background image

ADJ Products, LLC  -  www.adj.com  - Vortex 1200 User Manual Page 6

ADJ Products, LLC  -  www.adj.com  - Vortex 1200 User Manual Page 7

Power Supply:

 The ADJ Vortex 1200 contains a automatic voltage 

switch,  which  will  auto  sense  the  voltage  when  it  is  plugged  into  a 

power source. With this switch there is no need to worry about the cor-

rect power voltage, this unit can be plugged in anywhere.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol used as a form of communication between intelligent fixtures 

and controllers. A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-

els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter-

minals located on all DMX fixtures (most controllers only have a DATA 

“OUT” terminal). 

DMX Linking:

 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a single 

controller, as long as all fixtures and the controller are DMX compli-

ant.  To  ensure  proper  DMX  data  transmission,  when  using  several 

DMX fixtures try to use the shortest cable path possible. The order 

in which fixtures are connected in a DMX line does not influence the 

DMX addressing. For example; a fixture assigned a DMX address of 1 

may be placed anywhere in a DMX line, at the beginning, at the end, 

or anywhere in the middle. When a fixture is assigned a DMX address 

of 1, the DMX controller knows to send DATA assigned to address 1 

to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation):

 

The Vortex 1200 can be controlled via DMX-512 protocol. The Vortex 

1200 4 DMX channel modes; 14 channel mode, 15 channel mode, 17 

channel mode, & 29 channel mode. The DMX address is set on the front 

panel of the Vortex 1200. Your  unit  and  your  DMX  controller  require 

a  approved  DMX-512  110  Ohm  Data  cable  for  data  input  and  data 

output  (Figure  1).  We  recommend  Accu-Cable 

DMX cables. If you are making your own cables, 

be sure to use standard 110-120 Ohm shielded 

cable  (This  cable  may  be  purchased  at  almost 

all professional sound and lighting stores). Your 

cables should be made with a male and female 

XLR connector on either end of the cable. Also 

remember that DMX cable must be daisy chained 

and cannot be split.

  Vortex 1200                                                              Set Up

Figure 1

Screw one clamp via a M12 screw and nut onto the Omega 

holder. Insert the quick-lock fasteners of the Omega holder into 

the respective holes on the bottom of the Vortex 1200. Tighten 

the quick-lock fasteners fully clockwise. Pull the safety-cable 

through the eyehole hook on the bottom of the base and over 

the trussing system or a safe fixation spot. Insert the end in the 

carabine and tighten the safety screw.

NOTICE:

 The suitable enviromental temperature for this light-

ing fixture is between -25˚ C to 45˚ C. Do not place this lighting 

fixture in an enviroment where the temperatures are under or 

above the temperatures stated above. This will allow the fixture 

to run at its best and help prolong the fixture life. 

  Vortex 1200                                                       Installation

Summary of Contents for Vortex 1200

Page 1: ...s or registered trademarks of their respective companies ADJ Products LLC and all affiliated companies hereby dis claim any and all liabilities for property equipment building and electrical damages i...

Page 2: ...is a great piece for nightclubs bars and stage productions This unit can be used as a stand alone unit or in a Master Slave configuration The unit has 3 operating modes show mode sound active and DMX...

Page 3: ...urer See page 32 for cleaning details Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances inclu ding amplifiers that produce heat T...

Page 4: ...knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX Operation The Vortex 1200 can be controlled via DMX 512...

Page 5: ...line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior DMX512 IN 3 PIN XLR UND REMOTE CONTROL INPUT POWER INPUT OUTPUT SOUND REMOTE CONTROL INPUT PO...

Page 6: ...Hold Blackout or Show will be displayed Choose an operating mode you would like the unit to start up in when either power is applied or the DMX signal is lost Blackout If the DMX signal is lost or pow...

Page 7: ...tons to adjust the value Once you have made your adjust ment press ENTER 4 Repeat steps 2 3 until satisfied Vortex 1200 System Menu Vortex 1200 System Menu will automatically go into stand by mode Hol...

Page 8: ...l now be displayed Press MENU to exit Fan Mode With this function you can control the fan operation 1 Press the MENU button until Fan Mode is displayed press ENTER 2 Either Auto Low or High will now b...

Page 9: ...the Male XLR connector is the input and the Female XLR connector is the output The first unit in the chain master will use the female XLR connector only The last unit in the chain will use the male XL...

Page 10: ...ION 8 15 MACRO 1 16 23 MACRO 2 24 31 MACRO 3 32 39 MACRO 4 40 47 MACRO 5 48 55 MACRO 6 56 63 MACRO 7 64 71 MACRO 8 72 79 MACRO 9 80 87 MACRO 10 88 95 MACRO 11 96 103 MACRO 12 104 111 MACRO 13 Vortex 1...

Page 11: ...E RGBW CHANGE 100 109 NOTHING 110 119 EFFECT WHEEL MOTOR RESET 120 199 PAN TILT MOTOR RESET 200 209 ALL MOTOR RESET 210 249 NOTHING 250 255 SOUND ACTIVE Vortex 1200 14 Channel Mode Channel Value Funct...

Page 12: ...20 199 PAN TILT MOTOR RESET 200 209 ALL MOTOR RESET 210 249 NOTHING 250 255 SOUND ACTIVE 15 DIMMER CURVES 0 20 STANDARD 21 40 STAGE 41 60 TV Vortex 1200 15 Channel Mode Channel Value Function 9 EFFECT...

Page 13: ...ACRO 13 150 159 MACRO 14 160 169 MACRO 15 170 179 MACRO 16 180 189 MACRO 17 Vortex 1200 17 Channel Mode Channel Value Function 9 COLOR MACROS 190 199 MACRO 18 200 209 MACRO 19 210 219 MACRO 20 220 229...

Page 14: ...alue Function 14 PAN TILT MACROS 48 55 MACRO 6 56 63 MACRO 7 64 71 MACRO 8 72 79 MACRO 9 80 87 MACRO 10 88 95 MACRO 11 96 103 MACRO 12 104 111 MACRO 13 112 119 MACRO 14 120 127 MACRO 15 128 135 MACRO...

Page 15: ...J Products LLC www adj com Vortex 1200 User Manual Page 27 ADJ Products LLC www adj com Vortex 1200 User Manual Page 28 Channel Value Function 21 COLOR MACROS 140 149 MACRO 13 150 159 MACRO 14 160 169...

Page 16: ...112 119 MACRO 14 120 127 MACRO 15 128 135 MACRO 16 136 143 MACRO 17 144 151 MACRO 18 152 159 MACRO 19 160 167 MACRO 20 168 175 MACRO 21 176 183 MACRO 22 184 191 MACRO 23 192 199 MACRO 24 200 207 MACR...

Page 17: ...d are wired correctly pin 3 is hot on some other DMX devices pin 2 may be hot Also check that all cables are connected to the right connectors it does matter which way the inputs and outputs are conne...

Page 18: ...ction affects the reliability of the product if the product has been repaired or serviced by anyone other than the ADJ Products LLC factory unless prior written authorization was issued to purchaser b...