3049B AUTOMATIC BUTT DISCARD LUBRICATION SYSTEM
OPERATOR’S MANUAL
P A G E |
9
5. Operation
Prior to Getting Started
•
Be sure that all hoses are connected to the appropriate fittings and tightly secured.
•
Put enough fluid in the reservoir to allow the system to operate.
•
Securely connect an air source to the main air inlet and energize the air line
connected to the system.
Operating the System Shutoff Valve
•
Observe Spray Pressure [
B
] is 0 psi when the System Shutoff valve [
A
] is closed.
•
Open System Shutoff valve[
A
] and set the Spray Pressure Regulator [
B
] to 40 psi.
Setting & Operating the Reservoir Pump
•
Open the Pump Shutoff valve [
G
] and set Pump Inlet Pressure [
F
] to at least 50 psi.
•
Open the Fluid Recirculation Valve [
H
] so that the pump cycles approximately once
every two seconds.
Setting the 202 Nozzle
•
Confirm that the 202 Dial [
I
] is set to four rotations from fully closed.
•
Confirm that the Needle Valve [
J
] on the 202 nozzle is set to 3 rotations from fully
closed and then tighten the set screw.
Setting Nozzle Blow Out Pressure
•
Manually actuate the air Blow Out Valve (front valve) [
D
] and set the Blow Out
Pressure Regulator [
E
] to 20 psi.
F
D
B
G
H
I
J
E
C
A