background image

©

American DJ

®

  -  www.americandj.com - Green Phantom™ Instruction Manual Page 11

©

American DJ

®

  -  www.americandj.com - Green Phantom™ Instruction Manual Page 12

Power Supply:

 This unit is available only in 120v. Before plugging 

your  unit  in  be  sure  the  source  voltage  in  your  area  matches  the 
required voltage for your American DJ

®

 Green Phantom™. 

General Operation:

 

This fixture is designed to operate as a stand 

alone,  sound-active  unit,  or  in  a  Master/Slave  configuration.  It  can 
also  operate  via  DMX  controller.  The  Green  Phantom™  is  ready  to 
be  plugged  in  out  of  the  box.  The  unit  comes  with  several  built-in 
patterns  that  automatically  cycle  through  when  the  unit  is  operat-
ing, the patterns can also be selected manually. If the unit does not 
turn on after the unit has been plugged in, be sure the unit is properly 
plugged in to a matching wall outlet. If the problem continues to per-
sist, please contact customer support for further instructions.

Operating Modes:

Universal DMX Control: 

This mode allows you to use a universal 

DMX-512  controller  such  as  the  American  DJ

®

  DMX  Operator™  or 

Show Designer.™ 
1.  To control your fixture in DMX mode, follow the set-up procedures  
 

on pages 8 - 10 as well as the set-up procedures included with

 

your DMX controller. 

2.  For longer cable runs (more than a 100 feet) use a terminator on  
 

the last fixture.

3.  Assign a DMX address to the unit by following DMX setup and  
 

using dipswitches 1-10.

4.  The Green Phantom™ uses two DMX channels. See page 13   
 

for detailed description of the DMX traits. Use your DMX control- 

 

ler to activate the various built-in patterns.

5.  For help operating in DMX mode consult the manual included   
 

with your DMX controller.

Stand-Alone Operation (Auto Mode, Manual Mode & Sound 
Active  Mode):

 

This  mode  allows  a  single  unit  to  run  in  an  auto 

mode, manual mode, or sound active mode. Use these modes when 
running a single unit, or when running several units as individuals.

Auto Mode:

1.  Set the mode switch to the “Auto” position. Adjust the Elapse
 

Time knob to set the speed of pattern switches. 

  Green Phantom™  

 

 

    

       Operation

  Green Phantom™  

 

 

 

        Operation

Manual Mode:

1.  Set the mode switch to the “Manual” position. Use the Pattern  
 

knobs 1 & 2 to adjust the patterns. Stop adjusting when you find  

 

your desired pattern.

Sound Active Mode:

1.  Set the mode switch to the “Sound Active” position.
2.  The unit will react to the low frequencies of music via the internal 
 

 microphone. 

Master-Slave Operation (Auto Mode, Manual Mode & Sound 
Active Mode): 

This mode will allow you to link up to 16 units together 

and operate without a controller. In Master-Slave operation one unit 
will act as the controlling unit and the others will react to the controlling 
units programs. Any unit can act as a Master or as a Slave.
1.   Using standard XLR microphone cables, daisy chain your units  
 

together via the XLR connector on the rear of the units. Remem- 

 

ber the Male XLR connector is the input and the Female XLR    

 

connector is the output. For longer cable runs we suggest a    

 

terminator at the last fixture.

2. 

Auto Mode:

 Choose a unit to function as the Master and set dip- 

 

switch #1 to the “ON” position, and put the Mode switch in “Auto”  

 

 position. This unit must be the first unit in line.  

3.   Turn any other dipswitches to the “ON” position, except dip-   
 

switch #1, this must remain “OFF” on the SLAVE units. Now they  

 

will react the same as the MASTER.

4. 

Manual Mode:

 Choose a unit to function as the Master and set  

 

dipswitch #1 to the “ON” position, and put the Mode switch in   

 

“Manual” position. This unit must be the first unit in line.  

5.   Turn any other dipswitches to the “ON” position, except dip-   
 

switch #1, this must remain “OFF” on the SLAVE units. Now they  

 

will react the same as the MASTER.

6. 

Sound Active Mode:

 Choose a unit to function as the Master and  

 

set dipswitch #1 to the “ON” position, and put the Mode switch in  

 

“Sound Active” position. This unit must be the first unit in line.  

7.   Turn any other dipswitches to the “ON” position, except dip-   
 

switch #1, this must remain “OFF” on the SLAVE units. Now they  

 

will react the same as the MASTER.

Summary of Contents for Green Phantom

Page 1: ...in a manual mode or a auto mode These modes can also be used in a Master Slave configuration The unit can also be controlled via DMX controller For best results use fog or special effects smoke to en...

Page 2: ...r indoor use only use of this product out doors voids all warranties During long periods of non use disconnect the unit s main power Always mount this unit in safe and stable matter Power cords should...

Page 3: ...n it is not legal to aim Class 3R lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first rea...

Page 4: ...trollers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a sin gle controller as long as all...

Page 5: ...erference It is always advisable to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture 1 2 3 1 2 3 DMX DMX COMMON DMX512 OUT 3 PIN XLR Figure 2 Green P...

Page 6: ...iduals Auto Mode 1 Set the mode switch to the Auto position Adjust the Elapse Time knob to set the speed of pattern switches Green Phantom Operation Green Phantom Operation Manual Mode 1 Set the mode...

Page 7: ...in the instruction manual D This is not a service contract and this warranty does not include maintenance cleaning or periodic check up During the period specified above American DJ Inc will replace d...

Page 8: ...s Fuse 2 Amp Duty Cycle None Warranty 90 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Green Phanto...

Reviews: