43
gB
O P e r at I n g I n s t r U C t I O n s
Upgrade kit
Multi-x
reference:
If the foil does not contact the tool, in spite of repeated
adjustments, this must be readjusted as follows:
example:
Contact missing at the right spherical shell at 3
o‘clock (black), apply foil on the left spherical shell onto the
border of the calibration plate 3‘ (black).
Place the adjusting bar upon it and repeat the adjusting
process with the foil laid underneath.
10.
OPeratIOn anD hanDlIng
OF Blank FOrMs anD
FastenIng Plates
10.1
InsertIng the FastenIng Plate anD
Blank FOrMs IntO the MOUntIng
Plates
Insert the temporary mold together with the retaining plate
and the blank form into the respective mounting plate and fix
it with the locking levers.