 6 www adclaundry com 9 202DR SPECIFICATIONS WITH MANUAL VERTICAL DOOR ...
Page 15: ...113289 6 www adclaundry com 11 202 AGA SPECIFICATIONS WITH MANUAL VERTICAL DOOR ...
Page 35: ...113289 6 www adclaundry com 31 ...
Page 62: ...ADC Part No 113289 6 02 07 15 ...