background image

©

American DJ

®

  -  www.americandj.com  - ScanTron™ Instruction Manual Page 15

This chart list the DMX dip switch setting for DMX address 1 through 
511.  Follow  the  instructions  below  to  configure  fixture  dip  switches 
with your desired DMX address.

 ScanTron™  

 

 

        DMX Dip Switch Chart

Model:  

 

 

 

ScanTron™

Voltage*:

 

 

 

 

120v/60Hz or 220v/50Hz

Lamp:

  

 

 

 

ll-ElC, 24v/250w

Dimensions: 

 

 

 

21.1”(H) x 7.87”(W) x 6.1”(D)

 

 

 

 

 

536mm x 200mm x 155mm

Colors:

 

 

 

 

11 Plus White

Gobos:

 

 

 

 

14, Plus Spot

Weight:

 

 

 

 

25 lbs.

Breaker:

 

 

 

 

6.3A(120v) / 5A (230v)

Duty Cycle:

   

 

 

None

DMX: 

 

 

 

 

5 Channels

Sound Active:

 

 

 

Yes

Working  Position:

   

 

Any Safe, Secure Position

Warranty:

 

 

 

 

1 Year (365 days)

*Voltage is preset at the factory and is not user selectable

Please Note:

 Specifications and improvements in the design 

of this unit and this manual are subject to change without any 
prior written notice.

 ScanTron™  

 

 

                     Specifications

©American DJ Supply

American DJ World Headquarters:

6122 S. Eastern Ave. los Angeles, CA 90040 USA

Tel: 323-582-2650 / Fax: 323-582-2610

Web: www.americandj.com / E-mail: [email protected]

American DJ Europe

Junostraat 2

6468 EW Kerkrade

Netherlands

[email protected] / www.americandj.eu

Tel: +31 45 546 85 00 / Fax: +31 45 546 85 99

Summary of Contents for ScanTron

Page 1: ...t or when used in multiples linked in a master slave configuration the optional IRC 1 controller may be used The optional controller will access dif ferent programs and control a blackout function For...

Page 2: ...broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from m...

Page 3: ...damage the PC board and void your manufactures warranty 6 XLR Output Jack This jack is used to transmit the incoming DMX signal to another DMX fixture or transmit a Master Slave signal to the nest Sc...

Page 4: ...or on the last fixture ScanTron Operation American DJ www americandj com ScanTron Instruction Manual Page 8 American DJ www americandj com ScanTron Instruction Manual Page 7 ScanTron Operation 7 For h...

Page 5: ...at trav els from fixture to fixture via the DATA IN and DATA OUT XLR ter minals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all ma...

Page 6: ...breaker button in until you hear it pop back in to place If the breaker continues to pop stop using the unit and contact our customer support team the unit may need to be returned for service ScanTron...

Page 7: ...nd 1 Low frequencies bass should cause the unit to react to sound Tapping on the microphone quiet or high pitched sounds may not activate the unit 2 Be sure the sensitivity knob 5 is not set to the mi...

Page 8: ...230v Duty Cycle None DMX 5 Channels Sound Active Yes Working Position Any Safe Secure Position Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Specific...