background image

American DJ

®

  -  www.americandj.com  - Vizi Spot 5R Instruction Manual Page 7

American DJ

®

  -  www.americandj.com  - Vizi Spot 5R Instruction Manual Page 8

The Vizi Spot 5R is fully operational in two different mounting posi-

tions, hanging upside-down from a ceiling or set on a flat level sur-

face. To avoid internal damage to the unit, never mount the unit on 

its side as illustrated above. Be sure this fixture is kept at least 0.5m 

away from any flammable materials (decoration etc.). Always use 

and install the supplied safety cable as a safety measure to prevent 

accidental damage and/or injury in the event the clamp fails (see next 

page). Never use the carrying handles for secondary attachment.

  Vizi Spot 5R 

 

                                      Mounting

When installing the unit, the trussing or area of installation must be 

able to hold 10 times the weight without any deformation. When 

installing the unit must be secured with a secondary safety attach-

ment, e.g. and appropriate safety cable. Never stand directly below 

the unit when mounting, removing, or servicing the unit. 
Overhead mounting requires extensive experience, including calculat-

ing working load limits, installation material being used, and perodic 

safety inspection of all installation material and unit. If you lack these 

qualifications, do not attempt the installation yourself.
These installaiton should be checked by a skilled person once a year.

  Vizi Spot 5R  

       Important Discharge Lamp Warning

This  fixture  is  fitted  with  a  discharge  lamp  which  is 

highly susceptible to damage if improperly handled. 

Never  touch  the  lamp  with  your  bare  fingers  as  the 

oil from your hands will shorten lamp life. Also, never 

move the fixture until the lamps have had ample time 

to cool. Remember, lamps are not covered under war-

ranty conditions.

This unit emits intense UV radiation which is harmful to the eyes and skin. 

The intense luminance of the lamp can cause severe damage to the retina. 

Never operate this unit without it’s covers, these covers have been specially 

designed to shield against UV radiation.
Epileptic Warning: Those suffering from epilepsy should avoid looking directly 

into the lamp at all times.
Avoid switching the fixture on and off repeatedly in short intervals as this will 

reduce lamp life and intensity.
To achieve the intensity associated with discharge lamps, these lamps  use gas 

sealed in a high pressure environment to emit a brilliant output. Due to the high 

pressure involved with the construction of the lamp, the lamp may explode 

during prolonged extensive use. This risk is increased with age, added care is 

encouraged when dealing with older lamps. Extreme caution should be used 

when operating this or any fixture fitted with a gas discharge lamp. Never 

open this unit while in use.

VERY IMPORTANT:

 This is for your safety and the life length of the unit.

The Philips® Platinum 5R Discharge lamp has lifetime of 2000 hours. 
When the lamp reaches the 2000 hour mark, the display will begin to flash 

“LAMP”. When the lamp reaches the 2000 hour mark and power is applied, 

the lamp will strobe for 5 mins. and the display will begin to flash “LAMP”. 

You may continue to run the fixture and use the lamp for another 300 hours. 

Once 2300 hours is reached the LCD display will will begin to flash “LAMP”, 

the DMX signal will shut off, and the fixture will go into hibernation status and 

will not move. 
Any fixtures daisy chained to the unit will stay powered on, as long as their 

respective lamp has not reached 2300 hours. The unit will start running again 

once  you  have  replaced  the  lamp  and  cleared  the  LAMP  RUNNING  TIME 

(see top of page 25 “CLMP”). Clear the LAMP RUNNING TIME after you have 

replaced the lamp. See page 53 for lamp replacement instructions.
Warning: DO NOT use this lamp more then 2300 hours. Using the lamp 

any longer then the set life could seriously damage your unit.

Summary of Contents for Vizi Spot 5R

Page 1: ...DJ Vizi Spot 5R Table of Contents Unpacking 3 Introduction 3 Customer Support 3 Safety Precautions 4 Features 5 RDMX 5 Handling Precautions 6 Registration 6 Important Discharge Lamp Warnings 7 Mounti...

Page 2: ...on For Your Own Personal Safety Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit To reduce the risk of electrical shock or fire do not expose this u...

Page 3: ...urchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside of the r...

Page 4: ...to the eyes and skin The intense luminance of the lamp can cause severe damage to the retina Never operate this unit without it s covers these covers have been specially designed to shield against UV...

Page 5: ...zi Spot 5R Tighten the quick lock fasteners fully clockwise Install the second Omega holder Pull the safety cable through the holes on the bottom of the base and over the trussing system or a safe fix...

Page 6: ...ring mounted discharge lamp Be sure to only replace with same type lamp After replacing a lamp be sure the lamp is centered in the reflector See pages 53 54 for details on installing and optimizing re...

Page 7: ...are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male an...

