23
scan, sequence or none.
B
.
.
.
.
ALARM
DOME SETTINGS
<IDLE>
<ALARM>
<AUX>
<PRIVACY MASK>
<CLOCK>
<PASSWORD>
<OTHERS>
BACK
EXIT
――――――――――――――
<DOME TITLE>
――――――――――――――
ALARM NO. : 1
INPUT STATE : CLOSE
ALARM MODE : OFF
TRIGGER ACTION : NONE
ALARM OUT : OFF/OUT1/OUT2/ALL
CANCEL TIME : 10SEC
START TIME : 0 0 : 0 0
STOP TIME : 0 0 : 0 0
ALARM SETTING
A1
B1
C1
D1
E1
F1
G1
H1
BACK
EXIT
A1. ALARM NO.
Move the cursor to ALARM NO., press IRIS OPEN to select the channel No. of alarm input. When
the channel No. has been changed, the system will update all the relative settings and displayed
data.
B1. INPUT STATE
Move the cursor to INPUT STATE, press IRIS OPEN to set the current state of alarm input as open
or close.
C1. ALARM MODE
Move the cursor on ALARM MODE to set the current mode of alarm as ON, OFF and AUTO.
D1. TRIGGER ACTION
Move the cursor on TRIGGER ACTION to set the action type triggered by alarm, such as presets,
sequence, pattern and scan.
E1. ALARM OUT
Move the cursor to ALARM OUT to select the alarm output channel.
F1. CANCEL TIME
Move the cursor to CANCEL TIME to set the duration of the alarm state.
G1. START TIME
START TIME means the time for opening the alarm when the alarm mode is auto.
H1. STOP TIME
Summary of Contents for SD-436R