Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

X-Move LED Plus R.The American DJ

®

 X-Move LED

 

Plus R is available 

in a 120v and 220v version. Because line voltage may vary from venue 
to venue, you should be sure your unit voltage matches the wall outlet 
voltage before attempting to operate you fixture.  Also be sure to only 
use the included I.E.C. power cable supplied with the unit, this cable 
matches the voltage and current requirements of the unit.

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used by most lighting and controller manufactures as a form of 
communication  between  intelligent  fixtures  and  controllers. 

A  DMX 

controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture 
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX 
fixtures (most controllers only have a DATA “OUT” terminal). 

DMX  Linking: 

DMX  is  a  language  allowing  all  makes  and  models 

of  different  manufactures  to  be  linked  together  and  operate  from  a 
single  controller,  as  long  as  all  fixtures  and  the  controller  are  DMX 
compliant.

  To  ensure  proper  DMX  data  transmission,  when  using 

several DMX fixtures try to use the shortest cable path possible. The 
order in which fixtures are connected in a DMX line does not influence 
the DMX addressing. For example; a fixture assigned a DMX address 
of 1 may be placed anywhere in a DMX line, at the beginning, at the 
end, or anywhere in the middle. Therefore, the first fixture controlled 
by the controller could be the last fixture in the chain. When a fixture 
is  assigned  a  DMX  address  of  1,  the  DMX  controller  knows  to  send 
DATA assigned to address 1 to that unit, no matter where it is located 
in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX 

and  Master/Slave  Operation): 

The  X-Move  LED 

Plus  R  can  be  controlled  via  DMX-512  protocol. 
The  X-Move  LED  Plus  R  is  a  nine  channel  DMX 
unit. The DMX address is set electronically using 
the  controls  on  the  front  panel  of  the  unit.  Your 
unit  and  your  DMX  controller  require  a  approved 
DMX-512 110 Ohm Data cable for data input and 
data output (Figure 1). We recommend Accu-Cable DMX cables. If you 

 X-Move LED Plus R 

                                           Set Up

Figure 1

are making your own cables, be sure to use standard 110-120 Ohm 
shielded cable (This cable may be purchased at almost all professional 
sound and lighting stores). Your cables should be made with a male 
and female XLR connector on either end of the cable. Also remember 
that DMX cable must be daisy chained and cannot be split.

 X-Move LED Plus R 

 

 

                       Set Up

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XLR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XLR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Figure 3

1 Ground

1 Ground

XLR Male Socket

XLR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XLR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special Note: Line Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 110-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and 
DATA -). This unit is inserted in the female XLR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

Summary of Contents for X-Move LED Plus R

Page 1: ...l ligent moving head mini LED fixture The X Move LED Plus R can operate as a stand alone fixture or in a Master Slave configuration The X Move LED Plus R has three operating modes a sound active show...

Page 2: ...B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance X Move LED Plus R Safety Precautions American DJ www a...

Page 3: ...MX address is set electronically using the controls on the front panel of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output Figure...

Page 4: ...in a 3 pin DMX line When inserting stan dard 5 pin data cables in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a pr...

Page 5: ...movement angle left to right to left is 160 Tilt movement angle is 90 Show 4 For fixtures fixed to the ceiling or truss The beam is projected at the audience s direction i e in front of the stage Pan...

Page 6: ...nu 2 To activate the Pan inversion tap the UP or DOWN buttons until I is displayed press ENTER to confim To deactivate Pan inversion select No and press Enter I TLT Tilt Inversion 1 Tap the MENU butto...

Page 7: ...t in the chain master will use the female XLR connector only The last unit in the chain will use the male XLR connector only For longer cable runs we suggest a termina tor at the last fixture 2 On the...

Page 8: ...blackout Show Mode This mode allows either a single unit or several units linked together to run one of four shows that you choose 1 Tap the MENU button until SHND is displayed and press ENTER 2 Tap t...

Page 9: ...ructions below and see the figure pictures on the next page Caution Never open the unit when in use Always disconnect the main power before attempting to change the gobos 1 To change the gobo you must...

Page 10: ...fixture operates I e smoke fog residue dust dew In heavy club use we recommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp output 1 Use normal glass cleaner and a sof...

Page 11: ...responsibility of American DJ Inc under this warranty shall be limited to the repair of the product or replace ment thereof including parts at the sole discretion of American DJ All products covered b...

Page 12: ...DMX Channels Colors 8 White Gobos 6 Spot 23 8mm 0 2mm thickness 19mm viewable Sound Active Yes Working Position Any Safe Secure Position Warranty 3 Year 1095 days Voltage is preset at the factory and...

Reviews: