1.
Park the implement on a horizontal surface.
2.
Remove the peripheral cover screws
1
.
3.
Remove the cover with ventilation pipe
2
.
4.
If the spur gears
3
are not halfway covered
with transmission fluid in the spur gear trough,
refill oil according to the technical data.
5.
Install the cover with the ventilation pipe.
6.
Install the peripheral cover screws.
7.
Check the second spur gear trough.
NOTE
There is no need to change the oil in the spur
gear trough.
CMS-I-00003087
9.1.10 Changing the oil of the manual transmission
INTERVAL
After the first 50 operating hours
Every 500 operating hours
ENVIRONMENTAL INFORMATION
Danger due to escaping oil
Collect any escaping oil.
Dispose of oil removal material in an
environmentally friendly manner.
1.
Place a suitable container below the oil drain
opening.
2.
Remove the refill screw
1
.
3.
Remove the oil drain plug
2
.
4.
Clean the chip catching magnets on the oil drain
plug.
5.
Install the oil drain plug with a new sealing ring.
CMS-I-00003039
CMS-T-00004135-A.1
9 | Repairing the machine
Maintaining the machine
MG6750-EN-II | C.1 | 21.07.2021