background image

  ScanTron™         

                                         Lamp Replacement

©

American DJ

®

  -  www.americandj.com  - ScanTron™ Instruction Manual Page 11

©

American DJ

®

  -  www.americandj.com  - ScanTron™ Instruction Manual Page 12

Caution:

 

Always replace with the exact same type lamp, unless oth-

erwise  specified  by  an  authorized  American  DJ

®

  service  technician. 

Replacing  with  anything  other  than  the  specified  part  can  damage 
your unit and will void your manufactures warranty.

Warning: 

If you continue to blow lamps or the breaker, STOP using 

the unit. Contact customer support for further instructions, you may 
have to return the unit for servicing. Continuing to use the unit may 
cause serious damage.

Lamp  Replacement:

 

Caution!  Never  attempt  to  change  the  lamp 

while  the  fixture  is  plugged  in.  Always  disconnect  the  main  power 
and allow the unit ample time to cool before attempting to replace the 
lamp. lamp replacement has been made simple by incorporating the 
use of a flip-up front cover that is retained by thumb screws.
1.   Be  sure  to  follow  the  proper  handling  procedures  that  deal  with  
 

halogen lamps.

2.   Remove  the  thumb  screw  on  the  rear  of  the  unit  that  holds  the  
 

lamp socket assembly cover in place.

3.   After  removing  the  thumb  screw,  slide  out  the  cover  from  the  rear  
 

of the unit to expose the lamp socket assembly.

4.  Carefully remove the old lamp and discard it in the trash.
5.  Replace the lamp with an exact match and reassemble in reverse 
 

order.

This  unit  is  equipped  with  a  built-in  safety  breaker.  This  breaker  is 
designed to close the power circuit in the event of an internal short 
or power surge. This will reduce the risk of electrical shock or fire and 
protect the circuitry. To reset the breaker, push the breaker button in 
until  you  hear  it  “pop”  back  in  to  place.  If  the  breaker  continues  to 
pop, stop using the unit and contact our customer support team, the 
unit may need to be returned for service.

 ScanTron™  

 

 

 

     

             Set Up

Figure 3

1 Ground

1 Ground

XlR Male Socket

XlR Pin Configuration

3 Hot

2 Cold

2 Cold

3 Hot

XlR Female Socket

Pin 3 = Data True (positive)

Pin 2 = Data Compliment (negative)

Pin 1 = Ground

Special  Note:  Line  Termination.

 

When  longer  runs  of  cable  are 

used, you may need to use a terminator on the last unit to avoid erratic 
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XlR connector (DATA + and 
DATA -). This unit is inserted in the female XlR connector of the last 
unit in your daisy chain to terminate the line. Using a cable terminator 
(ADJ  part  number  Z-DMX/T)  will  decrease  the  possibilities  of  erratic 
behavior. 

DMX512 IN

3-PIN XLR

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

SOUND

REMOTE

CONTROL

INPUT

POWER

INPUT OUTPUT

DMX512

DMX+,DMX-,COMMON

1

2

3

Termination reduces signal errors and

avoids  signal  transmission  problems

and interference. It is always advisable

to connect a DMX terminal, (Resistance

120 Ohm 1/4 W) between PIN 2 (DMX-)

and PIN 3 (DMX +) of the last fixture.

1

2

3

1

2

3

DMX +

DMX -

COMMON

DMX512 OUT

3-PIN XLR

Figure 4

5-Pin XLR DMX Connectors.

 

Some manufactures use 5-pin XlR 

connectors for DATA transmission in place of 3-pin. 5-pin XlR fixtures 
may be implemented in a 3-pin XlR DMX line. When inserting stan-
dard 5-pin XlR connectors in to a 3-pin line a cable adaptor must be 
used, these adaptors are readily available at most electric stores. The 
chart below details a proper cable conversion.

Conductor

5-Pin XlR Male (In)

3-Pin XlR Female (Out)

Pin 1

Pin 5 - Do Not Use

Pin 4 - Do Not Use

Pin 3

Pin 2

Pin 1

Pin 3

Pin 2

Not Used

Not Used

Data True (+ signal)

Data Compliment (- signal)

Ground/Shield

3-Pin XLR to 5-Pin XLR Conversion

  ScanTron™         

                                                  Breaker Reset

Summary of Contents for ScanTron

Page 1: ...t or when used in multiples linked in a master slave configuration the optional IRC 1 controller may be used The optional controller will access dif ferent programs and control a blackout function For...

Page 2: ...broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from m...

Page 3: ...damage the PC board and void your manufactures warranty 6 XLR Output Jack This jack is used to transmit the incoming DMX signal to another DMX fixture or transmit a Master Slave signal to the nest Sc...

Page 4: ...or on the last fixture ScanTron Operation American DJ www americandj com ScanTron Instruction Manual Page 8 American DJ www americandj com ScanTron Instruction Manual Page 7 ScanTron Operation 7 For h...

Page 5: ...at trav els from fixture to fixture via the DATA IN and DATA OUT XLR ter minals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all ma...

Page 6: ...breaker button in until you hear it pop back in to place If the breaker continues to pop stop using the unit and contact our customer support team the unit may need to be returned for service ScanTron...

Page 7: ...nd 1 Low frequencies bass should cause the unit to react to sound Tapping on the microphone quiet or high pitched sounds may not activate the unit 2 Be sure the sensitivity knob 5 is not set to the mi...

Page 8: ...230v Duty Cycle None DMX 5 Channels Sound Active Yes Working Position Any Safe Secure Position Warranty 1 Year 365 days Voltage is preset at the factory and is not user selectable Please Note Specific...

Reviews: