SD4840EK User Manual
D
ISTRIBUTED
C
LOCK
- SYNC0 S
ETUP
103
4.4 Set CFG_word1 Value to Enable SYNC0
Continuing from step 4.3...
1) Click on the “CoE - Online” tab in the settings window.
2) Expand the 8010:0 tree to see the value of the 8010:02 register. (CFG_word1 value)
3) This value must have bit 6 set to enable the synchronous mode in the SD4840EK. If this value is greater
than or equal to 64, then the bit is set and you are finished with this step of the procedure. If the value is
less than 64, then the bit is not set. This new value must be specified in the Startup tab in order to make the
change permanent.
4) Click on the “Startup” tab.
5) Right click on the blank surface and
select “Add New Item...” in the resulting
pop up menu.
6) Click on the [+] button next to the
8010:0 Index field to expand it.
7) Double click on the 8010:02 field. This
opens a dialog that will allow you to set
the field with a decimal or hexadecimal
value. If setting in decimal, the new
value is the present value from step 3 +
64.
8) Click the [OK] button in the dialog box
to set the new value.
9) Click the [OK] button in the Edit
CANopen Startup Entry screen to
accept the new startup parameter
setting.
Figure T4.5 Set DC_Sync Bit in Configuration Word 1
Summary of Contents for SD4840EK
Page 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S310...
Page 6: ...TABLE OF CONTENTS SD4840EK User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Page 38: ...MOVE PROFILES SD4840EK User Manual ADVANCED MICRO CONTROLS INC 38 Notes...
Page 48: ...CALCULATING MOVE PROFILES SD4840EK User Manual ADVANCED MICRO CONTROLS INC 48 Notes...
Page 78: ...COMMAND DATA FORMAT SD4840EK User Manual ADVANCED MICRO CONTROLS INC 78 Notes...
Page 94: ...INSTALLING THE SD4840EK SD4840EK User Manual ADVANCED MICRO CONTROLS INC 94 Notes...
Page 104: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...