background image

sound activation or in this case pan/tilt inversion.

Each dip switch has a preset value. A specific DMX address is set by 
combining the dip switches that sum your desired value. For exam-
ple:  To achieve a DMX address of 21, combine dip switches 1, 3, and 
5. Sense dip switch 1 has a value of 1, dip switch 3 has a value of 4, 
and dip switch 5 has a value of 16, the combination of the create a 
DMX value of 21.

Set DMX address 21:         

Set DMX address 201:

Dip-switches #   1 = 1            

 

Dip-switches #   1 = 1

 

 

3 = 4 

 

 

 

             4 = 8

 

 

5 = 16   

             

             7 = 64

 

 

   = 21   

             

       

8 = 128

   

 

      

 

 

 

 

   =  201

Data Cable (DMX Cable) Requirements (For DMX and Master/Slave 
Operation): 

The ScanTron™ can be controlled via DMX-512 protocol. 

The ScanTron™ is a five channel DMX unit. The DMX address is set 
on the bottom panel of the ScanTron.™ Your unit and your DMX con-
troller require a standard 3-pin XlR connector for 
data  input  and  data  output  (Figure  1).  If  you  are 
making your own cables, be sure to use standard 
two  conductor  shielded  cable  (This  cable  may 
be  purchased  at  almost  all  pro  sound  and  light-
ing  stores).  Your  cables  should  be  made  with  a 
male and female XlR connector on either end of 
the cable. Also remember that DMX cable must be 
daisy chained and can not be split.

Figure 1

©

American DJ

®

  -  www.americandj.com  - ScanTron™ Instruction Manual Page 10

©

American DJ

®

  -  www.americandj.com  - ScanTron™ Instruction Manual Page 9

Power Supply:

 Before plugging your unit in, be sure the source volt-

age in your area matches the required voltage for your American DJ

®

 

ScanTron.™ The American DJ

®

 ScanTron

 is available in a 120v and 

220v  version.  Because  line  voltage  may  vary  from  venue  to  venue, 
you should be sure your unit voltages matches the wall outlet voltage 
before attempting to operate you fixture.  

DMX-512:

 DMX is short for Digital Multiplex. This is a universal pro-

tocol  used  as  a  form  of  communication  between  intelligent  fixtures 
and controllers. 

A DMX controller sends DMX data instructions from 

the controller to the fixture. DMX data is sent as serial data that trav-
els from fixture to fixture via the DATA “IN” and DATA “OUT” XlR ter-
minals located on all DMX fixtures (most controllers only have a DATA 
“OUT” terminal). 

DMX Linking: 

DMX is a language allowing all makes and models of 

different manufactures to be linked together and operate from a sin-
gle controller, as long as all fixtures and the controller are DMX com-
pliant.

 To ensure proper DMX data transmission, when using several 

DMX  fixtures  try  to  use  the  shortest  cable  path  possible.  The  order 
in which fixtures are connected in a DMX line does not influence the 
DMX addressing. For example; a fixture assigned a DMX address of 1 
may be placed anywhere in a DMX line, at the beginning, at the end, 
or anywhere in the middle. When a fixture is assigned a DMX address 
of 1, the DMX controller knows to send DATA assigned to address 1 
to that unit, no matter where it is located in the DMX chain.

Dip-switches in DMX mode:

 This unit uses dip switches to assign a 

DMX address. Each dip switch represents a binary value. 
Dip Switch 1 address equals 1 

 

Dip Switch 2 address equals 2 

 

Dip Switch 3 address equals 4 

 

Dip Switch 4 address equals 8 
Dip Switch 5 address equals 16 

 

Dip Switch 6 address equals 32
Dip Switch 7 address equals 64 

 

Dip Switch 8 address equals 128
Dip Switch 9 address equals 256

Dip  Switch  10  -  Some  unit  omit  dip  switch  10,  when  a  unit  does 
included dip switch 10 it is usually used for special functions such as 

 ScanTron™  

 

 

 

     

             Set Up

 ScanTron™  

 

 

 

     

             Set Up

ON

1

9

8

7

6

5

4

3

2

10

128

2

8     32  

256

65

16

4

1

SF

DMX CHANNEL

Notice:

 Be sure to follow figures two and three when making your own 

cables. Do not use the ground lug on the XlR connector. Do not con-
nect the cable’s shield conductor to the ground lug or allow the shield 
conductor to come in contact with the XlR’s outer casing. Grounding 
the shield could cause a short circuit and erratic behavior.

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 2

Summary of Contents for ScanTron

Page 1: ...t or when used in multiples linked in a master slave configuration the optional IRC 1 controller may be used The optional controller will access dif ferent programs and control a blackout function For...

Page 2: ...broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from m...

Page 3: ...damage the PC board and void your manufactures warranty 6 XLR Output Jack This jack is used to transmit the incoming DMX signal to another DMX fixture or transmit a Master Slave signal to the nest Sc...

Page 4: ...or on the last fixture ScanTron Operation American DJ www americandj com ScanTron Instruction Manual Page 8 American DJ www americandj com ScanTron Instruction Manual Page 7 ScanTron Operation 7 For h...

Page 5: ...at trav els from fixture to fixture via the DATA IN and DATA OUT XLR ter minals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all ma...

Page 6: ...breaker button in until you hear it pop back in to place If the breaker continues to pop stop using the unit and contact our customer support team the unit may need to be returned for service ScanTron...

Page 7: ...nd 1 Low frequencies bass should cause the unit to react to sound Tapping on the microphone quiet or high pitched sounds may not activate the unit 2 Be sure the sensitivity knob 5 is not set to the mi...

Page 8: ...230v Duty Cycle None DMX 5 Channels Sound Active Yes Working Position Any Safe Secure Position Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Specific...

Reviews: