background image

 

 

 

 

 

 

 

 

 

   

SD-436R 

                 
                  USER’S MANUAL 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
VER. : 1.0      2012 
 
 
 
 
 
 

Summary of Contents for SD-436R

Page 1: ...SD 436R USER S MANUAL VER 1 0 2012...

Page 2: ...sign 3 3 Technical Data 4 3 1 Technical Parameters of the High speed Dome 4 4 Installation Guide 5 4 1 Installation Preparation 5 4 2 Structure 5 4 3 Installation Size 6 4 4 Installation Procedures 6...

Page 3: ...finishing the installation 3 Dismantlement Please don t dismantle the devices in the dome body Only the professional personnel authorized can operate the maintenance 4 Internal Environment Keep metal...

Page 4: ...arm triggering the alarm can trigger preset auto scan cruising and pattern tours functions 2 2Integrated Universal Speed Change Rotator Delicate stepping motor stable sensitive and accurate 360 contin...

Page 5: ...tible Pan Rotation 0 01 300 s Tilt Rotation 0 01 150 s Pan Tilt Accuracy 0 07 Preset Speed 500 s Pan Angle 360 Continuously Tilt Angle 90 Size 364 x 350 x 202mm Weight 5 6kg Preset Positions 220 Auto...

Page 6: ...System Internal External V Lock Lens 3 4mm 122 4mm 1 6 F4 5 Zoom 1152X 36X Optical 32X Digital S N Ratio 50dB Mini Illumination Color 0 5lux B W 0 2lux Color DSS 0 001lux B W DSS 0 0004lux White Bala...

Page 7: ...6 4 2 Structure 4 3 Installation Size...

Page 8: ...d can bear 4 times the weight of the dome camera itself 1 Bore 4 holes by using templates included on the wall 2 Mount 4 expansion screws into the holes 3 Put the cables through the bracket Fix the do...

Page 9: ...base 7 To lock the dome body to the dome base line up the A and B tabs on the dome body with the A and B label on the dome base Push in on the tabs Insert one side and then the other side Continue pu...

Page 10: ...9 with the dome cover 8 Fix the dome cover with screws 9 Cable Connection 5 Settings 5 1 Interface...

Page 11: ...the dome is installed the communication protocol baud rate and dome address should be confirmed Set the DIP switch keeping the setting consistent with the control system The relative DIP switch site...

Page 12: ...ctory default protocol is PELCO_D Transmission Speed Setting Baud Rate 4 Bit 5 Bit 9600 0 0 4800 1 0 2400 0 1 PRESET 1 1 Dome Address Setting PELCO P Address Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7...

Page 13: ...SD Menu Setting 6 1 Operation Method of the Menu The user can call upon preset position 95 to enter the setting interface of the OSD menu After entering the setting menu a row of information will be d...

Page 14: ...xample 1 In status as the previous picture showed the user press Iris open to enter BACKLIGHT setting 1 BACKLIGHT ON OFF 2 Press Focus in out to select wanted item 3 And then press Iris open to preser...

Page 15: ...14...

Page 16: ...ET 01 CALL SET DELETE BACK EXIT PRESET NO 001 A1 PRESET NO Move the cursor to PRESET NO press the key IRIS OPEN key on control keyboard to enter the edition mode of preset No move the joystick upward...

Page 17: ...t number Then press IRIS OPEN to confirm B1 TITLE Move the cursor to TITLE and press IRIS OPEN to enter the edition mode of scan title C1 START MOVE the cursor to START and press IRIS OPEN to start th...

Page 18: ...C1 D1 E1 BACK EXIT A1 SEQ NO Move the cursor to SEQ NO and press the key IRIS OPEN key on control keyboard to enter the edition mode of sequence No move the joystick upward and downward to select numb...

Page 19: ...uence b When the is on the item PRESET move the joystick upward and downward to select the preset NO you want to add in the sequence c When the is on the item INS move the joystick upward and downward...

Page 20: ...o confirm E1 DELETE Move the cursor to DELETE and press IRIS OPEN to delete the current pattern E ZONES MOTION SEQUENCE PATTERN ZONES TIMING ACTION AUTO TRACKING BACK EXIT SCAN PRESET ZONES BACK EXIT...

Page 21: ...the sentence PRESS IRIS OPEN TO CONFIRM will appear on the screen Move the joystick and press IRIS OPEN to confirm F1 DELETE Press IRIS OPEN to delete the current zone F TIMING ACTION TIMING ACTION A1...

Page 22: ...schedule to other 6 days in a week G1 BACK Go back to upper menu G AUTO TRACKING MOTION SCAN SEQUENCE PATTERN ZONES TIMING ACTION AUTO TRACKING PRESET AUTO TRACKING SENSITIVITY 06 FRAME RATE MID BACK...

Page 23: ...DEFAULTS HELP EXIT MAIN MENU DISPLAY SETUP H A IDLE ACTION IDLE ACTION TIME 3 0 SEC ACTION NO ACTION BACK EXIT A1 B1 DOME SETTINGS IDLE ALARM AUX PRIVACY MASK CLOCK PASSWORD OTHERS BACK EXIT DOME TIT...

Page 24: ...ate all the relative settings and displayed data B1 INPUT STATE Move the cursor to INPUT STATE press IRIS OPEN to set the current state of alarm input as open or close C1 ALARM MODE Move the cursor on...

Page 25: ...THERS DOME TITLE BACK EXIT BACK EXIT Move the cursor to open or close the AUX D PRIVACY MASK DOME SETTINGS IDLE ALARM AUX PRIVACY MASK CLOCK PASSWORD OTHERS DOME TITLE BACK EXIT A1 B1 PRIVACY MASK ENA...

Page 26: ...f the monitor Move joystick upward downward leftward and rightward to adjust the size of privacy zone D1 DELETE Press IRIS OPEN to delete the current privacy zone E CLOCK DOME SETTINGS IDLE ALARM AUX...

Page 27: ...nu G DOME TITLE DOME SETTINGS IDLE ALARM AUX PRIVACY MASK CLOCK PASSWORD OTHERS DOME TITLE BACK EXIT A1 B1 DOME TITLE SET INPUT _ _ _ _ _ _ _ _ CAPS A B C D E F G H I J K L M N O P Q R S T U V W X Y Z...

Page 28: ...t freeze function When the dome is shifting from one preset to another the image on the monitor will not change until the preset calling is done C1 AUTO FLIP Move the cursor to AUTO FLIP and press IRI...

Page 29: ...on to make the image bright D IMAGE FREEZE E ZOOM SPEED LOW NORMAL HIGH F DAY NIGHT AUTO BW COLOR G ADVANCED CAMERA SETTING AUTO FOCUS OFF DIGITAL ZOOM OFF BACKLIGHT OFF IMAGE FREEZE OFF ZOOM SPEED LO...

Page 30: ...MMAND LIST N N N N0 0 0 0 Command Command packet Comments 1 Start Auto Scan Call_99 Start Auto Cruising Call_98 Start Pattern Tour Call_97 Stop checking End Presettup Call_96 2 Open Menu Preset_95 or...

Page 31: ...for Scan No N Call_80 Call_N Preset_93 or Preset_93 Preset left boundary for Scan No N Call_80 Call_N Preset_92 or Preset_92 Preset scan speed for scan No N Call_80 Call_N Preset_87 Call_qq 9 Start pa...

Page 32: ...lled 1 4 1 enable fan heater temperature controlled 2 fan temperature controlled heater temperature controlled 3 enable fan heater temperature controlled 4 Close fan close heater 19 Preset focus sensi...

Page 33: ...nnected bad Check it Power on self check has image can t control indicator light does not flicker The machine s address code or baud rate is wrong Reset Protocol wrong Correct it RS485 bus be connecte...

Page 34: ...33 Dome is dirty Change a certified power supply Fan does not rotate Fan is connected wrong Check it For more product information Please visit us at www AmebaCCTV com...

Reviews: