19
LP Fuel Cylinder
This machine uses the 20 lb (9.1 kg) capacity cylinder,
which meets the D.O.T. 4E240 standards. These
cylinders are also listed by UL. In addition, the steel
cylinder meets European TPED specifications and
is CE compliant. Filling should be done ONLY by a
qualified propane dealer. A properly filled cylinder
should not exceed 80% of the rated capacity. Do not
overfill the cylinder or use a liquid withdraw cylinder on
the machine. The use of a liquid withdraw cylinder on
a vapor withdraw system could freeze the regulator and
create a fire hazard.
Installing the LP Cylinder
1. Before bringing a propane cylinder indoors, always
check it for over-filling.
CAUTION!
Always connect or change cylinders in a
well ventilated area.
2. Place the tank on the machine and secure with the
retaining strap. Remove slack by pulling on the
loose end of the strap and secure back to strap.
3. Connect the fuel hose coupling to the service valve
by turning clockwise (
“HAND TIGHTEN ONLY”).
Make sure coupling is not cross threaded and check
for leakage by noting any propane odors immediately
after cylinder is connected.
NOTE:
It is sometimes easier to install if the connection
to the service valve is made before strapping the
cylinder in place.
CAUTION!
Always open service valve slowly to allow
pressure to equalize in hoses. Opening quickly may
cause the flow check valve to engage, limiting fuel flow.
4. To remove the cylinder, reverse procedure.
Liquid Level
Sight Gauge
Service
Valve
Bleeder
Valve
Pressure
Relief Valve
Only Use a Vapor Cylinder!
Summary of Contents for Pioneer Eclipse 440ST
Page 1: ...Propane Stripping Machine PE440ST Operator s Manual...
Page 2: ......
Page 30: ...Electrical Schematic with SafeSense 30...
Page 31: ...31 Electrical Schematic without SafeSense...
Page 32: ...32 Connections with SafeSense...
Page 34: ...Connections without SafeSense 34...
Page 48: ...Transport Cart Assembly 48 RF037800 052311 6 5 3 2 4 4 7 1...
Page 50: ......
Page 54: ......
Page 55: ......