December 1997
61
RS1300003 Rev. 0
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge
capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be
connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.
!
WARNING
Cabinet Components
Refrigerator Temperature Control
1.
Remove control knobs (nonelectronic models).
2.
Loosen bracket on bottom left of cover to allow
cover to be rotated forward.
3.
Pull bottom of cover out until it unsnaps. Continue
tilting cover out until top tabs release and remove
cover.
4.
Remove insulation over top of damper.
5.
Remove styrofoam filler piece from control body
exposing two mounting screws.
6.
Remove mounting screws to remove control.
Thermistor
Air Duct
Gasket
Spacer
Air Duct
Clamp
Damper
Gasket
Insulation
Damper
Control
Damper
Control
Insert
Damper
Front
Gasket
Control
Cover
Electronic Models Temperature Control
Freezer Temperature Control (Nonelectronic Models)
1.
Remove control knobs.
2.
Loosen brace on bottom left of cover to allow
cover to be rotated forward.
3.
Pull bottom of cover out until it unsnaps. Continue
tilting cover out until top tabs release and remove
cover.
4.
Remove two control mounting screws.
5.
Remove sealer from control capillary well.
NOTE: Replace sealer during reassembly.
6.
Pull control out of bracket.
7.
Disconnect wiring from rear of control.
8.
Remove capillary from well and remove control.
Control
Knob s
Freezer
Control
Control Cover
Bracket
Damper
Gasket
Air Duct
Clamp
Space rs
Air Duct
Gasket
Control Cover
Damper
Front
Gasket
Damper Contro l
Insert
Damper Control
Non-electronic Models Temperature Control
Refrigerator Light Switch
1.
Remove two mounting bolts on rear corners of
lens.
2.
Remove two mounting bolts located on front of
shield, behind trim piece.
3.
Remove move two mounting bolts on rear of light
shield and slide shield back until released.
4.
Slide switch mounting plate back until released
from refrigerator top.
5.
Remove wiring to switch.
6.
Press in on tab located on the opposite side of
electrical tabs and push switch through mounting
plate.
Freezer Light/Auger Motor Interlock Switch
1.
Remove two mounting screws from plate.
2.
Slide switch mounting plate back until released.
3.
Remove wiring to switch.
4.
Press in on tabs and push switch through
mounting plate.
Disassembly