Page 8: ...AST SO M Sound controlled Run as Master VALU D XX D 00 DXXX Display the DMX 512 value of each channel RDIS ON OFF Reverse display CLDI ON OFF Shut off LED display 0 MODE DISP LOCK ON OFF Key Lock OPEN...

Page 9: ...N OFF Reverses the pan RTLT MENU ON OFF Reverses the tilt FINE MENU ON OFF Switch between 8bit coarse and 16bit fine pan tilt movement This also switches the DMX channel mode between 11 channel 8 bit...

Page 10: ...MODE ESC button to return to the main menu When the display is on A001 you can directly press the UP or DN buttons to change the DMX start address TEST MAIN MENU TEST This will test the functions of e...

Page 11: ...Manual Page 22 American DJ www americandj com Vizi Spot 5R Instruction Manual Page 21 button and test the different channels 4 Press MODE ESC to exit PLAY MAIN MENU RUN Run the unit in an Auto mode as...

Page 12: ...main menu 2 Tap the UP button until RESE is displayed press ENTER 3 Tap the UP button until SHTR is displayed press ENTER 4 Press ENTER to reset 5 Press MODE ESC to return to the main menu OTHR When...

Page 13: ...com Vizi Spot 5R Instruction Manual Page 26 American DJ www americandj com Vizi Spot 5R Instruction Manual Page 25 Vizi Spot 5R System Menu CLMP With this function you can clear the running time of t...

Page 14: ...button until DISP is displayed press ENTER 3 Tap the UP button until D ON is displayed press ENTER Vizi Spot 5R System Menu 4 CLDI should now be displayed press ENTER 5 The display will show ON OFF P...

Page 15: ...the UP button to select ON to activate this function or OFF to deactivate this function Vizi Spot 5R System Menu American DJ www americandj com Vizi Spot 5R Instruction Manual Page 30 American DJ www...

Page 16: ...7 Press MODE ESC to return to the main menu DFSE With this function you can restore the factory Vizi Spot 5R System Menu settings of the device All settings will be set back to the default values Any...

Page 17: ...tion to display the Software version of the unit 1 Access the main menu 2 Tap the UP button until SPEC is displayed press ENTER Vizi Spot 5R System Menu 3 Tap the UP button until VER is displayed pres...

Page 18: ...to the main menu RUN With this function you can run your pre made pro Vizi Spot 5R System Menu EDIT This menu item allows you to write a program into the memory EEPROM via the control panel or via th...

Page 19: ...l show C XX XX stands for the channel number displayed If C 01 is displayed you will be editing channel 1 of your selected scene press ENTER once you have found your desired channel You can change the...

Page 20: ...problem with one or more of the motors an error code will flash in the display in the form of XXer XX will represent a function number For example when the display shows 03Er it means there is some t...

Page 21: ...u to create your own programs 5 Follow the instruction on page 20 to set the DMX address 6 For longer cable runs more than a 100 feet use a terminator on the last fixture 7 For help operating in DMX m...

Page 22: ...show or invert the pan and tilt functions in the system menu by following the directions on page 25 Master Slave Operation Sound Active or Auto Program This function will allow you to link up to 16 u...

Page 23: ...ON 60 79 LAMP OFF 80 84 ALL MOTOR RESET 85 87 SCAN MOTOR RESET 88 90 COLOR MOTOR RESET 91 93 GOBO MOTOR RESET 94 96 SHUTTER DIMMER MOTOR RESET 97 99 OTHER MOTOR RESET 100 119 INTERNAL PROGRAM 1 120 13...

Page 24: ...8 128 189 FORWARD RAINBOW EFFECT FAST SLOW 190 193 NO ROTATION 194 255 BACKWARDS RAINBOW EFFECT SLOW FAST 6 GOBOS 0 9 OPEN 10 19 ROTATING GOBO 1 20 29 ROTATING GOBO 2 30 39 ROTATING GOBO 3 40 49 ROTAT...

Page 25: ...HANGE TO ANY POSITION 30 39 COLOR GOBO CHANGE TO ANY POSITION 40 59 LAMP ON 60 79 LAMP OFF 80 84 ALL MOTOR RESET 85 87 SCAN MOTOR RESET 88 90 COLOR MOTOR RESET 91 93 GOBO MOTOR RESET 94 96 SHUTTER DIM...

Page 26: ...to access the gobo wheel Turn the wheel with your hand until you come across the gobo you would like to change 4 You have to remove the individual gobo assembly Using a pair of pliers grab the small...

Page 27: ...then gently turn the lamp clockwise to situate the lamp into the holder and tighten the screws that hold the lamp in place Reassemble in reverse order A B Vizi Spot 5R Cleaning Vizi Spot 5R Trouble Sh...

Page 28: ...cts theretofore manufactured No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicabl...

Reviews: