THERMOSTAT* CONNECTIONS TO RH-HEAT PUMPS
WITH INDOOR BBA/BBC BLOWER COIL
Approved Thermostats: 10636701, 10636702, 10636703, D9945804, D9807605
NOTE: 1. When installing accessories, wiring may have to be modified. Follow the instructions
in the accessory kit’s installation instructions.
2. For thermostat models D9945804 and D9807605, jumper Y and W1 at the thermostat.
WARNING
To avoid personal injury, shock or death, disconnect the
electrical power before electrically connecting any
equipment or changing any existing wiring.
R
C/X Y O W2 E G
(1)
(1)
Room Thermostat
BBA/BBC Blower
(RH**B*A) Outdoor
Heat Pump
R C Y O W2 E G
R C Y O W