background image

 

WARRANTY

Amantii Imports Corp. (“Amantii”) warrants that your newly purchased Amantii electric fireplace is free from manufacturing and material defects 
for a period of one (1) year from the date of the first purchase, subject to the conditions and limitations contained below.

Warranty Application & Exclusions

This limited warranty applies to your newly purchased Amantii electric fireplace; the limited warranty's application is limited to purchases made in 
any province of Canada or in any of the 52 States of the United States of America, including the District of Columbia.  Only the original purchaser 
of the product is eligible for coverage under this limited warranty; the warranty is not transferable.

Products excluded from this limited warranty 

Light bulbs are not covered by this limited warranty and are the sole responsibility of the owner/purchaser.

Warranty Coverage and Term

Products covered by this limited warranty have been tested and inspected prior to shipment and, subject to the provisions of this warranty, 
Amantii warrants such products to be free from defects in material and workmanship for a period of one (1) year from the date of the first 
purchase of such products.

The limited one (1) year warranty period for products also applies to any implied warranties that may exist under applicable law.  Some 
jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to the purchaser.

All other warranties—expressed or implied—with respect to the product, its components and accessories or any obligation/liabilities on the part 
of Amantii are hereby expressly excluded. 

Limitations to Coverage Under Limited Warranty

This limited warranty does not apply to products that have been repaired, except by Amantii or its authorized service representatives, or 
otherwise altered.  This limited warranty further does not apply to defects resulting from misuse, abuse, accident, neglect, incorrect installation, 
improper maintenance or handling, or operation with an incorrect power source. Products made by other manufacturers, sold with the product 
or thereafter, are not covered by this limited warranty. The use of unauthorized components will render this warranty null and void.

Panorama Outdoor Units

All Panorama units that are installed outdoors or in moisture intense conditions must use the stainless steel cover. Proof of purchase of the cover 
is required for any warranty claims. 

Service Under Limited Warranty

Defects must be brought to the attention of Amantii Technical Service by contacting Amantii at (1-888-406-8764), or at 1503 – 7088 18th Avenue, 
Burnaby, British Columbia, Canada, V3N 0A2.  Please have your proof of purchase, catalogue/model and serial numbers available when calling; 
any and all service under the limited warranty requires a proof of purchase of the product.

Defects

Should a product or part covered by this limited warranty be proven to be defective, in material or workmanship, and during the one (1) year 
limited warranty period, Amantii will replace such defective product or part without charge.  If Amantii is unable to replace such product, or if 
replacement is not commercially practicable or cannot be timely done, in its sole discretion Amantii may, in lieu of replacement, choose to refund 
the purchase price for such product or part.

Limitations

In no event will Amantii, including without limitation any of its directors, officers, shareholders, employees, consultants, agents, heirs, executors, 
administrators and assigns, be liable to the purchaser or any third party, whether in contract, in tort, or on any other basis for any indirect, special, 
punitive, exemplary, consequential, or incidental loss, cost or damage arising out of or in connection with the sale, maintenance, use or inability 
to use the product, even if Amantii, including without limitation any of its directors, officers, shareholders, employees, consultants, agents, heirs, 
executors, administrators and assigns, have been advised of the possibility of such losses, costs or damages, or if such losses, costs or damages 
are foreseeable.  In no event will Amantii, including without limitation any of its directors, officers, shareholders, employees, consultants, agents, 
heirs, executors, administrators and assigns, be liable for any direct losses, costs or damages that exceed the purchase price of the product.

Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not 
apply to the purchaser.

Application of Provincial and State Law

This limited warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to jurisdiction.  The provisions 
of the United Nations Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by 
this limited warranty.

General

Amantii reserves the right to make changes at any time without notice, in design, material, specifications, prices and the right to discontinue 
styles and products.

Revised July 2015

Summary of Contents for ZECL-31-3228-STL

Page 1: ...n these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE ...

Page 2: ...m your Amantii product IMPORTANT INSTRUCTIONS 3 UNPACKING AND TESTING APPLIANCE 4 GROUNDING APPLIANCE 4 LOCATING THE FIREPLACE 4 CLEARANCES WHEN BUILT IN 5 ZECL 31 3228 STL 6 INSTALLATION OVERVIEW ZERO CLEARANCE METAL FIREPLACES 9 HARD WIRE INSTALLATION 10 MEDIA OPTIONS 11 DECORATIVE MEDIA INSTALLATION 11 OPERATION 12 MANUAL OPERATION 12 REMOTE CONTROL OPERATION 13 INSTALLING WALL THERMOSTAT 14 RE...

Page 3: ...ation or exhaust opening as this may cause an electric shock fire or damage to the heater 10 To prevent a possible fire do not block air intakes in any manner 11 A heater has hot and arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored 12 Use this heater only as described in this manual Any other use not recommended by the manufacturer...

