8 Trouble-shooting
91 of 124
Amarex KRT
A B C D E Possible cause
Remedy
-
✘
-
-
-
Dry installation:
Suction lift is too high, NPSHavailable
(positive suction head) is too low.
Check the inlet line for clogging, clean if necessary;
fully open the shut-off element in the inlet line.
✘
-
-
-
-
Pump sets without cooling system
(installation type S):
The temperature control device for
monitoring the winding has tripped due to
high winding temperature.
The motor will restart automatically once it has
cooled down.
✘
-
-
-
- The thermistor tripping unit with manual
reset for temperature limiter has tripped the
pump as a result of the permissible winding
temperature being exceeded.
Have cause determined and eliminated by
qualified and trained personnel.
Pump sets with cooling system:
Check the coolant level.
✘
-
-
-
- Motor has been tripped
by leakage monitor.
Have cause determined and eliminated by
qualified and trained personnel.
✘
-
-
-
- Mechanical seal monitor has tripped.
Have cause determined and eliminated by
qualified and trained personnel.
✘
-
-
-
- Bearing temperature monitor has tripped.
Have cause determined and eliminated by
qualified and trained personnel.