![Amana SB520T Service Download Page 45](http://html1.mh-extra.com/html/amana/sb520t/sb520t_service_2917731045.webp)
April 1998
47
RS5290000 Rev. 0
Service Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge
capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be
connected. Ensure all earth wires are connected before certifying unit as repaired and/or operational.
Restrictions
Symptoms
Restrictions in sealed system most often occur at
capillary tube or filter drier, but can exist anywhere on
liquid side of system.
Restrictions reduce refrigerant flow rate and heat
removal rate. Wattage drops because compressor is
not circulating normal amount of refrigerant.
Common causes of total restrictions are moisture,
poorly soldered joints, or solid contaminants. Moisture
freezes at evaporator inlet end of capillary tube. Solid
contaminants collect in filter drier.
If restriction is on low side, suction pressure will be in a
vacuum and head pressure will be near normal
If restriction is on high side, suction pressure will be in
a vacuum and head pressure will be higher than
normal during pump out cycle.
Refrigeration occurs on low pressure side of partial
restriction. There will be a temperature difference at
the point of restriction. Frost and/or condensation will
be present in most case at the point of restriction.
Also, system requires longer to equalize.
Slight or partial restriction can give the same
symptoms as refrigerant shortage including lower than
normal back pressure, head pressure, wattage, and
warmer temperatures.
Total restriction on the discharge side of compressor
when restriction is between compressor and first half
of condenser results in higher than normal head
pressure and wattage while low side is being pumped
out.
Testing for Restrictions
To determine if a restriction exists:
1.
Attach gauge and manifold between suction and
discharge sides of sealed system.
2.
Turn unit on and allow pressure on each side to
stabilize. Inspect condenser side of system.
Tubing on condenser should be warm and
temperature should be equal throughout (no
sudden drops at any point along tubing).
• If temperature of condenser tubing is consistent
throughout, go to step 4.
• If temperature of condenser tubing drops suddenly
at any point, tubing is restricted at point of
temperature drop (if restriction is severe, frost may
form at point of restriction and extend down in
direction of refrigerant flow in system). Go to step 5.
3.
Visually check system for kinks in refrigeration line
which is causing restriction. Correct kink and
repeat step 2.
4.
Turn unit off and time how long it takes high and
low pressure gauges to equalize:
• If pressure equalization takes longer than 10
minutes, a restriction exists in the capillary tube or
drier filter. Go to step 5.
• If pressure equalization takes less than 10 minutes,
system is not restricted. Check for other possible
causes of malfunction.
5.
Recover refrigerant in sealed system.
NOTE: Before opening any refrigeration system,
capture refrigerant in system for safe disposal.
6.
Remove power from unit.
CAUTION
!
To reduce risk of personal injury or property damage,
take necessary precautions against high temperatures
required for brazing.
7.
Remove and replace restricted device.
8.
Evacuate sealed system.
9.
Charge system to specification.
NOTE: Do not use captured or recycled refrigerant in
Amana units. Captured or recycled refrigerant
voids any Amana and/or compressor
manufacturer's warranty.
NOTE: Charge system with exact amount of refrigerant.
See Technical Sheet or refer to unit nameplate
for correct refrigerant charge. Inaccurately
charged system will cause future problems.