Page 4: ... adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should not be used if a three slot grounded receptacle is available To disconnect appliance turn controls to off then remove plug from outlet LOCATING THE FIREPLACE Plan where to locate and frame the fireplace This will save time and money later when you install the fireplace Before installation con...

Page 5: ...pliance and front glass It may be placed directly on wood or a non combustible surface not on linoleum or carpet The minimum clearance from the top of the appliance to a mantel combustible or non combustible is 2 50 8 mm The sides and back must maintain 1 25 4mm clearance to any material The top must maintain a 3 8 10mm clearance to any material ...

Page 6: ... This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes In the absence of local codes us the current CSA C22 1 Canadian Electri...

Page 7: ...7 Square Surround ZECL 31 3228 STL SQR Arch Surround ZECL 31 3228 STL ARCH ...

Page 8: ...e suitable rain cap A Code Conforming jacketed grounded receptacle may be placed within the fireplace Do not place it above the fireplace insert The surround glass extends 1 below the base of the insert Attach the This fireplace has been altered plate to the fireplace use two screws or other suitable method You may wish to place it in a location where it will be covered by the surround glass on th...

Page 9: ... bolts to provide adequate leveling Silicone The surround glass extends 1 below the base of the insert A Code Conforming jacketed grounded receptacle may be placed within the fireplace Do not place it above the fireplace insert Leveling Bolts Attach the This fireplace has been altered plate to the fireplace use two screws or other suitable method You may wish to place it in a location where it wil...

Page 10: ... be electrically connected and grounded in accordance with local codes if hard wired In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI NFPA 70 NATIONAL ELECTRICAL CODE in the United States 1 Remove the cover plate from the left side of the appliance by removing the two screws as shown below Unscrew and remove power cord 2 Attach the wiri...

Page 11: ...screws both hand side to take off the front glass The log is shipped in place The log has tabs on each side that hold it secure There are two screws to fix the side panel Unscrew the screws to remove the side panels Remove both side panels to remove the log set Screw back the side panels after remove the log set Installing the decorative media Pour the decorative media into the tray Feel free to u...

Page 12: ...e goes above 25 the heater will be turned off and the cycle will continue The LED indicator will be PURPLE in colour under this mode 4 Flame effect Press the button marked Flame to adjust the flame brightness The flame brightness will cycle through Low Medium High OFF NOTE If operated at the Low heat setting the fireplace will not provide as much heat output as in the High heat setting however the...

Page 13: ...is will turn off all the functions and the fireplace will be in standby mode DISPLAY ON OFF button Switching the fireplace flame and tray light ON OFF It has functions of setting memory DISPLAY BLUE button Adjust the blue color brightness of flame DISPLAY YELLOW button Adjust the yellow color brightness of flame DISPLAY ORANGE button Adjust the orange color brightness of flame HEATER ON OFF button...

Page 14: ...rmostat prior to installing the fireplace WALL THERMOSTAT WIRING 24 VAC Install Wall Thermostat per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left up side of appliance 3 Pull the wire out and cut the inside thermostat Connect the wires to the wall thermostat as shown below Follow instructions provided with wall s...

Page 15: ...32B CONTROL PANEL 1 7 10104010 REMOTE RECEIVER 1 8 359006B BACK GLASS 1 9 601136B 601137B FLAME LED STRIP 1 10 10702138B BOTTOM GLASS 1 11 3059019 RIGHT BRACKET 1 12 10101225 FLICKER MOTOR 1 13 3059502 FLICKER ASSEMBLY 1 14 3085020 FLICKER ASSEMBLY SUPPORT BRACKET 1 15 601136B 601137B TRAY LED STRIP 1 16 3059005 LEFT BRACKET 1 17 10701138B FRONT GLASS 1 18 10105064 REMOTE 1 ...

Page 16: ...16 EXPLODED VIEW ...

Page 17: ...use has blown Replace the fuse Appliance is not plugged into an electrical outlet Check plug and plug in Appliance has overheated and safety device has caused the thermal switch to disconnect Turn off the main switch allow appliance to cool for 10 minutes then turn it on Appliance will not come on when switch is flipped to ON Circuit board is burnt out Inspect the circuit board and replace it if n...

Page 18: ...18 SERVICE HISTORY This heater must be serviced annually depending on usage Date Dealer Name Service technician Name Service Performed Special Concerns NOTES ...

Page 19: ...any warranty claims Service Under Limited Warranty Defects must be brought to the attention of Amantii Technical Service by contacting Amantii at 1 888 406 8764 or at 1503 7088 18th Avenue Burnaby British Columbia Canada V3N 0A2 Please have your proof of purchase catalogue model and serial numbers available when calling any and all service under the limited warranty requires a proof of purchase of...